Hyundai · Excavator pressure sensor codes (HCESPN)
Hyundai Excavator work, travel and pilot input pressure sensors fault codes
These codes cover the working device idle pressure sensor, the travel idle pressure sensor, the boom up pilot pressure sensor and the arm in/out with bucket close pilot pressure sensor. The MCU reads them to see which functions are being asked for.
Where this code shows
Turn the key on and open the fault code or diagnosis menu on the cluster.
What do these codes mean?
Hyundai codes 105-0 to 133-4 are all about the excavator work, travel and pilot input pressure sensors. Most are lost message faults; none needs an immediate stop. Start with this check: compare the cluster reading with a gauge on the matching pilot or work port.
How urgent are they?
None of the 16 codes here means stop now; all 16 can wait until the shift ends, but find the cause before the next one.
- Check soon16
What should I check first?
Compare the cluster reading with a gauge on the matching pilot or work port
Shared checks16 of 16
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Hyundai 105-0Working device idle pressure sensor data above normal range
The MCU reads the Working device idle pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It tells the MCU that a work function is being operated for auto idle. Auto idle depends on this signal, so a bad value leaves the engine stuck at working speed after the levers go neutral or lets it drop to idle while you are still digging. Check the logic by leaving the levers in neutral for a few seconds and seeing whether engine speed drops to auto idle as the sensor value falls. Also confirm the work lever pilot lines are free of leaks. Cracked pilot hose, worn shuttle valve, or sticky spool in the work manifold can also give a lazy value.· Lost messageLost messageCheck soonCauses
- Real work circuit idle pressure high: stuck pilot or valve spool
- Open signal or ground wire at the the working device idle pressure sensor connector
- the working device idle pressure sensor failed and reading high
Checks
- 1Read the Working device idle value on the cluster and compare it with a test gauge on the working device idle circuit before blaming the sensor
- 2Unplug the working device idle pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Move a work lever and see whether the reading changes as the auto idle should react
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 105-1Working device idle pressure sensor data below normal range
The MCU reads the Working device idle pressure sensor below its normal range, so the pressure it expects on the working device idle circuit is not showing up in the signal. It tells the MCU that a work function is being operated for auto idle. Auto idle depends on this signal, so a bad value leaves the engine stuck at working speed after the levers go neutral or lets it drop to idle while you are still digging. Check the logic by leaving the levers in neutral for a few seconds and seeing whether engine speed drops to auto idle as the sensor value falls. Also confirm the work lever pilot lines are free of leaks. Cracked pilot hose, worn shuttle valve, or sticky spool in the work manifold can also give a lazy value.· Lost messageLost messageCheck soonCauses
- Low real pressure on the working device idle circuit: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at the working device idle pressure sensor
- the working device idle pressure sensor drifted or failed low
Checks
- 1Compare the cluster Working device idle reading with a mechanical gauge on the working device idle circuit; if the gauge is good the sensor or wiring is at fault
- 2Check the the working device idle pressure sensor connector for water or green corrosion that adds resistance to the signal
- 3Move a work lever and see whether the reading changes as the auto idle should react
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 105-2Working device idle pressure sensor data error
The MCU decides the Working device idle pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It tells the MCU that a work function is being operated for auto idle. Auto idle depends on this signal, so a bad value leaves the engine stuck at working speed after the levers go neutral or lets it drop to idle while you are still digging. Check the logic by leaving the levers in neutral for a few seconds and seeing whether engine speed drops to auto idle as the sensor value falls. Also confirm the work lever pilot lines are free of leaks. Cracked pilot hose, worn shuttle valve, or sticky spool in the work manifold can also give a lazy value.· Lost messageLost messageCheck soonCauses
- Intermittent contact in the the working device idle pressure sensor connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- the working device idle pressure sensor failing intermittently
Checks
- 1Watch the Working device idle reading while wiggling the harness at the working device idle pressure sensor; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Move a work lever and see whether the reading changes as the auto idle should react
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 105-4Working device idle pressure sensor circuit voltage below normal
The MCU sees the Working device idle pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It tells the MCU that a work function is being operated for auto idle. Auto idle depends on this signal, so a bad value leaves the engine stuck at working speed after the levers go neutral or lets it drop to idle while you are still digging. Check the logic by leaving the levers in neutral for a few seconds and seeing whether engine speed drops to auto idle as the sensor value falls. Also confirm the work lever pilot lines are free of leaks. Cracked pilot hose, worn shuttle valve, or sticky spool in the work manifold can also give a lazy value.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near the working device idle pressure sensor
