JCB · Engine ECU (Dieselmax / Ecomax) - fuel system
JCB Lift pump, fuel contamination and fuel level sensors fault codes
The lift pump pulls diesel from the tank and feeds the high-pressure pump. The ECU switches it through a relay, so these codes cover the pump circuit and the relay output.
More about these partsLess
The fuel filter clogging sensor watches the pressure drop across the filter, and the water-in-fuel sensor in the filter bowl detects collected water. Both warn the operator before dirty or wet fuel damages the injection equipment. The fuel level sender in the tank is a float and variable resistor read by the machine controller. It drives the fuel gauge and the low and empty fuel alarms.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes C101D to P2269 are all about the lift pump, fuel contamination and fuel level sensors. The most common failure type is open circuit (3 of 17); none needs an immediate stop. Start with this check: listen for the lift pump priming for a few seconds when the key goes on.
How urgent are they?
None of the 17 codes here means stop now; 16 can wait until the shift ends, but find the cause before the next one; 1 is information only.
- Check soon16
- Info1
What should I check first?
Listen for the lift pump priming for a few seconds when the key goes on
Shared checks17 of 17
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB C101DFuel level low alarm
The fuel level has fallen to the low alarm point. The operator sees a low fuel warning, and the machine should be refuelled soon to avoid running dry and drawing air into the fuel system.· OtherOtherInfoCauses
- Fuel actually running low
- Fuel level sender float stuck or reading low
- Wire to the fuel sender damaged
Checks
- 1Look at the fuel in the tank and refuel if low
- 2Compare the gauge reading with the real fuel level
- 3Check the sender wiring and plug for corrosion
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB C101EFuel level empty alarm
The fuel level has fallen to empty. The operator sees an empty fuel warning, and running dry can draw air into the fuel system, causing a hard start and the need to bleed the system.· Lost messageLost messageCheck soonCauses
- Fuel tank actually empty
- Fuel level sender reading empty in error
- Open circuit in the sender wire
Checks
- 1Refuel the machine, then check the gauge rises
- 2If the engine ran dry, bleed the fuel system before restarting
- 3Check the sender connector for corrosion and bent pins
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB C101FFuel level sensor short circuit
Fuel level sensor short circuit. The controller found the fuel level sensor output or circuit shorted and drawing too much current, so it protects the driver.· Short circuitShort circuitCheck soonCauses
- Fuel level sensor coil shorted internally, drawing too much current
- Harness chafed through and touching the frame or a supply wire near the fuel level sensor
- Water in the fuel level sensor connector
Checks
- 1Unplug the fuel level sensor and measure its resistance, looking for a very low reading
- 2Check each wire for a short to ground and to battery with the plug removed
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB P0627Lift pump circuit open
The ECU found the fuel lift pump drive circuit open, so the pump is not being powered. The engine may crank but not start, or it will lose power and stall as the high-pressure pump runs out of fuel.· Open circuitOpen circuitCheck soonCauses
- Open circuit in the lift pump feed or its relay drive
- Failed lift pump motor, drawing no current
- Blown lift pump fuse or a corroded relay socket
Checks
- 1Listen for the lift pump priming for a few seconds when the key is turned on
- 2Check the lift pump fuse and relay, and swap the relay with a known good one
- 3Measure voltage at the lift pump connector with the key on
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB P0628Lift pump circuit short to ground
Lift pump circuit short to ground. The lift pump circuit short to ground circuit is pulled down to ground, so the controller sees the signal or output stuck low.· Shorted lowShorted lowCheck soonCauses
- Wire for the lift pump circuit short to ground chafed and touching chassis or engine ground
- Lift pump circuit short to ground coil or sensor shorted internally
Checks
- 1Unplug the lift pump circuit short to ground and check each wire for a short to chassis ground
- 2Measure the resistance of the lift pump circuit short to ground and compare it with the manual value
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JCB P0629Lift pump circuit short to battery
Lift pump circuit short to battery. The lift pump circuit short to battery circuit is being pulled up to battery or supply voltage, so the controller cannot read or drive it correctly.· Shorted highShorted highCheck soonCauses
- Wire for the lift pump circuit short to battery touching a battery-fed wire in the harness
- Water or damage inside the lift pump circuit short to battery connector bridging to supply
Checks
- 1Unplug the lift pump circuit short to battery and check the signal wire for voltage with the key on, any battery voltage means a short to supply
- 2Inspect the harness for chafing where it crosses live wires near the lift pump circuit short to battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
JCB P0656Fuel level sensor output circuit fault
Fuel level sensor output circuit fault. The controller logged a fault on the fuel level sensor output circuit, which affects how the fuel level sensor works until the cause is found.· OtherOtherCheck soonCauses
- Fuel level sensor output circuit or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the fuel level sensor output circuit and look for a value that is stuck or implausible
- 2Check the fuel level sensor output circuit connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB C1020Fuel level sensor open circuit
Fuel level sensor open circuit. The controller finds no current path in the fuel level sensor circuit, so the fuel level sensor cannot be driven or read as expected.· Open circuitOpen circuitCheck soonCauses
- Open wire or pushed-back pin between the controller and the fuel level sensor
- Fuel level sensor coil, element or sensor internally open
Checks
- 1Unplug the fuel level sensor and measure across its pins, an open reading means the part is faulty
- 2Check continuity of each wire from the fuel level sensor plug to the controller pin
