Hyundai · Excavator pressure sensor codes (HCESPN)

Hyundai Excavator pump and control pressure sensors fault codes

These HCESPN codes cover the main pump P1 and P2 pressure sensors, the pilot pump P3 pressure sensor, the overload pressure sensor and the two negative feedback pressure sensors on -9 series excavators. The MCU uses them for pump flow control and engine speed matching.

FaultCheck120-0Hyundai · Excavator pump and control pressure sensors
Code shows hereFAULT120-0

Where this code shows

Turn the key on and open the fault code or diagnosis menu on the cluster.

What do these codes mean?

Hyundai codes 120-0 to 125-4 are all about the excavator pump and control pressure sensors. Most are lost message faults; none needs an immediate stop. Start with this check: compare the cluster reading with a test gauge on the matching pressure port before replacing a sensor.

How urgent are they?

None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.

  • Check soon24

What should I check first?

Compare the cluster reading with a test gauge on the matching pressure port before replacing a sensor

Shared checks

24 of 24

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Hyundai 120-0Main pump P1 pressure sensor data above normal range

    The MCU reads the Main pump P1 pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Lost message
    Check soon

    Causes

    • Real P1 pressure above normal: regulator or relief stuck
    • Open signal or ground wire at the the P1 pump pressure sensor connector
    • the P1 pump pressure sensor failed and reading high

    Checks

    1. 1Read the Main pump P1 value on the cluster and compare it with a test gauge on the P1 pump outlet before blaming the sensor
    2. 2Unplug the P1 pump pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Compare the P1 reading with P2 while working a function: two similar pumps should read similarly
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 120-1Main pump P1 pressure sensor data below normal range

    The MCU reads the Main pump P1 pressure sensor below its normal range, so the pressure it expects on the P1 pump outlet is not showing up in the signal.· Lost message
    Check soon

    Causes

    • Low real pressure on the P1 pump outlet: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at the P1 pump pressure sensor
    • the P1 pump pressure sensor drifted or failed low

    Checks

    1. 1Compare the cluster Main pump P1 reading with a mechanical gauge on the P1 pump outlet; if the gauge is good the sensor or wiring is at fault
    2. 2Check the the P1 pump pressure sensor connector for water or green corrosion that adds resistance to the signal
    3. 3Compare the P1 reading with P2 while working a function: two similar pumps should read similarly
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 120-2Main pump P1 pressure sensor data error

    The MCU decides the Main pump P1 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Lost message
    Check soon

    Causes

    • Intermittent contact in the the P1 pump pressure sensor connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • the P1 pump pressure sensor failing intermittently

    Checks

    1. 1Watch the Main pump P1 reading while wiggling the harness at the P1 pump pressure sensor; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Compare the P1 reading with P2 while working a function: two similar pumps should read similarly
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 120-4Main pump P1 pressure sensor circuit voltage below normal

    The MCU sees the Main pump P1 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near the P1 pump pressure sensor
    • the P1 pump pressure sensor shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug the P1 pump pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the the P1 pump pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Compare the P1 reading with P2 while working a function: two similar pumps should read similarly
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 121-0Main pump P2 pressure sensor data above normal range

    The MCU reads the Main pump P2 pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Lost message
    Check soon

    Causes

    • Real P2 pressure above normal: regulator or relief stuck
    • Open signal or ground wire at the the P2 pump pressure sensor connector
    • the P2 pump pressure sensor failed and reading high

    Checks

    1. 1Read the Main pump P2 value on the cluster and compare it with a test gauge on the P2 pump outlet before blaming the sensor
    2. 2Unplug the P2 pump pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Compare the P2 reading with P1 while working a function
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 121-1Main pump P2 pressure sensor data below normal range

    The MCU reads the Main pump P2 pressure sensor below its normal range, so the pressure it expects on the P2 pump outlet is not showing up in the signal.· Lost message
    Check soon

    Causes

    • Low real pressure on the P2 pump outlet: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at the P2 pump pressure sensor
    • the P2 pump pressure sensor drifted or failed low

    Checks

    1. 1Compare the cluster Main pump P2 reading with a mechanical gauge on the P2 pump outlet; if the gauge is good the sensor or wiring is at fault
    2. 2Check the the P2 pump pressure sensor connector for water or green corrosion that adds resistance to the signal
    3. 3Compare the P2 reading with P1 while working a function
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 121-2Main pump P2 pressure sensor data error

    The MCU decides the Main pump P2 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Lost message
    Check soon

    Causes

    • Intermittent contact in the the P2 pump pressure sensor connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • the P2 pump pressure sensor failing intermittently

    Checks

    1. 1Watch the Main pump P2 reading while wiggling the harness at the P2 pump pressure sensor; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Compare the P2 reading with P1 while working a function
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 121-4Main pump P2 pressure sensor circuit voltage below normal

