Chassis tilt sensor not calibrated

What does JLG code 813 mean?

The chassis tilt sensor has not been calibrated, so the controller cannot use its tilt readings reliably. Tilt based limits may behave incorrectly until it is calibrated. Urgency: check soon - the machine may derate or limit a function. Check first: park the machine on firm level ground and confirm the chassis is level with a spirit level.

FaultCheck813JLG · Sensors

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Park the machine on firm level ground and confirm the chassis is level with a spirit level

Then 4 more checks
Code shows hereFAULT813

Where this code shows

Turn the key on and watch the fault lamp or platform display.

Checks

0 of 5 done

Causes

  • Tilt sensor recently replaced and not calibrated
  • Calibration data lost after a module or software change
  • Calibration never done at commissioning
  • Sensor shifted on its mount after an impact

How it failed

You'll notice: The tilt cutout may behave wrongly because the chassis tilt sensor has no calibration stored.

OtherRead from how the source describes the code

The source does not say how this one failed.

Meter test
Read the code with the service tool and note which other codes are active with it.
Good result
Codes that appear together usually share one cause - start with the wiring they share.

When to stop

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: Load sensing, chassis tilt and transport sensors

Source

JLG 600S/660SJ Service and Maintenance Manual 3121298, section 6 (Table 6-8 Fault Code List)

This source lists 813 and its meaning. The guidance on this page is general, not taken from it.

The source covers: JLG 600S, 600SJ, 660SJ with newer module software; same DTC scheme on other JLG Control System booms, confirm in your manual.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.