- the working device idle pressure sensor shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug the working device idle pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the the working device idle pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
- 3Move a work lever and see whether the reading changes as the auto idle should react
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 108-0Travel idle pressure sensor data above normal range
The MCU reads the Travel idle pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It tells the MCU that travel is being used for auto idle. Travel detection depends on this signal, so a bad value can leave travel alarms or auto idle acting wrongly while the machine is still moving. Check the logic by driving a short distance, then stopping, and seeing whether the travel signal drops away and the engine returns to idle. Also confirm the travel pedal pilot lines are free of leaks. Leaky travel shuttle, worn pilot valve, or damp connector at the travel manifold are the usual suspects. Compare against the sibling sensors fed from the same 5 V reference.· Lost messageLost messageCheck soonCauses
- Real travel circuit pressure high: stuck pilot or travel spool
- Open signal or ground wire at the the travel idle pressure sensor connector
- the travel idle pressure sensor failed and reading high
Checks
- 1Read the Travel idle value on the cluster and compare it with a test gauge on the travel idle circuit before blaming the sensor
- 2Unplug the travel idle pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Move a travel lever and watch the travel idle reading change
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 108-1Travel idle pressure sensor data below normal range
The MCU reads the Travel idle pressure sensor below its normal range, so the pressure it expects on the travel idle circuit is not showing up in the signal. It tells the MCU that travel is being used for auto idle. Travel detection depends on this signal, so a bad value can leave travel alarms or auto idle acting wrongly while the machine is still moving. Check the logic by driving a short distance, then stopping, and seeing whether the travel signal drops away and the engine returns to idle. Also confirm the travel pedal pilot lines are free of leaks. Leaky travel shuttle, worn pilot valve, or damp connector at the travel manifold are the usual suspects. Compare against the sibling sensors fed from the same 5 V reference.· Lost messageLost messageCheck soonCauses
- Low real pressure on the travel idle circuit: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at the travel idle pressure sensor
- the travel idle pressure sensor drifted or failed low
Checks
- 1Compare the cluster Travel idle reading with a mechanical gauge on the travel idle circuit; if the gauge is good the sensor or wiring is at fault
- 2Check the the travel idle pressure sensor connector for water or green corrosion that adds resistance to the signal
- 3Move a travel lever and watch the travel idle reading change
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 108-2Travel idle pressure sensor data error
The MCU decides the Travel idle pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It tells the MCU that travel is being used for auto idle. Travel detection depends on this signal, so a bad value can leave travel alarms or auto idle acting wrongly while the machine is still moving. Check the logic by driving a short distance, then stopping, and seeing whether the travel signal drops away and the engine returns to idle. Also confirm the travel pedal pilot lines are free of leaks. Leaky travel shuttle, worn pilot valve, or damp connector at the travel manifold are the usual suspects. Compare against the sibling sensors fed from the same 5 V reference.· Lost messageLost messageCheck soonCauses
- Intermittent contact in the the travel idle pressure sensor connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- the travel idle pressure sensor failing intermittently
Checks
- 1Watch the Travel idle reading while wiggling the harness at the travel idle pressure sensor; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Move a travel lever and watch the travel idle reading change
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 108-4Travel idle pressure sensor circuit voltage below normal
The MCU sees the Travel idle pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It tells the MCU that travel is being used for auto idle. Travel detection depends on this signal, so a bad value can leave travel alarms or auto idle acting wrongly while the machine is still moving. Check the logic by driving a short distance, then stopping, and seeing whether the travel signal drops away and the engine returns to idle. Also confirm the travel pedal pilot lines are free of leaks. Leaky travel shuttle, worn pilot valve, or damp connector at the travel manifold are the usual suspects. Compare against the sibling sensors fed from the same 5 V reference.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near the travel idle pressure sensor
- the travel idle pressure sensor shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug the travel idle pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the the travel idle pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