    The MCU sees the Main pump P2 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near the P2 pump pressure sensor
    • the P2 pump pressure sensor shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug the P2 pump pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the the P2 pump pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Compare the P2 reading with P1 while working a function
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 122-0Overload pressure sensor data above normal range

    The MCU reads the Overload pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Lost message
    Check soon

    Causes

    • Real overload circuit pressure high: line blocked or valve stuck
    • Open signal or ground wire at the the overload pressure sensor connector
    • the overload pressure sensor failed and reading high

    Checks

    1. 1Read the Overload value on the cluster and compare it with a test gauge on the overload warning circuit before blaming the sensor
    2. 2Unplug the overload pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Lift a load and see whether the overload pressure value rises with it
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 122-1Overload pressure sensor data below normal range

    The MCU reads the Overload pressure sensor below its normal range, so the pressure it expects on the overload warning circuit is not showing up in the signal.· Lost message
    Check soon

    Causes

    • Low real pressure on the overload warning circuit: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at the overload pressure sensor
    • the overload pressure sensor drifted or failed low

    Checks

    1. 1Compare the cluster Overload reading with a mechanical gauge on the overload warning circuit; if the gauge is good the sensor or wiring is at fault
    2. 2Check the the overload pressure sensor connector for water or green corrosion that adds resistance to the signal
    3. 3Lift a load and see whether the overload pressure value rises with it
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 122-2Overload pressure sensor data error

    The MCU decides the Overload pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Lost message
    Check soon

    Causes

    • Intermittent contact in the the overload pressure sensor connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • the overload pressure sensor failing intermittently

    Checks

    1. 1Watch the Overload reading while wiggling the harness at the overload pressure sensor; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Lift a load and see whether the overload pressure value rises with it
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 122-4Overload pressure sensor circuit voltage below normal

    The MCU sees the Overload pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near the overload pressure sensor
    • the overload pressure sensor shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug the overload pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the the overload pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Lift a load and see whether the overload pressure value rises with it
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 123-0Negative feedback 1 pressure sensor data above normal range

    The MCU reads the Negative feedback 1 pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Lost message
    Check soon

    Causes

    • Real negative control pressure high: restricted return or stuck valve
    • Open signal or ground wire at the negative feedback pressure sensor 1 connector
    • negative feedback pressure sensor 1 failed and reading high

    Checks

    1. 1Read the Negative feedback 1 value on the cluster and compare it with a test gauge on the negative feedback line of pump 1 before blaming the sensor
    2. 2Unplug negative feedback pressure sensor 1 and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Check the return line from the main valve for restriction
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 123-1Negative feedback 1 pressure sensor data below normal range

    The MCU reads the Negative feedback 1 pressure sensor below its normal range, so the pressure it expects on the negative feedback line of pump 1 is not showing up in the signal.· Lost message
    Check soon

    Causes

    • Low real pressure on the negative feedback line of pump 1: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at negative feedback pressure sensor 1
    • negative feedback pressure sensor 1 drifted or failed low

    Checks

    1. 1Compare the cluster Negative feedback 1 reading with a mechanical gauge on the negative feedback line of pump 1; if the gauge is good the sensor or wiring is at fault
    2. 2Check the negative feedback pressure sensor 1 connector for water or green corrosion that adds resistance to the signal
    3. 3Check the return line from the main valve for restriction
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 123-2Negative feedback 1 pressure sensor data error

    The MCU decides the Negative feedback 1 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Lost message
    Check soon

    Causes

    • Intermittent contact in the negative feedback pressure sensor 1 connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • negative feedback pressure sensor 1 failing intermittently

    Checks

    1. 1Watch the Negative feedback 1 reading while wiggling the harness at negative feedback pressure sensor 1; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Check the return line from the main valve for restriction
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 123-4Negative feedback 1 pressure sensor circuit voltage below normal

    The MCU sees the Negative feedback 1 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near negative feedback pressure sensor 1
    • negative feedback pressure sensor 1 shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug negative feedback pressure sensor 1 and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the negative feedback pressure sensor 1 connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Check the return line from the main valve for restriction
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 124-0Negative feedback 2 pressure sensor data above normal range

    The MCU reads the Negative feedback 2 pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Real condition
    Check soon

    Causes

    • Real negative control pressure high on pump 2: restricted return
    • Open signal or ground wire at the negative feedback pressure sensor 2 connector
    • negative feedback pressure sensor 2 failed and reading high

    Checks

    1. 1Read the Negative feedback 2 value on the cluster and compare it with a test gauge on the negative feedback line of pump 2 before blaming the sensor
    2. 2Unplug negative feedback pressure sensor 2 and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Compare feedback sensor 2 with sensor 1 with all levers neutral
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Hyundai 124-1Negative feedback 2 pressure sensor data below normal range

    The MCU reads the Negative feedback 2 pressure sensor below its normal range, so the pressure it expects on the negative feedback line of pump 2 is not showing up in the signal.· Real condition
    Check soon

