EF Logo

JCB · Machine controller (MECU / DECU)

JCB Machine sensor, thumbwheel, steering and door inputs fault codes

The machine controller reads the flow thumbwheel, the power band selector, the swing rotation sensor and other sensors from the 5 V reference (Vref). These codes report high or low voltages or a shorted reference.

FaultCheckB105AJCB · Machine sensor, thumbwheel, steering and door inputs
Code shows hereFAULTB105A

Where this code shows

Switch the key on and note any warning lamp or fault icon on the cluster.

What do these codes mean?

JCB codes B105A to C1355 are all about the machine sensor, thumbwheel, steering and door inputs. The most common failure type is shorted high (8 of 17); none needs an immediate stop. Start with this check: measure the supply voltage at the machine sensor input plug with the key on.

How urgent are they?

None of the 17 codes here means stop now; 16 can wait until the shift ends, but find the cause before the next one; 1 is information only.

  • Check soon16
  • Info1

What should I check first?

Measure the supply voltage at the machine sensor input plug with the key on

Shared checks

17 of 17

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JCB B105AHigh voltage detected at sensor

    A sensor on the machine controller reads a high voltage.· Shorted high
    Check soon

    Causes

    • Sensor open circuit or shorted to supply
    • 5 V reference problem

    Checks

    1. 1Read all sensor inputs on live data and find the one at the top of its range
    2. 2Check that sensor's plug and the 5 V reference
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB B105BSensor voltage high (throttle control)

    The throttle control sensor voltage is high.· Shorted high
    Check soon

    Causes

    • Throttle control potentiometer open
    • Throttle signal shorted to the 5 V reference

    Checks

    1. 1Move the throttle control and watch the voltage across its range
    2. 2Check the throttle control plug and wiring
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB B105CHigh voltage detected at sensor (hydraulic controller)

    A sensor on the hydraulic controller reads a high voltage.· Shorted high
    Check soon

    Causes

    • Hydraulic controller sensor open or shorted to supply
    • Shared 5 V reference fault

    Checks

    1. 1Read the hydraulic controller inputs on live data and find the high one
    2. 2Check that sensor's plug and wiring
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB B105DLow voltage detected in sensor circuit

    A sensor circuit shows a low voltage.· Shorted low
    Check soon

    Causes

    • Sensor signal shorted to ground
    • Sensor supply missing

    Checks

    1. 1Read the sensor inputs and find the one near zero
    2. 2Check the supply and the signal wire at that sensor
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C134FRevolver no longer aligned in travel mode

    The controller reports that the revolver (the swivel joint between the upper and lower structure) is no longer in the aligned position while the machine is in travel mode.· Lost message
    Check soon

    Causes

    • Upper structure not in the travel alignment position
    • Alignment sensor or switch misadjusted or failed
    • Wiring or connector fault at the sensor
    • Swing lock or drive not engaging correctly

    Checks

    1. 1Turn the upper structure back to the travel position and see whether the warning clears
    2. 2Check the alignment sensor position and that it changes state on live data
    3. 3Inspect the sensor connector and wiring for corrosion and chafing
    4. 4Check that the swing lock engages and releases correctly in travel mode
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB P0173Steering angle sensor over range

    The steering angle sensor reports a value beyond its allowed range, so the controller cannot tell the true wheel angle.· Lost message
    Check soon

    Causes

    • Steering angle sensor out of calibration
    • Sensor mounting loose or linkage damaged
    • Wiring or connector fault at the sensor
    • Sensor failed giving an out-of-range signal

    Checks

    1. 1Check the sensor mounting and linkage for play or damage
    2. 2Run the steering angle calibration on the diagnostic tool
    3. 3Watch the angle on live data while steering lock to lock
    4. 4Check the sensor connector and wiring for corrosion and chafing
    5. 5Measure the sensor supply and signal at the plug against the ECU pin out
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JCB B0300Low flow thumbwheel voltage high

    The low flow thumbwheel signal voltage is too high.· Shorted high
    Check soon

    Causes

    • Low flow thumbwheel potentiometer open
    • Signal wire shorted to the 5 V reference

    Checks

    1. 1Turn the low flow thumbwheel and watch the voltage
    2. 2Check the signal wire for a short to 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB B0301High flow thumbwheel voltage low

    The thumbwheel signal named in the title reads low.· Shorted low
    Check soon

    Causes

    • Thumbwheel signal wire shorted to ground
    • Thumbwheel potentiometer failed

    Checks

    1. 1Turn the thumbwheel and watch the voltage
    2. 2Check the signal wire for a short to ground
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB B0302High flow thumbwheel voltage high

