Hyundai Fuel level, engine speed and starting aid circuits fault codes

This group holds the fuel level sensor, the engine speed signal and the relays that help starting: engine preheat, fuel warmer and anti-restart. The MCU reads the first two and drives the three relays.

FaultCheck301-3Hyundai · Fuel level, engine speed and starting aid circuits
Code shows hereFAULT301-3

Where this code shows

Turn the key on and open the fault code or diagnosis menu on the cluster.

What do these codes mean?

Hyundai codes 301-3 to 327-6 are all about the fuel level, engine speed and starting aid circuits. Most are shorted low faults; none needs an immediate stop. Start with this check: check the fuse feeding the relay circuit and the relay base for burn marks or loose terminals.

How urgent are they?

None of the 9 codes here means stop now; all 9 can wait until the shift ends, but find the cause before the next one.

  • Check soon9

What should I check first?

Check the fuse feeding the relay circuit and the relay base for burn marks or loose terminals

Shared checks

9 of 9

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Hyundai 301-3Fuel level sensor circuit voltage above normal

    The MCU sees the fuel level sender signal above its normal window, which it reads as a short to a high source or an open wire.· Shorted high
    Check soon

    Causes

    • Fuel sender unplugged or connector corroded at the tank
    • Signal wire open or shorted to supply
    • Sender float arm or resistor failed

    Checks

    1. 1Dip the tank or look at the level and compare it with the gauge to confirm the gauge is wrong
    2. 2Unplug the fuel sender and measure the signal pin with key on to separate a harness fault from a bad sender
    3. 3Inspect the sender connector at the tank for fuel, water or green corrosion
    4. 4Check the wire from the sender to the MCU for continuity along its length
    5. 5Clear the code and watch the gauge move as fuel is added
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Hyundai 301-4Fuel level sensor circuit voltage below normal

    The MCU sees the Fuel level sensor signal pulled down below its normal voltage window, which it reads as a short to ground or a dead supply.· Shorted low
    Check soon

    Causes

    • Signal wire chafed to the frame or to a ground wire near the the fuel level sender
    • the fuel level sender failed internally and pulling its signal low
    • Lost 5 V reference to the part

    Checks

    1. 1Unplug the fuel level sender and measure its 5 V reference pin: no supply means a harness or MCU output problem
    2. 2With the plug off, check the signal wire for continuity to ground along its run toward the MCU
    3. 3Dip or sight the tank and compare it with the gauge, then disconnect the sender to see how the reading moves
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 310-8Engine speed signal error, abnormal frequency or pulse width

    The MCU receives an engine speed signal whose frequency or pulse width is not plausible.· Erratic or implausible
    Check soon

    Causes

    • Speed signal wire damaged near the engine
    • Interference from a nearby power cable
    • Engine speed signal from the engine controller unstable

    Checks

    1. 1Compare the cluster engine rpm with a hand tachometer at idle and at high idle
    2. 2Inspect the speed signal wire and its shield along the route to the MCU
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Hyundai 322-4Engine preheat relay circuit voltage below normal, shorted to low source or open

    The MCU finds the Engine preheat relay circuit voltage low, which it reads as a short to ground or an open circuit on the driver line.· Shorted low
    Check soon

    Causes

    • Open wire or loose pin between the MCU and the engine preheat relay
    • Driver wire chafed to ground near the engine preheat relay
    • the engine preheat relay coil open or shorted

    Checks

    1. 1Unplug the engine preheat relay and measure coil resistance: an open reading or a near-zero reading shows which way the coil failed
    2. 2Check the driver wire from the MCU to the engine preheat relay for continuity and for a path to ground
    3. 3Try a cold start and watch for the preheat indication to come on and time out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 322-6Engine preheat relay circuit current above normal

    The MCU measures more current than normal on the Engine preheat relay circuit, usually a shorted coil or a driver wire touching supply.· Shorted low
    Check soon

    Causes

    • the engine preheat relay coil shorted between turns
    • Driver wire touching a supply wire
    • Water in the connector bridging two pins

    Checks

    1. 1Measure the engine preheat relay coil resistance against a known-good twin and look for a low reading
    2. 2Inspect the connector for water or corrosion bridging pins, then clear the code and see if it returns at once
    3. 3Try a cold start and watch for the preheat indication to come on and time out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 325-4Fuel warmer relay circuit voltage below normal, shorted to low source or open

    The MCU finds the Fuel warmer relay circuit voltage low, which it reads as a short to ground or an open circuit on the driver line.· Shorted low
    Check soon

    Causes

    • Open wire or loose pin between the MCU and the fuel warmer relay
    • Driver wire chafed to ground near the fuel warmer relay
    • the fuel warmer relay coil open or shorted

    Checks

    1. 1Unplug the fuel warmer relay and measure coil resistance: an open reading or a near-zero reading shows which way the coil failed
    2. 2Check the driver wire from the MCU to the fuel warmer relay for continuity and for a path to ground
    3. 3Feel or measure whether the fuel warmer heats when the relay is commanded on
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 325-6Fuel warmer relay circuit current above normal

    The MCU measures more current than normal on the Fuel warmer relay circuit, usually a shorted coil or a driver wire touching supply.· Shorted low
    Check soon

    Causes

    • the fuel warmer relay coil shorted between turns
    • Driver wire touching a supply wire
    • Water in the connector bridging two pins

    Checks

    1. 1Measure the fuel warmer relay coil resistance against a known-good twin and look for a low reading
    2. 2Inspect the connector for water or corrosion bridging pins, then clear the code and see if it returns at once
    3. 3Feel or measure whether the fuel warmer heats when the relay is commanded on
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 327-4Anti-restart relay circuit voltage below normal, shorted to low source or open

    The MCU finds the Anti-restart relay circuit voltage low, which it reads as a short to ground or an open circuit on the driver line.· Shorted low
    Check soon

    Causes

    • Open wire or loose pin between the MCU and the anti-restart relay
    • Driver wire chafed to ground near the anti-restart relay
    • the anti-restart relay coil open or shorted

    Checks

    1. 1Unplug the anti-restart relay and measure coil resistance: an open reading or a near-zero reading shows which way the coil failed
    2. 2Check the driver wire from the MCU to the anti-restart relay for continuity and for a path to ground
    3. 3Try to crank with the engine running and confirm the starter does not engage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 327-6Anti-restart relay circuit current above normal

    The MCU measures more current than normal on the Anti-restart relay circuit, usually a shorted coil or a driver wire touching supply.· Shorted low
    Check soon

    Causes

    • the anti-restart relay coil shorted between turns
    • Driver wire touching a supply wire
    • Water in the connector bridging two pins

    Checks

    1. 1Measure the anti-restart relay coil resistance against a known-good twin and look for a low reading
    2. 2Inspect the connector for water or corrosion bridging pins, then clear the code and see if it returns at once
    3. 3Try to crank with the engine running and confirm the starter does not engage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Check the fuse feeding the relay circuit and the relay base for burn marks or loose terminals
  2. 2Swap the suspect relay with an identical known-good relay and see whether the code follows
  3. 3Check the fuel sender connector at the tank for fuel or water in the plug
  4. 4Look at the engine speed signal wire where it crosses hot or moving parts
  5. 5Clear the code and retest with key on, then with the engine running

Causes

  • Fuel level sender wiring or float assembly damaged
  • Relay coil, relay base or its connector faulty
  • Engine speed signal wiring chafed near the engine
  • Blown fuse feeding the relay circuit

Most codes here: shorted low (7 of 9)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: The fuel gauge reads empty or full, the engine speed reading looks wrong, or the preheat, fuel warmer or anti-restart function stops working.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.