- 3Move a travel lever and watch the travel idle reading change
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 127-0Boom up pilot pressure sensor data above normal range
The MCU reads the Boom up pilot pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It reads boom raise pilot pressure. The boom up pilot reading tells the MCU the operator is raising the boom, so a bad value can leave boom-priority or power-boost logic stuck on or off during lifting. Check the logic by raising the boom against light load and watching the pilot value rise cleanly from near zero. Also confirm the boom pilot line has no trapped air after service. Check the pilot valve plunger and its seals, because worn seals bleed pilot oil to tank and flatten the reading.· Lost messageLost messageCheck soonCauses
- Real boom up pilot pressure high: pilot valve or line fault
- Open signal or ground wire at the the boom up pilot pressure sensor connector
- the boom up pilot pressure sensor failed and reading high
Checks
- 1Read the Boom up pilot value on the cluster and compare it with a test gauge on the boom up pilot line before blaming the sensor
- 2Unplug the boom up pilot pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Raise the boom with a lever and watch the reading respond
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 127-1Boom up pilot pressure sensor data below normal range
The MCU reads the Boom up pilot pressure sensor below its normal range, so the pressure it expects on the boom up pilot line is not showing up in the signal. It reads boom raise pilot pressure. The boom up pilot reading tells the MCU the operator is raising the boom, so a bad value can leave boom-priority or power-boost logic stuck on or off during lifting. Check the logic by raising the boom against light load and watching the pilot value rise cleanly from near zero. Also confirm the boom pilot line has no trapped air after service. Check the pilot valve plunger and its seals, because worn seals bleed pilot oil to tank and flatten the reading.· Lost messageLost messageCheck soonCauses
- Low real pressure on the boom up pilot line: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at the boom up pilot pressure sensor
- the boom up pilot pressure sensor drifted or failed low
Checks
- 1Compare the cluster Boom up pilot reading with a mechanical gauge on the boom up pilot line; if the gauge is good the sensor or wiring is at fault
- 2Check the the boom up pilot pressure sensor connector for water or green corrosion that adds resistance to the signal
- 3Raise the boom with a lever and watch the reading respond
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 127-2Boom up pilot pressure sensor data error
The MCU decides the Boom up pilot pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It reads boom raise pilot pressure. The boom up pilot reading tells the MCU the operator is raising the boom, so a bad value can leave boom-priority or power-boost logic stuck on or off during lifting. Check the logic by raising the boom against light load and watching the pilot value rise cleanly from near zero. Also confirm the boom pilot line has no trapped air after service. Check the pilot valve plunger and its seals, because worn seals bleed pilot oil to tank and flatten the reading.· Lost messageLost messageCheck soonCauses
- Intermittent contact in the the boom up pilot pressure sensor connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- the boom up pilot pressure sensor failing intermittently
Checks
- 1Watch the Boom up pilot reading while wiggling the harness at the boom up pilot pressure sensor; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Raise the boom with a lever and watch the reading respond
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 127-4Boom up pilot pressure sensor circuit voltage below normal
The MCU sees the Boom up pilot pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It reads boom raise pilot pressure. The boom up pilot reading tells the MCU the operator is raising the boom, so a bad value can leave boom-priority or power-boost logic stuck on or off during lifting. Check the logic by raising the boom against light load and watching the pilot value rise cleanly from near zero. Also confirm the boom pilot line has no trapped air after service. Check the pilot valve plunger and its seals, because worn seals bleed pilot oil to tank and flatten the reading.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near the boom up pilot pressure sensor
- the boom up pilot pressure sensor shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug the boom up pilot pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the the boom up pilot pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
- 3Raise the boom with a lever and watch the reading respond
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 133-0Arm in/out and bucket close pilot pressure sensor data above normal range
The MCU reads the Arm in/out and bucket close pilot pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It reads the pilot pressure used for arm and bucket close. This sensor reads the combined arm and bucket close pilot signal, so a bad value shows up during digging cycles when the MCU expects those levers to be active. Check the logic by closing the bucket and moving the arm in and out and watching whether this pilot value changes with each lever. Also confirm the arm and bucket pilot lines are free of kinks. Check the pilot valve linkage for slop, because a loose lever gives a hesitant, patchy pressure rise. Compare against the sibling sensors fed from the same 5 V reference.· Real conditionReal conditionCheck soonCauses