    The high flow thumbwheel signal voltage is too high.· Shorted high
    Check soon

    Causes

    • High flow thumbwheel potentiometer open
    • Signal wire shorted to the 5 V reference

    Checks

    1. 1Turn the high flow thumbwheel and watch the voltage
    2. 2Check the signal wire for a short to 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB B0303High flow thumbwheel voltage low

    The high flow thumbwheel signal voltage is too low, a short to ground or a lost signal on the high flow setting.· Shorted low
    Check soon

    Causes

    • High flow thumbwheel signal wire shorted to ground
    • High flow thumbwheel potentiometer failed

    Checks

    1. 1Turn the high flow thumbwheel and watch the voltage
    2. 2Check the signal wire for a short to ground
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB B1300Voltage above normal in power band select circuit

    The power band select circuit voltage is above normal.· Shorted high
    Check soon

    Causes

    • Power band selector potentiometer open
    • Signal wire shorted to the 5 V feed

    Checks

    1. 1Turn the power band selector and watch the voltage
    2. 2Check the signal wire for a short to 5 V
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB B1301Power band select potentiometer voltage low

    The power band select potentiometer voltage is low, a short to ground or a lost signal, so the machine may stay in the lowest band.· Shorted low
    Check soon

    Causes

    • Power band selector signal shorted to ground
    • Selector potentiometer failed

    Checks

    1. 1Turn the selector and watch the voltage
    2. 2Check the signal wire for a short to ground
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C1323Vref shorted to battery

    The 5 V sensor reference (Vref) is shorted to battery voltage.· Shorted high
    Check soon

    Causes

    • Vref wire touching a battery-voltage wire
    • A sensor on the reference failed and tied it to supply

    Checks

    1. 1Unplug the sensors on the Vref one at a time and watch the voltage
    2. 2Inspect the Vref harness for chafing against a live wire
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB C1324Vref shorted to ground

    The 5 V sensor reference (Vref) is shorted to ground, so all sensors on it lose their supply and read near zero.· Shorted low
    Check soon

    Causes

    • Vref wire shorted to ground
    • A sensor on the reference shorted internally

    Checks

    1. 1Unplug the sensors on the Vref one at a time and watch whether the voltage returns
    2. 2Check the Vref harness for a short to chassis
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C1327Swing rotation sensor shorted to battery

    The swing rotation sensor is shorted to battery voltage, so the controller cannot read the upper structure rotation and swing functions may be limited.· Shorted high
    Check soon

    Causes

    • Swing rotation sensor signal wire touching a live wire
    • Sensor failed with its output at supply

    Checks

    1. 1Check the swing rotation sensor plug and wiring for contact with a live wire
    2. 2Check the sensor output with the engine off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • JCB C1328Swing rotation sensor shorted to ground

    The swing rotation sensor is shorted to ground, so the controller loses the swing position signal and swing functions may be limited.· Shorted low
    Check soon

    Causes

    • Swing rotation sensor signal wire shorted to ground
    • Sensor failed with its output at zero

    Checks

    1. 1Check the swing rotation sensor wiring for a short to ground
    2. 2Check the sensor supply and output at the plug
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • JCB C1355Door open while cab raised

    The machine controller sees the cab door open while the cab is raised on a machine where the cab can be lifted, so it blocks the movement as a safety measure.· Lost message
    Info

    Causes

    • Cab door really open when the cab is raised
    • Door switch misadjusted or stuck
    • Cab raise sensor or switch fault
    • Wiring or connector fault at the door switch

    Checks

    1. 1Close the door fully and see whether the warning clears
    2. 2Check the door switch position and that it changes state on live data
    3. 3Check the cab raise switch or sensor and its wiring
    4. 4Inspect the switch connectors for corrosion and pushed-back pins
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

Shared checks

Checks, in order

  1. 1Measure the supply voltage at the machine sensor input plug with the key on
  2. 2Check the wiring to the machine sensor input for opens, shorts to ground or battery, and chafing
  3. 3Measure the machine sensor input signal at the plug while moving the control through its range
  4. 4Unplug the sensors on the circuit one at a time and see whether the code clears

Causes

  • Sensor or potentiometer failed
  • Wiring fault
  • Vref short
  • Supply fault

Most common here: shorted high (8 of 17)

Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

When to stop

You'll notice: A function may be limited or follow the wrong setting.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.