Genie · Control system fault codes (ALC-500 red/yellow LED)
Genie Fault Code 24‑17
Angle sensor not calibrated
What does Genie code 24-17 mean?
The boom angle sensor is not calibrated and boom speed is reduced. It usually follows a sensor or controller replacement. Urgency: check soon - the machine may derate or limit a function. Check first: run the boom angle sensor calibration from the service menu with the boom in the position the procedure calls for.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Run the boom angle sensor calibration from the service menu with the boom in the position the procedure calls for.
Then 3 more checksWhere this code shows
Scissors: read the code on the platform LED display or the ground control LCD.
Checks
0 of 4 done
Causes
- Angle sensor replaced without calibration
- Controller reset or software updated
- Calibration data lost
- Sensor mounting moved
How it failed
You'll notice: Boom speed is reduced because the boom angle sensor has no calibration.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: ALC-500 boom angle, load cell, limit switches and overload relays
- 24-11Angle sensor at 5.0 VOtherCheck soon
- 24-12Angle sensor value too highReal conditionCheck soon
- 24-15Angle sensor value too lowReal conditionCheck soon
- 24-16Angle sensor value at 0 VOtherCheck soon
- 24-17Angle sensor not calibratedOtherCheck soon
- 24-31Angle sensor invalid setupLost messageCheck soon
- 26-19Angle sensor cross check out of rangeOtherCheck soon
- 34-31Extend/retract limit switch invalid setupOtherCheck soon
- 34-36Extend/retract limit switch cross check faultReal conditionStop now
Show the other 16 codesHide the other codes
- 44-21Drive enable override switch faultOtherCheck soon
- 45-21Platform level switch faultOtherCheck soon
- 46-21Primary extend/retract switch faultOtherCheck soon
- 75-34Primary and secondary controller software mismatchPart or controllerStop now
- 76-12Platform load cell overloadedReal conditionStop now
- 76-13Platform load cell no responseLost messageStop now
- 76-15Platform load cell value too lowReal conditionStop now
- 76-17Platform load cell not calibratedReal conditionStop now
- 76-21Platform load cell internal status faultReal conditionStop now
- 76-31Platform load cell invalid setupReal conditionStop now
- 76-36Platform load cell cross check faultReal conditionStop now
- 79-13Hour meter no responseOtherInformation
- 82-21Overload recovery faultReal conditionCheck soon
- 102-12Overload cutout relay: 12 V present when offReal conditionStop now
- 102-15Overload function cutout relay: 0 V when onReal conditionStop now
- 103-12Overload engine cutout relay: input seen when offReal conditionStop now
Other Genie codes: Control system fault codes (ALC-500 red/yellow LED)
Related on Equipments Finder
Source
Genie S-60/S-65 Service and Repair Manual 1268492, Control System Fault Codes
This source lists 24-17 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Genie S-60, S-65, S-60 TRAX, S-65 TRAX, S-60 HC, S-60X/XC with ALC-500 controller.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.