EF Logo

Detroit · Fuel system

Detroit Low-pressure fuel supply, filter and water in fuel fault codes

The low-pressure fuel side includes the lift pump, the fuel filters, the water-in-fuel sensors, the supply fuel temperature sensor and the fuel level input. Detroit uses these codes for filter service warnings, water in the fuel and the sensors that watch this circuit.

FaultCheckSPN 94FMI 2Detroit · Low-pressure fuel supply, filter and water in fuel
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.

What do these codes mean?

Detroit codes SPN 94 FMI 2 to SPN 6301 FMI 15 are all about the low-pressure fuel supply, filter and water in fuel. The most common failure type is real condition (9 of 25); none needs an immediate stop. Start with this check: drain the water separator and check the fuel for water, wax or contamination.

How urgent are they?

None of the 25 codes here means stop now; all 25 can wait until the shift ends, but find the cause before the next one.

  • Check soon25

What should I check first?

Drain the water separator and check the fuel for water, wax or contamination.

Shared checks

25 of 25

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Detroit SPN 94 FMI 2Low Side Fuel Pressure Not Plausible

    Detroit lists SPN 94 FMI 2 as "Low Side Fuel Pressure Not Plausible".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting fuel supply sensor or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the fuel supply sensor reading with a second reference such as a gauge or another sensor on the engine.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 94 FMI 3Low Pressure Pump Output (LPPO) Circuit Failed High

    Detroit lists SPN 94 FMI 3 as "Low Pressure Pump Output (LPPO) Circuit Failed High".· Shorted high
    Check soon

    Causes

    • Signal wire shorted to the 5 V supply or open between the fuel supply sensor and the MCM
    • The fuel supply sensor has failed inside

    Checks

    1. 1Unplug the fuel supply sensor and measure the signal pin; a reading near supply with the sensor off means the harness is shorted or open.
    2. 2Bridge the signal to the return with the sensor unplugged; the reading should fall away if the harness is good.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 94 FMI 4Low Side Fuel Pressure Sensor Circuit Failed Low

    Detroit lists SPN 94 FMI 4 as "Low Side Fuel Pressure Sensor Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • Signal wire chafed against the engine and shorted to ground
    • The fuel supply sensor has failed inside or its supply wire is open

    Checks

    1. 1Unplug the fuel supply sensor and check whether the signal rises; if it stays low the harness is shorted to ground.
    2. 2Check the sensor supply at the connector with the key on and trace it back to the MCM if it is missing.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 94 FMI 11Low Side Fuel Pressure Not Plausible

    Same failure as SPN 94 FMI 2 ("Low Side Fuel Pressure Not Plausible") on a sibling part: Detroit lists SPN 94 FMI 11 as "Low Side Fuel Pressure Not Plausible".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 2, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 2, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 94 FMI 15Fuel Filter Service Warning

    Detroit lists SPN 94 FMI 15 as "Fuel Filter Service Warning".· Real condition
    Check soon

    Causes

    • A real fault in the system the fuel supply sensor measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the fuel supply sensor.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 94 FMI 16Fuel Filter Replacement Required

    Detroit lists SPN 94 FMI 16 as "Fuel Filter Replacement Required".· Real condition
    Check soon

    Causes

    • A real fault in the system the fuel supply sensor measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the fuel supply sensor.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 96 FMI 2Fuel Tank Level Sensor Stuck in Position

    Detroit lists SPN 96 FMI 2 as "Fuel Tank Level Sensor Stuck in Position".· Erratic or implausible
    Check soon

    Causes

    • Loose or corroded connector causing a noisy signal
    • A drifting fuel supply sensor or a related fault in the part it measures

    Checks

    1. 1Watch the live value while wiggling the harness to find an intermittent connection.
    2. 2Compare the fuel supply sensor reading with a second reference such as a gauge or another sensor on the engine.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 96 FMI 13Fuel Level Sensor Missing or Not Available

    Detroit lists SPN 96 FMI 13 as "Fuel Level Sensor Missing or Not Available".· Part or controller
    Check soon

    Causes

    • Sensor aged, contaminated or out of calibration
    • A real fault in the system being measured

    Checks

    1. 1Compare the fuel supply sensor reading with a reference gauge or thermometer with the engine off and cold.
    2. 2Check the system around the fuel supply sensor for leaks, restrictions or contamination.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 96 FMI 19Fuel Level Sensor Signal Error

    Detroit lists SPN 96 FMI 19 as "Fuel Level Sensor Signal Error".· Lost message
    Check soon

    Causes

    • Signal path broken at the connector or the harness
    • Failed sensor or module

    Checks

    1. 1Check the connector and the power supply to the fuel supply sensor.
    2. 2Check the signal wire to the MCM for an open.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 97 FMI 3Water-in-Fuel Circuit Failed High

    Same failure as SPN 94 FMI 3 ("Low Pressure Pump Output (LPPO) Circuit Failed High") on a sibling part: Detroit lists SPN 97 FMI 3 as "Water-in-Fuel Circuit Failed High".· Shorted high
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 97 FMI 4Water-in-Fuel Circuit Failed Low

    Same failure as SPN 94 FMI 4 ("Low Side Fuel Pressure Sensor Circuit Failed Low") on a sibling part: Detroit lists SPN 97 FMI 4 as "Water-in-Fuel Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 4, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 4, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 97 FMI 15Water-in-Fuel Warning

    Detroit lists SPN 97 FMI 15 as "Water-in-Fuel Warning".· Real condition
    Check soon

    Causes

    • A real fault in the system the fuel supply sensor measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the fuel supply sensor.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 97 FMI 16Water-in-Fuel Warning

