JCB · Engine ECU (Dieselmax / Ecomax) - aftertreatment
JCB DPF pressure, regeneration and exhaust temperature sensors fault codes
The differential pressure sensor measures the pressure drop across the diesel particulate filter so the ECU can estimate soot load. The DPF traps soot and the ECU burns it off in regeneration.
More about these partsLess
These codes report regeneration that is incomplete, too frequent, or too much soot or ash in the filter. Temperature sensors in the exhaust and SCR catalyst (including T4) let the ECU control regeneration and SCR dosing.
Where this code shows
Switch the key on and note any warning lamp or fault icon on the cluster.
What do these codes mean?
JCB codes P242F to P3422-87 are all about the dPF pressure, regeneration and exhaust temperature sensors. The most common failure type is lost message (4 of 22); none needs an immediate stop. Start with this check: check the sensor pipes for blockage or leaks (on the DPF differential pressure sensor, with the diagnostic tool and a multimeter).
How urgent are they?
None of the 22 codes here means stop now; all 22 can wait until the shift ends, but find the cause before the next one.
- Check soon22
What should I check first?
Check the sensor pipes for blockage or leaks (on the DPF differential pressure sensor, with the diagnostic tool and a multimeter)
Shared checks22 of 22
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
JCB P242FDPF soot load high due to ash buildup
DPF soot load high due to ash buildup. The reading or voltage for the DPF soot load high due to ash buildup is above the allowed range, so the controller treats the signal as unreliable.· OtherOtherCheck soonCauses
- DPF soot load high due to ash buildup signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the DPF soot load high due to ash buildup value on live data and compare it with the expected value
- 2Unplug the DPF soot load high due to ash buildup and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P242B-00SCR catalyst upstream temperature sensor plausibility error
The SCR catalyst upstream temperature sensor reading fails a plausibility check: it does not match the temperatures around it.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Upstream SCR temperature sensor drifted or damaged
- Corrosion in its plug
Checks
- 1Compare the upstream temperature with the downstream and exhaust values
- 2Inspect the sensor and its plug
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P242B-16Catalyst temperature sensor plausibility below minimum threshold
The catalyst temperature sensor reading is plausible only below its minimum threshold: the value is lower than the catalyst could be after the engine has been running.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Sensor shorted or reading low
- Sensor fitted in the wrong place or loose in its boss
Checks
- 1Check the sensor for firm mounting and a clean plug
- 2Compare with the other catalyst temperature values after warm-up
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P242C-16T4 exhaust catalyst temperature voltage signal below minimum
The T4 exhaust catalyst temperature sensor voltage is below its minimum, a short toward ground in the sensor circuit or the sensor itself.· OtherOtherCheck soonCauses
- T4 signal wire shorted to ground
- T4 sensor shorted internally
Checks
- 1Unplug the T4 sensor; if the voltage rises, the sensor is the short, if not the wire
- 2Check the lead for heat or chafe damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P242B-17Catalyst temperature sensor plausibility above maximum threshold
The catalyst temperature sensor plausibility is above its maximum threshold: the value is higher than the catalyst can be, so it is rejected.· Lost messageLost messageCheck soonCauses
- Sensor open circuit reading high
- Heat damage to the sensor lead
Checks
- 1Inspect the sensor lead near the exhaust for heat damage
- 2Compare the value with other exhaust temperature sensors
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P242D-17T4 exhaust catalyst temperature voltage signal above maximum
The T4 exhaust catalyst temperature sensor voltage is above its maximum, which points to an open circuit or a short to supply in the T4 circuit.· Shorted highShorted highCheck soonCauses
- T4 sensor open or unplugged
- T4 signal wire shorted to a supply
Checks
- 1Check continuity of the T4 signal wire to the ECU
- 2Inspect the plug for a pushed-back pin
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
JCB P242B-23T4 exhaust catalyst temperature signal below minimum
The T4 exhaust catalyst temperature signal is below its minimum value, as if the catalyst were cold when it should be warm.· OtherOtherCheck soonCauses
- T4 sensor shorted or damaged
- Poor connection at the T4 plug
Checks
- 1Check the T4 sensor resistance against a reference at a known temperature
- 2Inspect the plug and lead
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P1455DPF particulate over limit
The soot load in the diesel particulate filter has gone beyond the allowed limit. Expect a DPF warning lamp, reduced engine power and eventually limp mode until the filter is regenerated or cleaned.· OtherOtherCheck soonCauses
- Soot load beyond the limit because several regeneration attempts failed
- Short working cycles that never let the exhaust get hot enough
- Differential pressure sensor or its pipes blocked or leaking
Checks
- 1Read the live soot load and regeneration history with the diagnostic tool
- 2Start a forced regeneration and watch exhaust temperatures rise
- 3Check the pressure sensor pipes for blockage and cracks
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P1471DPF regeneration defective
The diesel particulate filter is not regenerating properly. Soot builds up and power may drop or limp mode starts.· OtherOtherCheck soonCauses
- Machine used at low load and temperature for long periods so passive regeneration cannot occur
- Regeneration interrupted too often by the operator switching the engine off
- Faulty exhaust temperature sensor or differential pressure sensor misleading the ECU
- Fuel injection or EGR fault leaving too much soot
- Blocked or damaged DPF
Checks
- 1Read the soot load and the regeneration status live with the diagnostic tool
- 2Run a forced (parked) regeneration if the soot level allows
- 3Check the exhaust temperature and differential pressure sensors and their hoses
- 4Look for injector, EGR or turbo faults that raise soot production
- 5Check engine oil level and condition, since oil in the exhaust blocks the filter
- 6Inspect the DPF for damage or ash blockage if regeneration does not work
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2080Exhaust gas temperature sensor range/performance
