EF Logo

Develon · Pressure sensors

Develon Boom, arm, bucket, travel and swing pressure sensors fault codes

One pilot pressure sensor per work function: boom, bucket, arm, left and right travel, swing and the attachment circuit. The controller uses them to tell what the operator is asking for and to time pump and valve outputs.

FaultCheckV000243Develon · Boom, arm, bucket, travel and swing pressure sensors
Code shows hereFAULTV000243

Where this code shows

Switch the key on and open the monitor fault or service menu on the gauge panel to see active codes.

What do these codes mean?

Develon codes V000243 to V000252 are all about the boom, arm, bucket, travel and swing pressure sensors. None needs an immediate stop. Start with this check: match the code title to the function and move that joystick axis while watching the monitor pressure.

How urgent are they?

None of the 10 codes here means stop now; all 10 can wait until the shift ends, but find the cause before the next one.

  • Check soon10

What should I check first?

Match the code title to the function and move that joystick axis while watching the monitor pressure.

Shared checks

10 of 10

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Develon V000243Boom up pressure sensor

    The boom up pilot pressure sensor reads the pilot pressure produced when the joystick raises the boom.· Lost message
    Check soon

    Causes

    • Failed pilot pressure sensor
    • Chafed harness along the boom
    • Water in the connector
    • No pilot pressure reaching the sensor port

    Checks

    1. 1Raise the boom slowly and watch the monitor pressure for a smooth rise from near the low end of 0.5-4.5 V.
    2. 2Check 5 V supply and ground at the connector with the key on.
    3. 3Inspect the harness where it flexes at the boom foot.
    4. 4Swap with another pilot sensor of the same type to see whether the code follows.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Develon V000244Bucket cr pressure sensor

    Same failure as V000243 on the bucket cr pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the bucket cr pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the bucket cr pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000244 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000245Boom down pressure sensor

    Same failure as V000243 on the boom down pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the boom down pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the boom down pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000245 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000246Bucket dump pressure sensor

    Same failure as V000243 on the bucket dump pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the bucket dump pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the bucket dump pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000246 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000247Arm in pressure sensor

    Same failure as V000243 on the arm in pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the arm in pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the arm in pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000247 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000248Arm out pressure sensor

    Same failure as V000243 on the arm out pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the arm out pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the arm out pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000248 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000249Travel left pressure sensor

    Same failure as V000243 on the travel left pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the travel left pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the travel left pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000249 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000250Travel right pressure sensor

    Same failure as V000243 on the travel right pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the travel right pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the travel right pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000250 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000251Swing pressure sensor

    Same failure as V000243 on the swing pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the swing pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the swing pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000251 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon V000252Attachment (option) pressure sensor

    Same failure as V000243 on the attachment (option) pressure sensor, a different part of the same kind as the boom up pressure sensor.· Other
    Check soon

    Causes

    • Fault in the attachment (option) pressure sensor or its wiring
    • Any cause listed under V000243

    Checks

    1. 1Check the attachment (option) pressure sensor connector and wiring first, then follow the checks listed under V000243.
    2. 2Clear the code and confirm whether V000252 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Match the code title to the function and move that joystick axis while watching the monitor pressure.
  2. 2Check the 5 V supply and ground at the sensor connector.
  3. 3Inspect the harness where it flexes along the boom and arm.
  4. 4Swap two sensors of the same type to see whether the code follows the part.
  5. 5Make sure the sensor port is not blocked and the pilot hose is not kinked.

Causes

  • Failed pilot pressure sensor
  • Chafed harness along the boom or arm
  • Water in the sensor connector
  • Loose pin or corroded terminal

When to stop

You'll notice: The matching movement may be slow, jerky or not recognised, and the monitor shows the code for that sensor.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.