    Causes

    • Low real pressure on the negative feedback line of pump 2: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at negative feedback pressure sensor 2
    • negative feedback pressure sensor 2 drifted or failed low

    Checks

    1. 1Compare the cluster Negative feedback 2 reading with a mechanical gauge on the negative feedback line of pump 2; if the gauge is good the sensor or wiring is at fault
    2. 2Check the negative feedback pressure sensor 2 connector for water or green corrosion that adds resistance to the signal
    3. 3Compare feedback sensor 2 with sensor 1 with all levers neutral
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Hyundai 124-2Negative feedback 2 pressure sensor data error

    The MCU decides the Negative feedback 2 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Erratic or implausible
    Check soon

    Causes

    • Intermittent contact in the negative feedback pressure sensor 2 connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • negative feedback pressure sensor 2 failing intermittently

    Checks

    1. 1Watch the Negative feedback 2 reading while wiggling the harness at negative feedback pressure sensor 2; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Compare feedback sensor 2 with sensor 1 with all levers neutral
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Hyundai 124-4Negative feedback 2 pressure sensor circuit voltage below normal

    The MCU sees the Negative feedback 2 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near negative feedback pressure sensor 2
    • negative feedback pressure sensor 2 shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug negative feedback pressure sensor 2 and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the negative feedback pressure sensor 2 connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Compare feedback sensor 2 with sensor 1 with all levers neutral
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Hyundai 125-0Pilot pump P3 pressure sensor data above normal range

    The MCU reads the Pilot pump P3 pressure sensor above its normal range, or the signal is floating open so the reading pegs high.· Lost message
    Check soon

    Causes

    • Real pilot pressure high: pilot relief stuck closed
    • Open signal or ground wire at the the P3 pilot pump pressure sensor connector
    • the P3 pilot pump pressure sensor failed and reading high

    Checks

    1. 1Read the Pilot pump P3 value on the cluster and compare it with a test gauge on the pilot supply line before blaming the sensor
    2. 2Unplug the P3 pilot pump pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
    3. 3Check pilot pressure with a gauge at the pilot test port with the engine at working speed
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 125-1Pilot pump P3 pressure sensor data below normal range

    The MCU reads the Pilot pump P3 pressure sensor below its normal range, so the pressure it expects on the pilot supply line is not showing up in the signal.· Lost message
    Check soon

    Causes

    • Low real pressure on the pilot supply line: weak pump, internal leak or a stuck-open relief
    • Partly shorted or high-resistance signal wire at the P3 pilot pump pressure sensor
    • the P3 pilot pump pressure sensor drifted or failed low

    Checks

    1. 1Compare the cluster Pilot pump P3 reading with a mechanical gauge on the pilot supply line; if the gauge is good the sensor or wiring is at fault
    2. 2Check the the P3 pilot pump pressure sensor connector for water or green corrosion that adds resistance to the signal
    3. 3Check pilot pressure with a gauge at the pilot test port with the engine at working speed
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 125-2Pilot pump P3 pressure sensor data error

    The MCU decides the Pilot pump P3 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system.· Lost message
    Check soon

    Causes

    • Intermittent contact in the the P3 pilot pump pressure sensor connector or harness
    • Electrical noise or a weak chassis ground on the sensor supply
    • the P3 pilot pump pressure sensor failing intermittently

    Checks

    1. 1Watch the Pilot pump P3 reading while wiggling the harness at the P3 pilot pump pressure sensor; a jump when you move it means a connection fault
    2. 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
    3. 3Check pilot pressure with a gauge at the pilot test port with the engine at working speed
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Hyundai 125-4Pilot pump P3 pressure sensor circuit voltage below normal

    The MCU sees the Pilot pump P3 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor.· Shorted low
    Check soon

    Causes

    • Signal wire rubbed through to ground near the P3 pilot pump pressure sensor
    • the P3 pilot pump pressure sensor shorted internally
    • Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference

    Checks

    1. 1Unplug the P3 pilot pump pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
    2. 2Measure the 5 V reference at the the P3 pilot pump pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
    3. 3Check pilot pressure with a gauge at the pilot test port with the engine at working speed
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Compare the cluster reading with a test gauge on the matching pressure port before replacing a sensor
  2. 2Check each sensor connector at the pump and valve bank for water and pushed-back pins
  3. 3Inspect the harness for chafing where it passes the pumps and valve bank
  4. 4Measure the sensor 5 V supply and ground at the plug with key on
  5. 5Compare with another sensor of the same type on the machine to confirm the fault is local

Causes

  • Sensor connector corroded or loose at the pump or valve bank
  • Hydraulic return restriction or relief fault on the pump circuit
  • Harness chafed near the pump or control valve
  • Failed sensor

Most codes here: lost message (15 of 24)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: The machine may feel slow or weak, pump control may be erratic, or an HCESPN number from 120 to 125 shows with an FMI of 0, 1, 2 or 4.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.