J1939 · Electrical
SPN 168 FMI 16
Battery voltage high, moderately severe
What does SPN 168 FMI 16 mean?
System voltage at the ECM is high at the moderately severe level. Overvoltage can damage electronics, so find out why the alternator is over-charging. Urgency: check soon - the machine may derate or limit a function. Check first: measure the charging voltage at the battery with the engine running.
- FMI 16
- Above normal, moderately severe
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Measure the charging voltage at the battery with the engine running
Then 4 more checksWhere to read it
Connect a J1939-capable scan tool to the 9-pin diagnostic port.
Checks
0 of 5 done
Causes
- Alternator regulator fault letting voltage rise
- Poor ground strap on the alternator, so the regulator sees a wrong voltage
- Wrong voltage after a jump start or a battery fitted wrongly
- Battery sense wire fault at the alternator
How it failed
You'll notice: System voltage at the ECM is high at the moderately severe level, which can damage electronics.
Real conditionRead from FMI 16: above normal, moderately severe
The sensor reading is valid but outside the allowed range - the problem may be real.
- Meter test
- Check the real value with a separate gauge or thermometer before blaming the sensor.
- Good result
- If the gauge agrees with the display, fix the machine, not the sensor.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Other SPN 168 codes
Source
Cummins ISX15 2013-2018 fault codes list (Diesel Laptops)
This list shows SPN 168 with FMI 16. The guidance on this page is general, not taken from it.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.