This page covers the on-board battery charger: its internal F-0-0-x faults, the E-0-0-x charge errors and what the LED blink patterns mean. The on-board charger shows F-0-0-x for faults found inside its own power stages: the DC-DC (LLC) converter, the PFC input stage, the DC relay and the current sensing.

More about these parts

The charger shows E-0-0-x when the charge cycle itself cannot start or finish: battery voltage out of range, a time or amp-hour limit reached, or a trickle charge that fails. On the operating-manual charger the three charge-state LEDs blink in patterns to report a connection, AC supply, temperature or current problem, and a blinking 100 percent LED reports the 18 hour timer.

FaultStopF-0-0-1Skyjack · On-board battery charger codes
Code shows hereFAULTF-0-0-1

Where this code shows

Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).

What do these codes mean?

Skyjack codes E-0-0-1 to 100% LED blinking are all about the on-board battery charger codes. The most common failure type is shorted low (2 of 16); 6 need an immediate stop. Start with this check: disconnect AC and the battery from the charger for at least 30 seconds, then reconnect.

How urgent are they?

6 of 16 codes here mean stop now; the other 10 can wait until the shift ends, but find the cause before the next one.

  • Stop now6
  • Check soon10

What should I check first?

Disconnect AC and the battery from the charger for at least 30 seconds, then reconnect

Shared checks

16 of 16

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Skyjack E-0-0-1Charger error: battery voltage over limit

    The charger saw battery voltage above its software limit at the start of a charge cycle, typically 2.5 V per cell on lead-acid batteries.· Part or controller
    Check soon

    Causes

    • Batteries already fully charged or just charged
    • Charger voltage model does not match the battery pack
    • Poor battery connection giving a false high reading

    Checks

    1. 1Check the battery voltage and cable connections at the charger output
    2. 2Confirm the charger voltage rating suits the battery pack
    3. 3Let the batteries rest after a recent charge and try again
    4. 4Check that no battery of the wrong voltage has been fitted
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F-0-0-1Charger fault: DC-DC (LLC) excessive leakage

    The charger's DC-DC stage reported excessive leakage in its LLC section and shut itself down.· Other
    Stop now

    Causes

    • Failed component in the charger's DC-DC (LLC) power stage
    • A one-off fault that clears with a power reset
    • Damp or contaminated charger board

    Checks

    1. 1Unplug the AC supply and disconnect the battery from the charger
    2. 2Leave both disconnected for at least 30 seconds, as the manual says
    3. 3Reconnect and start a charge to see if F-0-0-1 returns
    4. 4Look inside the charger area for water, dirt or heat damage
    5. 5If it returns, contact Skyjack service for a replacement charger
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack E-0-0-2Charger error: battery voltage too low to start

    The battery voltage is below the level needed to start a charge, typically 0.1 V per cell.· Shorted low
    Check soon

    Causes

    • Batteries deeply discharged
    • Battery cable disconnected or loose
    • Charger voltage does not match the batteries
    • Dead cell in the pack

    Checks

    1. 1Check the battery voltage and cable connections at the charger output
    2. 2Check the charger is the correct voltage for the battery pack
    3. 3Check battery size and condition; use another charger to lift an over-discharged pack above the minimum
    4. 4Wait for the error to clear after the fix, as it resets itself
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Skyjack F-0-0-2Charger fault: PFC excessive leakage

    The charger's power factor correction (PFC) stage detected excessive leakage and tripped.· Other
    Stop now

    Causes

    • Failed component in the PFC stage on the AC input side
    • One-off fault caused by a supply surge
    • Moisture inside the charger

    Checks

    1. 1Disconnect AC and the battery from the charger for at least 30 seconds
    2. 2Check the AC supply and plug for burn marks or a damaged cord
    3. 3Reconnect and start a charge to see if the fault returns
    4. 4Check the AC source voltage is steady with a meter
    5. 5Contact Skyjack service if the code comes back
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack E-0-0-3Charger error: charge time limit reached

    The charger ran for its maximum time without the batteries finishing.· Other
    Check soon

    Causes

    • Output reduced by heat or low AC voltage
    • Shorted or damaged cell, or a tired battery
    • Batteries too large for the charger
    • Loose or corroded connection or a parasitic load on the batteries

    Checks

    1. 1Check the ambient temperature and AC voltage during charging
    2. 2Check for shorted or damaged cells and the battery health
    3. 3Check the batteries are not too large for the charger
    4. 4Check the battery connections for looseness or corrosion
    5. 5Turn off any other device running from the batteries
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack F-0-0-3Charger fault: PFC took too long to boost

    The PFC stage did not reach its boost voltage in the time allowed.· Lost message
    Stop now

