EF Logo

Genie · Operational indicator codes

Genie Fault Code CHrg

Charger interlock

What does Genie code CHrg mean?

The battery charger is connected to AC power, so machine functions are limited until it is unplugged. It is a status message; the LCD shows CHrg while the charger interlock is active. Urgency: information - a reminder or status message. Check first: unplug the charger from AC power and confirm the display returns to normal after a key cycle.

FaultInfoCHrgGenie · Operational indicator codes

Can I keep running with it?

Information

A reminder or status message. Nothing is failing yet.

What should I check first?

Unplug the charger from AC power and confirm the display returns to normal after a key cycle.

Then 3 more checks
Code shows hereFAULTCHrg

Where this code shows

Scissors: read the code on the platform LED display or the ground control LCD.

Checks

0 of 4 done

Causes

  • Charger plugged into an AC supply
  • Charger interlock input stuck active
  • Charger interlock wire shorted at the ground control box
  • Charger output wiring faulty

How it failed

You'll notice: The machine will not lift or drive while the charger is plugged in to AC power; unplugging it clears the code.

OtherRead from how the source describes the code

The source does not say how this one failed.

Meter test
Read the code with the service tool and note which other codes are active with it.
Good result
Codes that appear together usually share one cause - start with the wiring they share.

When to stop

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Operational indicator codes (LCD and LED)

Source

Genie GS-1530/1930/2032/2632 etc. Service and Repair Manual 1272217GT (Rev E1), Section 4 Diagnostics

This source lists CHrg and its meaning. The guidance on this page is general, not taken from it.

The source covers: Genie GS-1530/1532/1930/1932/2032/2632 slab scissors with SmartLink (GSDS) controls.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.