    Same failure as SPN 97 FMI 15 ("Water-in-Fuel Warning") on a sibling part: Detroit lists SPN 97 FMI 16 as "Water-in-Fuel Warning".· Real condition
    Check soon

    Causes

    • The causes listed under SPN 97 FMI 15, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 97 FMI 15, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 97 FMI 31Water-in-Fuel Warning - Ignored

    Detroit lists SPN 97 FMI 31 as "Water-in-Fuel Warning - Ignored".· Real condition
    Check soon

    Causes

    • A real fault in the system the fuel supply sensor watches
    • Sensor or wiring fault

    Checks

    1. 1Read the live value and compare it with a reference.
    2. 2Check the connector and wiring.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 174 FMI 0Supply Fuel Temperature Sensor Too High

    Detroit lists SPN 174 FMI 0 as "Supply Fuel Temperature Sensor Too High".· Real condition
    Check soon

    Causes

    • A real fault in the system the fuel supply sensor measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the fuel supply sensor.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 174 FMI 3Supply Fuel Temperature Sensor Open Circuit

    Detroit lists SPN 174 FMI 3 as "Supply Fuel Temperature Sensor Open Circuit".· Shorted high
    Check soon

    Causes

    • Signal wire shorted to the 5 V supply or open between the fuel supply sensor and the MCM
    • The fuel supply sensor has failed inside

    Checks

    1. 1Unplug the fuel supply sensor and measure the signal pin; a reading near supply with the sensor off means the harness is shorted or open.
    2. 2Bridge the signal to the return with the sensor unplugged; the reading should fall away if the harness is good.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 174 FMI 4Supply Fuel Temperature Sensor Short Circuit to Ground

    Same failure as SPN 94 FMI 4 ("Low Side Fuel Pressure Sensor Circuit Failed Low") on a sibling part: Detroit lists SPN 174 FMI 4 as "Supply Fuel Temperature Sensor Short Circuit to Ground".· Shorted low
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 4, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 4, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 174 FMI 11Fuel Temperature Sensor, General Temperature Plausibility Error

    Same failure as SPN 94 FMI 2 ("Low Side Fuel Pressure Not Plausible") on a sibling part: Detroit lists SPN 174 FMI 11 as "Fuel Temperature Sensor, General Temperature Plausibility Error".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 2, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 2, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 174 FMI 14Fuel Temperature Sensor Signal Not Plausible

    Same failure as SPN 94 FMI 2 ("Low Side Fuel Pressure Not Plausible") on a sibling part: Detroit lists SPN 174 FMI 14 as "Fuel Temperature Sensor Signal Not Plausible".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 2, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 2, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 174 FMI 17Fuel Temperature Sensor, Rise Too Slow

    Detroit lists SPN 174 FMI 17 as "Fuel Temperature Sensor, Rise Too Slow".· Real condition
    Check soon

    Causes

    • A real fault in the system the fuel supply sensor measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the fuel supply sensor.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 5395 FMI 15Idle Fuel Quantity Out of Range

    Detroit lists SPN 5395 FMI 15 as "Idle Fuel Quantity Out of Range".· Real condition
    Check soon

    Causes

    • A real fault in the system the fuel supply sensor measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the fuel supply sensor.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 5540 FMI 2Fuel Temperature Signal Not Plausible

    Same failure as SPN 94 FMI 2 ("Low Side Fuel Pressure Not Plausible") on a sibling part: Detroit lists SPN 5540 FMI 2 as "Fuel Temperature Signal Not Plausible".· Erratic or implausible
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 2, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 2, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Watch the live value on the service tool while you flex the harness and tap the connector.

    Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.

  • Detroit SPN 6301 FMI 3Signal Range High Active for WIF Sensor 2

    Same failure as SPN 94 FMI 3 ("Low Pressure Pump Output (LPPO) Circuit Failed High") on a sibling part: Detroit lists SPN 6301 FMI 3 as "Signal Range High Active for WIF Sensor 2".· Shorted high
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 6301 FMI 4Signal Range High Active for WIF Sensor 2

    Same failure as SPN 94 FMI 3 ("Low Pressure Pump Output (LPPO) Circuit Failed High") on a sibling part: Detroit lists SPN 6301 FMI 4 as "Signal Range High Active for WIF Sensor 2".· Shorted low
    Check soon

    Causes

    • The causes listed under SPN 94 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 94 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 6301 FMI 15Water In Fuel for WIF2

    Detroit lists SPN 6301 FMI 15 as "Water In Fuel for WIF2".· Real condition
    Check soon

    Causes

    • A real fault in the system the fuel supply sensor measures
    • Sensor reading skewed by a wiring or connector problem

    Checks

    1. 1Confirm the real value with a mechanical gauge or an independent reading before replacing the fuel supply sensor.
    2. 2Check the system for the condition the code describes and fix it first.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Drain the water separator and check the fuel for water, wax or contamination.
  2. 2Inspect or replace the fuel filters if the service interval is overdue and measure the supply pressure.
  3. 3Check the fuel temperature, pressure and water-in-fuel sensor connectors for corrosion and bent pins.
  4. 4Test the signal wires for continuity and for shorts to ground or to the sensor supply.
  5. 5Check the tank pickup and the suction lines for air leaks and kinks.

Causes

  • Plugged primary or secondary fuel filter
  • Water in the fuel or a water separator that has not been drained
  • Low-pressure pump output weak or its wiring faulty
  • Sensor connector or wiring damage

Most common here: real condition (9 of 25)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: A fuel filter or water-in-fuel lamp, a power loss or hard starting; water in fuel can lead to a derate.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.