    Causes

    • Weak or unstable AC supply
    • Long extension lead dropping the voltage
    • Failed PFC stage inside the charger

    Checks

    1. 1Measure the AC voltage at the socket the charger is plugged into
    2. 2Remove any long or thin extension lead and plug in directly
    3. 3Disconnect AC and the battery for 30 seconds, then retry the charge
    4. 4Try a different outlet on another circuit to rule out the supply
    5. 5Contact Skyjack service if the fault persists on a good supply
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Skyjack E-0-0-4Charger error: batteries could not be trickle charged

    The battery could not be brought up to the minimum voltage by trickle charge.· Lost message
    Check soon

    Causes

    • Shorted or damaged cell
    • Battery worn out
    • Poor DC connections
    • High charger temperature cutting the output

    Checks

    1. 1Check for shorted or damaged cells in the pack with a hydrometer or load test
    2. 2Replace the battery if its health is poor after testing it
    3. 3Check the DC connections for looseness or corrosion
    4. 4Check the charger is not overheating, which cuts its output
    5. 5Note that some new batteries trigger it as their voltage dips when charging starts
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Skyjack F-0-0-4Charger fault: current offset calibration failed

    The charger could not calibrate its current offset at start-up.· Part or controller
    Stop now

    Causes

    • Failed current sensing inside the charger
    • Charger started with the battery connected in an unusual state
    • Internal board fault

    Checks

    1. 1Disconnect AC and the battery for at least 30 seconds
    2. 2Reconnect the battery first, then AC, and start a charge
    3. 3Check the battery cable connections are clean and tight
    4. 4Contact Skyjack service if it repeats after the reset
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Skyjack F-0-0-5Charger fault: DC relay voltage drop too high

    The charger measured too much voltage drop across its DC output relay while the relay was closed.· Real condition
    Stop now

    Causes

    • Worn or burnt DC relay contacts inside the charger
    • Poor connection on the charger's DC output
    • Internal board fault

    Checks

    1. 1Disconnect AC and the battery for at least 30 seconds, then retry the charge
    2. 2Check the DC output cables and battery terminals are clean and tight
    3. 3Look for heat discolouration on the charger output lead and plug
    4. 4Contact Skyjack service if the code repeats after the reset
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Skyjack F-0-0-6Charger fault: DC-DC and battery sense currents differ

    The charger saw a large difference between the current measured inside its DC-DC stage and the current measured at the battery sense.· Other
    Stop now

    Causes

    • Loose or corroded battery connection upsetting the sense reading
    • Failed current sensing inside the charger
    • Damaged sense wire

    Checks

    1. 1Disconnect AC and the battery for at least 30 seconds, then retry
    2. 2Clean and tighten both battery cable terminals at the batteries
    3. 3Inspect the charger output lead for damage or a loose crimp
    4. 4Contact Skyjack service if it repeats after the reset
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack E-0-0-7Charger error: amp-hour limit reached

    The charger reached its limit for amp-hours delivered.· Other
    Check soon

    Causes

    • Output cut back by heat or low AC volts, so the amp-hours ran out first
    • Shorted or damaged cells soaking up the charge
    • Deeply discharged battery needing more than the allowed amp-hours
    • Loose or corroded connection or an extra load drawing from the pack

    Checks

    1. 1Check ambient temperature and AC voltage while it charges
    2. 2Check for shorted or damaged cells in the pack
    3. 3Retry charging a deeply discharged battery after a rest
    4. 4Check connections for looseness or corrosion at both ends
    5. 5Turn off any other devices running from the batteries
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Skyjack 100% LED blinkingCharger LEDs: 100% LED blinking, 18 hour timer

    Only the 100% LED blinks.· Other
    Check soon

    Causes

    • Worn or damaged battery
    • Shorted cell
    • Loose battery connection
    • Battery too large for the charger

    Checks

    1. 1Check the battery condition and test each cell
    2. 2Check the connections for looseness or corrosion
    3. 3Load test the batteries to see if they hold charge
    4. 4Replace the battery if it will not hold charge
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Disconnect AC and the battery from the charger for at least 30 seconds, then reconnect
  2. 2Measure the battery voltage and each battery in the string
  3. 3Check the battery and AC connections at both ends of each lead
  4. 4Check the AC supply and plug for burn marks or damage
  5. 5Check battery cables and terminals for corrosion and looseness
  6. 6Measure the AC supply voltage at the plug end
  7. 7Check the DC cable and battery connections for looseness

Causes

  • Failed component inside the charger
  • Battery voltage too low or too high
  • Battery or AC connection loose
  • Supply surge or poor AC supply

Most common here: shorted low (2 of 16)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: The charger stops and shows an F-0-0-x fault.

Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.