Hyundai · Excavator pressure sensor codes (HCESPN)

Hyundai Excavator work, travel and pilot input pressure sensors fault codes

These codes cover the working device idle pressure sensor, the travel idle pressure sensor, the boom up pilot pressure sensor and the arm in/out with bucket close pilot pressure sensor. The MCU reads them to see which functions are being asked for.

FaultCheck105-0Hyundai · Excavator work, travel and pilot input pressure sensors
Code shows hereFAULT105-0

Where this code shows

Turn the key on and open the fault code or diagnosis menu on the cluster.

What do these codes mean?

Hyundai codes 105-0 to 133-4 are all about the excavator work, travel and pilot input pressure sensors. Most are lost message faults; none needs an immediate stop. Start with this check: compare the cluster reading with a gauge on the matching pilot or work port.

How urgent are they?

None of the 16 codes here means stop now; all 16 can wait until the shift ends, but find the cause before the next one.

  • Check soon16

What should I check first?

Compare the cluster reading with a gauge on the matching pilot or work port

Shared checks

16 of 16

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Hyundai 105-0Working device idle pressure sensor data above normal range

    The MCU reads the Working device idle pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Lost message
    Check soon

    Causes

    • Real work circuit idle pressure high: stuck pilot or valve spool
    • Open signal or ground wire at the the working device idle pressure sensor connector
    • the working device idle pressure sensor failed and reading high

    Checks

    1. 1Read the Working device idle value on the cluster and compare it with a test gauge on the working device idle circuit before blaming the sensor
    2. 2Unplug the working device idle pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Move a work lever and see whether the reading changes as the auto idle should react
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 105-1Working device idle pressure sensor data below normal range

    The MCU reads the Working device idle pressure sensor below its normal range, so the pressure it expects on the working device idle circuit is not showing up in the signal.· Lost message
    Check soon

    Causes

    • Low real pressure on the working device idle circuit: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at the working device idle pressure sensor
    • the working device idle pressure sensor drifted or failed low

    Checks

    1. 1Compare the cluster Working device idle reading with a mechanical gauge on the working device idle circuit; if the gauge is good the sensor or wiring is at fault
    2. 2Check the the working device idle pressure sensor connector for water or green corrosion that adds resistance to the signal
    3. 3Move a work lever and see whether the reading changes as the auto idle should react
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 105-2Working device idle pressure sensor data error

    The MCU decides the Working device idle pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Lost message
    Check soon

    Causes

    • Intermittent contact in the the working device idle pressure sensor connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • the working device idle pressure sensor failing intermittently

    Checks

    1. 1Watch the Working device idle reading while wiggling the harness at the working device idle pressure sensor; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Move a work lever and see whether the reading changes as the auto idle should react
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 105-4Working device idle pressure sensor circuit voltage below normal

    The MCU sees the Working device idle pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near the working device idle pressure sensor
    • the working device idle pressure sensor shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug the working device idle pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the the working device idle pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Move a work lever and see whether the reading changes as the auto idle should react
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 108-0Travel idle pressure sensor data above normal range

    The MCU reads the Travel idle pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Lost message
    Check soon

    Causes

    • Real travel circuit pressure high: stuck pilot or travel spool
    • Open signal or ground wire at the the travel idle pressure sensor connector
    • the travel idle pressure sensor failed and reading high

    Checks

    1. 1Read the Travel idle value on the cluster and compare it with a test gauge on the travel idle circuit before blaming the sensor
    2. 2Unplug the travel idle pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Move a travel lever and watch the travel idle reading change
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 108-1Travel idle pressure sensor data below normal range

    The MCU reads the Travel idle pressure sensor below its normal range, so the pressure it expects on the travel idle circuit is not showing up in the signal.· Lost message
    Check soon

    Causes

    • Low real pressure on the travel idle circuit: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at the travel idle pressure sensor
    • the travel idle pressure sensor drifted or failed low

    Checks

    1. 1Compare the cluster Travel idle reading with a mechanical gauge on the travel idle circuit; if the gauge is good the sensor or wiring is at fault
    2. 2Check the the travel idle pressure sensor connector for water or green corrosion that adds resistance to the signal
    3. 3Move a travel lever and watch the travel idle reading change
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 108-2Travel idle pressure sensor data error

    The MCU decides the Travel idle pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Lost message
    Check soon

    Causes

    • Intermittent contact in the the travel idle pressure sensor connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • the travel idle pressure sensor failing intermittently

    Checks

    1. 1Watch the Travel idle reading while wiggling the harness at the travel idle pressure sensor; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Move a travel lever and watch the travel idle reading change
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 108-4Travel idle pressure sensor circuit voltage below normal

    The MCU sees the Travel idle pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near the travel idle pressure sensor
    • the travel idle pressure sensor shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug the travel idle pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the the travel idle pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Move a travel lever and watch the travel idle reading change
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 127-0Boom up pilot pressure sensor data above normal range

    The MCU reads the Boom up pilot pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Lost message
    Check soon

