Detent solenoids hold the boom up, boom down and bucket levers in a set position until the operator pulls them out or a stop position is reached. The MCU drives each solenoid and watches the circuit for a low-voltage or high-current fault.

FaultCheck172-4Hyundai · Boom and bucket lever detent solenoids
Code shows hereFAULT172-4

Where this code shows

Turn the key on and open the fault code or diagnosis menu on the cluster.

What do these codes mean?

Hyundai codes 172-4 to 174-6 are all about the boom and bucket lever detent solenoids. Most are shorted low faults; none needs an immediate stop. Start with this check: measure the detent solenoid coil resistance with the plug off and compare the three solenoids with each other.

How urgent are they?

None of the 6 codes here means stop now; all 6 can wait until the shift ends, but find the cause before the next one.

  • Check soon6

What should I check first?

Measure the detent solenoid coil resistance with the plug off and compare the three solenoids with each other

Shared checks

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Hyundai 172-4Boom up lever detent solenoid circuit voltage below normal, shorted to low source or open

    The MCU finds the Boom up lever detent solenoid circuit voltage low, which it reads as a short to ground or an open circuit on the driver line.· Shorted low
    Check soon

    Causes

    • Open wire or loose pin between the MCU and the boom up detent solenoid
    • Driver wire chafed to ground near the boom up detent solenoid
    • the boom up detent solenoid coil open or shorted

    Checks

    1. 1Unplug the boom up detent solenoid and measure coil resistance: an open reading or a near-zero reading shows which way the coil failed
    2. 2Check the driver wire from the MCU to the boom up detent solenoid for continuity and for a path to ground
    3. 3Push the boom lever to the raise detent and see whether it stays; only this lever should misbehave for this code
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 172-6Boom up lever detent solenoid circuit current above normal

    The MCU measures more current than normal on the Boom up lever detent solenoid circuit, usually a shorted coil or a driver wire touching supply.· Shorted low
    Check soon

    Causes

    • the boom up detent solenoid coil shorted between turns
    • Driver wire touching a supply wire
    • Water in the connector bridging two pins

    Checks

    1. 1Measure the boom up detent solenoid coil resistance against a known-good twin and look for a low reading
    2. 2Inspect the connector for water or corrosion bridging pins, then clear the code and see if it returns at once
    3. 3Push the boom lever to the raise detent and see whether it stays; only this lever should misbehave for this code
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 173-4Boom down lever detent solenoid circuit voltage below normal, shorted to low source or open

    The MCU finds the Boom down lever detent solenoid circuit voltage low, which it reads as a short to ground or an open circuit on the driver line.· Shorted low
    Check soon

    Causes

    • Open wire or loose pin between the MCU and the boom down detent solenoid
    • Driver wire chafed to ground near the boom down detent solenoid
    • the boom down detent solenoid coil open or shorted

    Checks

    1. 1Unplug the boom down detent solenoid and measure coil resistance: an open reading or a near-zero reading shows which way the coil failed
    2. 2Check the driver wire from the MCU to the boom down detent solenoid for continuity and for a path to ground
    3. 3Move the lever into the lower or float detent and check whether the holding magnet grips it
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 173-6Boom down lever detent solenoid circuit current above normal

    The MCU measures more current than normal on the Boom down lever detent solenoid circuit, usually a shorted coil or a driver wire touching supply.· Shorted low
    Check soon

    Causes

    • the boom down detent solenoid coil shorted between turns
    • Driver wire touching a supply wire
    • Water in the connector bridging two pins

    Checks

    1. 1Measure the boom down detent solenoid coil resistance against a known-good twin and look for a low reading
    2. 2Inspect the connector for water or corrosion bridging pins, then clear the code and see if it returns at once
    3. 3Move the lever into the lower or float detent and check whether the holding magnet grips it
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 174-4Bucket lever detent solenoid circuit voltage below normal, shorted to low source or open

    The MCU finds the Bucket lever detent solenoid circuit voltage low, which it reads as a short to ground or an open circuit on the driver line.· Shorted low
    Check soon

    Causes

    • Open wire or loose pin between the MCU and the bucket detent solenoid
    • Driver wire chafed to ground near the bucket detent solenoid
    • the bucket detent solenoid coil open or shorted

    Checks

    1. 1Unplug the bucket detent solenoid and measure coil resistance: an open reading or a near-zero reading shows which way the coil failed
    2. 2Check the driver wire from the MCU to the bucket detent solenoid for continuity and for a path to ground
    3. 3Rack the bucket back to its stop and see whether the lever holds there
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 174-6Bucket lever detent solenoid circuit current above normal

    The MCU measures more current than normal on the Bucket lever detent solenoid circuit, usually a shorted coil or a driver wire touching supply.· Shorted low
    Check soon

    Causes

    • the bucket detent solenoid coil shorted between turns
    • Driver wire touching a supply wire
    • Water in the connector bridging two pins

    Checks

    1. 1Measure the bucket detent solenoid coil resistance against a known-good twin and look for a low reading
    2. 2Inspect the connector for water or corrosion bridging pins, then clear the code and see if it returns at once
    3. 3Rack the bucket back to its stop and see whether the lever holds there
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Measure the detent solenoid coil resistance with the plug off and compare the three solenoids with each other
  2. 2Check the connector at the lever stand for water, corrosion and bent pins
  3. 3Trace the harness from the cab to the lever stand looking for chafing at the hinge points
  4. 4Operate each lever to its detent with the engine off and key on and listen for the click of the solenoid
  5. 5Clear the code and retest; if it returns at once the fault is hard, if it comes and goes suspect the connector

Causes

  • Solenoid coil open or shorted
  • Wire to the solenoid chafed against the loader frame or lever linkage
  • Connector at the lever stand filled with dirt or water
  • MCU driver damaged by a shorted coil

Most codes here: shorted low (6 of 6)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: The lever no longer latches in its detent position, or latches and will not release.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.