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB P1293Fuel filter clogging sensor low voltage
Fuel filter clogging sensor low voltage. The reading or voltage for the fuel filter clogging sensor is below the allowed range, so the controller treats the signal as unreliable.· Shorted lowShorted lowCheck soonCauses
- Fuel filter clogging sensor signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the fuel filter clogging sensor value on live data and compare it with the expected value
- 2Unplug the fuel filter clogging sensor and check the signal wire for a short to ground and the supply for 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JCB P1294Fuel filter clogging sensor high voltage
Fuel filter clogging sensor high voltage. The reading or voltage for the fuel filter clogging sensor is above the allowed range, so the controller treats the signal as unreliable.· Shorted highShorted highCheck soonCauses
- Fuel filter clogging sensor signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the fuel filter clogging sensor value on live data and compare it with the expected value
- 2Unplug the fuel filter clogging sensor and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
JCB B1303Fuel lift pump relay short circuit
The fuel lift pump relay circuit is shorted, so the ECU switches the output off. The lift pump may not run or may run all the time, causing a hard start, a stall or a drained battery.· Short circuitShort circuitCheck soonCauses
- Relay coil winding shorted
- Relay control wire shorted to ground or supply
- Water in the relay socket
Checks
- 1Swap the lift pump relay with a known good one of the same type
- 2Check the relay socket for burning and moisture
- 3Check the control wire for a short to ground or supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.
Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.
JCB B1304Fuel lift pump relay open circuit
The fuel lift pump relay circuit is open, so the ECU cannot drive the relay. The lift pump will not run, so the engine may crank but not start, or lose fuel and stall.· Open circuitOpen circuitCheck soonCauses
- Relay coil open
- Relay control wire broken or pin backed out
- Corroded relay socket
Checks
- 1Swap the relay with a known good one and see if the pump runs
- 2Check the relay coil resistance for an open circuit
- 3Check the control wire for continuity back to the ECU
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
JCB P2264Water in fuel sensor feedback signal ADC fault
Water in fuel sensor feedback signal ADC fault. The controller logged a fault on the water in fuel sensor feedback signal ADC, which affects how the fuel filter or water-in-fuel sensor works until the cause is found.· OtherOtherCheck soonCauses
- Water in fuel sensor feedback signal ADC or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the water in fuel sensor feedback signal ADC and look for a value that is stuck or implausible
- 2Check the water in fuel sensor feedback signal ADC connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2265Water in fuel sensor plausibility fault
Water in fuel sensor plausibility fault. The controller sees the water in fuel sensor plausibility behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Water in fuel sensor plausibility drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the water in fuel sensor plausibility circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the water in fuel sensor plausibility value on live data with a known good value or a reference gauge
- 2Check the water in fuel sensor plausibility connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P2266Water in fuel sensor signal low
Water in fuel sensor signal low. The reading or voltage for the water in fuel sensor is below the allowed range, so the controller treats the signal as unreliable.· OtherOtherCheck soonCauses
- Water in fuel sensor signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the water in fuel sensor value on live data and compare it with the expected value
- 2Unplug the water in fuel sensor and check the signal wire for a short to ground and the supply for 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2267Water in fuel sensor signal high
Water in fuel sensor signal high. The reading or voltage for the water in fuel sensor is above the allowed range, so the controller treats the signal as unreliable.· OtherOtherCheck soonCauses
- Water in fuel sensor signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the water in fuel sensor value on live data and compare it with the expected value
- 2Unplug the water in fuel sensor and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2269Water in fuel detected
Water in fuel detected. The controller logged a fault on the water in fuel detected, which affects how the fuel filter or water-in-fuel sensor works until the cause is found.· OtherOtherCheck soonCauses
- Water in fuel detected or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the water in fuel detected and look for a value that is stuck or implausible
- 2Check the water in fuel detected connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Listen for the lift pump priming for a few seconds when the key goes on
- 2Drain the water from the filter bowl and see whether the warning clears
- 3Compare the gauge reading with the real fuel level seen through the filler
- 4Check the pump fuse and relay, and swap the relay with a known good one
- 5Check the filter service history and replace the filter if due
- 6Measure the sender resistance at empty and full and check it moves smoothly
- 7Measure supply voltage at the pump connector while the pump is commanded on
Causes
- Lift pump motor failed or drawing too much current
- Water collected in the filter bowl
- Fuel sender float stuck or resistor track worn
- Lift pump relay or fuse faulty
Most common here: open circuit (3 of 17)
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
When to stop
You'll notice: The engine may crank but not start, or lose power and stall under load because the high-pressure pump is not being fed.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Partao JCB fault code list, page 8 (code table)
- Partao JCB fault code list, page 2 (code table)
- Partao JCB fault code list, page 9 (code table)
- Partao JCB fault code list, page 1 (code table)
- Partao JCB fault code list, page 13 (code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.