    Causes

    • Real boom up pilot pressure high: pilot valve or line fault
    • Open signal or ground wire at the the boom up pilot pressure sensor connector
    • the boom up pilot pressure sensor failed and reading high

    Checks

    1. 1Read the Boom up pilot value on the cluster and compare it with a test gauge on the boom up pilot line before blaming the sensor
    2. 2Unplug the boom up pilot pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Raise the boom with a lever and watch the reading respond
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 127-1Boom up pilot pressure sensor data below normal range

    The MCU reads the Boom up pilot pressure sensor below its normal range, so the pressure it expects on the boom up pilot line is not showing up in the signal.· Lost message
    Check soon

    Causes

    • Low real pressure on the boom up pilot line: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at the boom up pilot pressure sensor
    • the boom up pilot pressure sensor drifted or failed low

    Checks

    1. 1Compare the cluster Boom up pilot reading with a mechanical gauge on the boom up pilot line; if the gauge is good the sensor or wiring is at fault
    2. 2Check the the boom up pilot pressure sensor connector for water or green corrosion that adds resistance to the signal
    3. 3Raise the boom with a lever and watch the reading respond
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 127-2Boom up pilot pressure sensor data error

    The MCU decides the Boom up pilot pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Lost message
    Check soon

    Causes

    • Intermittent contact in the the boom up pilot pressure sensor connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • the boom up pilot pressure sensor failing intermittently

    Checks

    1. 1Watch the Boom up pilot reading while wiggling the harness at the boom up pilot pressure sensor; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Raise the boom with a lever and watch the reading respond
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 127-4Boom up pilot pressure sensor circuit voltage below normal

    The MCU sees the Boom up pilot pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near the boom up pilot pressure sensor
    • the boom up pilot pressure sensor shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug the boom up pilot pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the the boom up pilot pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Raise the boom with a lever and watch the reading respond
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 133-0Arm in/out and bucket close pilot pressure sensor data above normal range

    The MCU reads the Arm in/out and bucket close pilot pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Real condition
    Check soon

    Causes

    • Real arm or bucket pilot pressure high: pilot valve fault
    • Open signal or ground wire at the the arm in/out and bucket close pilot pressure sensor connector
    • the arm in/out and bucket close pilot pressure sensor failed and reading high

    Checks

    1. 1Read the Arm in/out and bucket close pilot value on the cluster and compare it with a test gauge on the arm and bucket pilot line before blaming the sensor
    2. 2Unplug the arm in/out and bucket close pilot pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Move the arm and bucket levers and watch the reading respond
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Hyundai 133-1Arm in/out and bucket close pilot pressure sensor data below normal range

    The MCU reads the Arm in/out and bucket close pilot pressure sensor below its normal range, so the pressure it expects on the arm and bucket pilot line is not showing up in the signal.· Real condition
    Check soon

    Causes

    • Low real pressure on the arm and bucket pilot line: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at the arm in/out and bucket close pilot pressure sensor
    • the arm in/out and bucket close pilot pressure sensor drifted or failed low

    Checks

    1. 1Compare the cluster Arm in/out and bucket close pilot reading with a mechanical gauge on the arm and bucket pilot line; if the gauge is good the sensor or wiring is at fault
    2. 2Check the the arm in/out and bucket close pilot pressure sensor connector for water or green corrosion that adds resistance to the signal
    3. 3Move the arm and bucket levers and watch the reading respond
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Hyundai 133-2Arm in/out and bucket close pilot pressure sensor data error

    The MCU decides the Arm in/out and bucket close pilot pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Erratic or implausible
    Check soon

    Causes

    • Intermittent contact in the the arm in/out and bucket close pilot pressure sensor connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • the arm in/out and bucket close pilot pressure sensor failing intermittently

    Checks

    1. 1Watch the Arm in/out and bucket close pilot reading while wiggling the harness at the arm in/out and bucket close pilot pressure sensor; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Move the arm and bucket levers and watch the reading respond
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Hyundai 133-4Arm in/out and bucket close pilot pressure sensor circuit voltage below normal

    The MCU sees the Arm in/out and bucket close pilot pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near the arm in/out and bucket close pilot pressure sensor
    • the arm in/out and bucket close pilot pressure sensor shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug the arm in/out and bucket close pilot pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the the arm in/out and bucket close pilot pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Move the arm and bucket levers and watch the reading respond
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Compare the cluster reading with a gauge on the matching pilot or work port
  2. 2Check each sensor connector for water and corrosion
  3. 3Inspect the harness along the control valve for rubbing
  4. 4Measure sensor supply and ground at the plug with key on
  5. 5Swap two identical sensors if available and see whether the fault follows the sensor

Causes

  • Sensor connector damaged on the control valve or pilot line
  • Pilot pressure low or high because of a real hydraulic fault
  • Failed sensor
  • Weak 5 V supply

Most codes here: lost message (9 of 16)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: Auto idle, travel or boom and arm operation may act oddly, and the cluster shows an HCESPN number from 105 to 133.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.