- Real arm or bucket pilot pressure high: pilot valve fault
- Open signal or ground wire at the the arm in/out and bucket close pilot pressure sensor connector
- the arm in/out and bucket close pilot pressure sensor failed and reading high
Checks
- 1Read the Arm in/out and bucket close pilot value on the cluster and compare it with a test gauge on the arm and bucket pilot line before blaming the sensor
- 2Unplug the arm in/out and bucket close pilot pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Move the arm and bucket levers and watch the reading respond
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Hyundai 133-1Arm in/out and bucket close pilot pressure sensor data below normal range
The MCU reads the Arm in/out and bucket close pilot pressure sensor below its normal range, so the pressure it expects on the arm and bucket pilot line is not showing up in the signal. It reads the pilot pressure used for arm and bucket close. This sensor reads the combined arm and bucket close pilot signal, so a bad value shows up during digging cycles when the MCU expects those levers to be active. Check the logic by closing the bucket and moving the arm in and out and watching whether this pilot value changes with each lever. Also confirm the arm and bucket pilot lines are free of kinks. Check the pilot valve linkage for slop, because a loose lever gives a hesitant, patchy pressure rise. Compare against the sibling sensors fed from the same 5 V reference.· Real conditionReal conditionCheck soonCauses
- Low real pressure on the arm and bucket pilot line: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at the arm in/out and bucket close pilot pressure sensor
- the arm in/out and bucket close pilot pressure sensor drifted or failed low
Checks
- 1Compare the cluster Arm in/out and bucket close pilot reading with a mechanical gauge on the arm and bucket pilot line; if the gauge is good the sensor or wiring is at fault
- 2Check the the arm in/out and bucket close pilot pressure sensor connector for water or green corrosion that adds resistance to the signal
- 3Move the arm and bucket levers and watch the reading respond
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Hyundai 133-2Arm in/out and bucket close pilot pressure sensor data error
The MCU decides the Arm in/out and bucket close pilot pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It reads the pilot pressure used for arm and bucket close. This sensor reads the combined arm and bucket close pilot signal, so a bad value shows up during digging cycles when the MCU expects those levers to be active. Check the logic by closing the bucket and moving the arm in and out and watching whether this pilot value changes with each lever. Also confirm the arm and bucket pilot lines are free of kinks. Check the pilot valve linkage for slop, because a loose lever gives a hesitant, patchy pressure rise. Compare against the sibling sensors fed from the same 5 V reference.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the the arm in/out and bucket close pilot pressure sensor connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- the arm in/out and bucket close pilot pressure sensor failing intermittently
Checks
- 1Watch the Arm in/out and bucket close pilot reading while wiggling the harness at the arm in/out and bucket close pilot pressure sensor; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Move the arm and bucket levers and watch the reading respond
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Hyundai 133-4Arm in/out and bucket close pilot pressure sensor circuit voltage below normal
The MCU sees the Arm in/out and bucket close pilot pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It reads the pilot pressure used for arm and bucket close. This sensor reads the combined arm and bucket close pilot signal, so a bad value shows up during digging cycles when the MCU expects those levers to be active. Check the logic by closing the bucket and moving the arm in and out and watching whether this pilot value changes with each lever. Also confirm the arm and bucket pilot lines are free of kinks. Check the pilot valve linkage for slop, because a loose lever gives a hesitant, patchy pressure rise. Compare against the sibling sensors fed from the same 5 V reference.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near the arm in/out and bucket close pilot pressure sensor
- the arm in/out and bucket close pilot pressure sensor shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug the arm in/out and bucket close pilot pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the the arm in/out and bucket close pilot pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
- 3Move the arm and bucket levers and watch the reading respond
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Compare the cluster reading with a gauge on the matching pilot or work port
- 2Check each sensor connector for water and corrosion
- 3Inspect the harness along the control valve for rubbing
- 4Measure sensor supply and ground at the plug with key on
- 5Swap two identical sensors if available and see whether the fault follows the sensor
Causes
- Sensor connector damaged on the control valve or pilot line
- Pilot pressure low or high because of a real hydraulic fault
- Failed sensor
- Weak 5 V supply
Most codes here: lost message (9 of 16)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: Auto idle, travel or boom and arm operation may act oddly, and the cluster shows an HCESPN number from 105 to 133.
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.