Skyjack · On-board battery charger codes
Skyjack Fault Code F‑0‑0‑1
Charger fault: DC-DC (LLC) excessive leakage
What does Skyjack code F-0-0-1 mean?
The charger's DC-DC stage reported excessive leakage in its LLC section and shut itself down. Skyjack lists this as an internal charger fault, so the fix is a power reset first and the charger itself if it returns. Urgency: stop now - shut down and fix before working on. Check first: unplug the AC supply and disconnect the battery from the charger.
Can I keep running with it?
Stop now
Shut down and fix before working on. Running on risks damage or the machine locks out.
What should I check first?
Unplug the AC supply and disconnect the battery from the charger
Then 4 more checksWhere this code shows
Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).
Checks
0 of 5 done
Causes
- Failed component in the charger's DC-DC (LLC) power stage
- A one-off fault that clears with a power reset
- Damp or contaminated charger board
How it failed
You'll notice: The charger shows a solid red fault light with F-0-0-1 on its display and stops charging, so the batteries do not recharge.
OtherRead from how the source describes the code
The source does not say how this one failed.
- Meter test
- Read the code with the service tool and note which other codes are active with it.
- Good result
- Codes that appear together usually share one cause - start with the wiring they share.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: On-board battery charger codes
- E-0-0-1Charger error: battery voltage over limitPart or controllerCheck soon
- F-0-0-1Charger fault: DC-DC (LLC) excessive leakageOtherStop now
- E-0-0-2Charger error: battery voltage too low to startShorted lowCheck soon
- F-0-0-2Charger fault: PFC excessive leakageOtherStop now
- E-0-0-3Charger error: charge time limit reachedOtherCheck soon
- F-0-0-3Charger fault: PFC took too long to boostLost messageStop now
- E-0-0-4Charger error: batteries could not be trickle chargedLost messageCheck soon
- F-0-0-4Charger fault: current offset calibration failedPart or controllerStop now
- F-0-0-5Charger fault: DC relay voltage drop too highReal conditionStop now
Show the other 7 codesHide the other codes
- F-0-0-6Charger fault: DC-DC and battery sense currents differOtherStop now
- E-0-0-7Charger error: amp-hour limit reachedOtherCheck soon
- 3 LEDs, 1 blinkCharger LEDs: 3 blinks, output connection errorOtherCheck soon
- 3 LEDs, 2 blinkCharger LEDs: 2 blinks, AC voltage out of rangeShorted lowCheck soon
- 3 LEDs, 3 blinkCharger LEDs: 3 blinks, charger overheatedReal conditionCheck soon
- 3 LEDs, 4 blinkCharger LEDs: 4 blinks, over-currentOtherCheck soon
- 100% LED blinkingCharger LEDs: 100% LED blinking, 18 hour timerOtherCheck soon
Source
This source lists F-0-0-1 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Skyjack SJIII 3220, 3226, 4620, 4626 and 4632 DC electric scissors with the on-board IC series charger (manual 157928AM, serials 3220 60 002 259 up, 3226 27 006 432 up, 46xx 70 007 139 up).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.