The exhaust gas temperature sensor reading does not follow what the engine is doing, so the ECU rates it out of range or performance. It may be stuck, slow or offset.· OtherOtherCheck soonCauses
- Sensor stuck or slow to respond
- Offset caused by a corroded plug
Checks
- 1Compare the exhaust temperature with the other exhaust sensors and with engine load on live data
- 2Check the plug pins for corrosion
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2428Exhaust gas temperature too high
The ECU measured exhaust gas temperature above the allowed limit. This can be a real overheat from a blocked filter or a long regeneration, not just a sensor fault.· Lost messageLost messageCheck soonCauses
- Exhaust genuinely too hot, for example from a blocked DPF or a regeneration running too long
- Sensor reading high because of a wiring fault
Checks
- 1Check the DPF soot load and the regeneration history
- 2Compare the temperature with other exhaust sensors to confirm it is real
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P2428-17Exhaust catalyst temperature T4 signal above maximum limit
The exhaust catalyst temperature T4 signal is above its maximum limit. T4 sits at the SCR catalyst, so a high reading may be real heat or a wiring fault.· OtherOtherCheck soonCauses
- T4 sensor open or reading high from a wiring fault
- Exhaust really too hot at the catalyst
Checks
- 1Compare T4 with the other exhaust temperatures on live data
- 2Check the T4 sensor and its connector
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P2452DPF differential pressure too low
DPF differential pressure too low. The reading or voltage for the DPF differential pressure too is below the allowed range, so the controller treats the signal as unreliable.· Real conditionReal conditionCheck soonCauses
- DPF differential pressure too signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the DPF differential pressure too value on live data and compare it with the expected value
- 2Unplug the DPF differential pressure too and check the signal wire for a short to ground and the supply for 5 V
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P2453DPF differential pressure too high
DPF differential pressure too high. The reading or voltage for the DPF differential pressure too is above the allowed range, so the controller treats the signal as unreliable.· Real conditionReal conditionCheck soonCauses
- DPF differential pressure too signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the DPF differential pressure too value on live data and compare it with the expected value
- 2Unplug the DPF differential pressure too and check the signal wire for a short to 5 V or battery
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
JCB P2454DPF differential pressure sensor voltage too low
DPF differential pressure sensor voltage too low. The reading or voltage for the DPF differential pressure sensor voltage too is below the allowed range, so the controller treats the signal as unreliable.· Shorted lowShorted lowCheck soonCauses
- DPF differential pressure sensor voltage too signal pulled low by a short to ground or an open supply
- Sensor or part failed giving a low reading
Checks
- 1Read the DPF differential pressure sensor voltage too value on live data and compare it with the expected value
- 2Unplug the DPF differential pressure sensor voltage too and check the signal wire for a short to ground and the supply for 5 V
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
JCB P2455DPF differential pressure sensor voltage high
DPF differential pressure sensor voltage high. The reading or voltage for the DPF differential pressure sensor is above the allowed range, so the controller treats the signal as unreliable.· Shorted highShorted highCheck soonCauses
- DPF differential pressure sensor signal pulled high by a short to the 5 V reference or supply
- Sensor or part failed giving a high reading
Checks
- 1Read the DPF differential pressure sensor value on live data and compare it with the expected value
- 2Unplug the DPF differential pressure sensor and check the signal wire for a short to 5 V or battery
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
JCB P2456DPF differential pressure sensor zero-point learning failure
DPF differential pressure sensor zero-point learning failure. The controller sees the DPF differential pressure sensor zero behaving outside what it expects, so it logs a range, plausibility or performance fault.· Erratic or implausibleErratic or implausibleCheck soonCauses
- DPF differential pressure sensor zero drifting or worn so it no longer matches the real condition
- Poor connection or high resistance in the DPF differential pressure sensor zero circuit
- A related fault elsewhere making this reading look wrong
Checks
- 1Compare the DPF differential pressure sensor zero value on live data with a known good value or a reference gauge
- 2Check the DPF differential pressure sensor zero connector and wiring for high resistance and intermittent contact
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
JCB P2458DPF regeneration timeouts too frequent
DPF regeneration timeouts too frequent. The controller did not receive a valid message or lost contact on the bus, so data for the diesel particulate filter regeneration is missing or unreliable.· Lost messageLost messageCheck soonCauses
- CAN wiring open, shorted or wet at a connector
- The sending module not powered, reset or faulty
Checks
- 1Check the CAN high and low wiring and the 120 ohm termination
- 2Check that the sending module has power, earth and no active faults of its own
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P3419-87Error for particulate inlet pressure
Error for particulate inlet pressure. The controller logged a fault on the error for particulate inlet pressure, which affects how the diesel particulate filter regeneration works until the cause is found.· OtherOtherCheck soonCauses
- Error for particulate inlet pressure or its wiring faulty
- Connector corrosion or a loose pin
Checks
- 1Read the live data for the error for particulate inlet pressure and look for a value that is stuck or implausible
- 2Check the error for particulate inlet pressure connector and wiring for damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3420-87Data length error for PROSCR3 regeneration frame
Data length error for PROSCR3 regeneration frame. The controller did not receive a valid message or lost contact on the bus, so data for the diesel particulate filter regeneration is missing or unreliable.· OtherOtherCheck soonCauses
- CAN wiring open, shorted or wet at a connector
- The sending module not powered, reset or faulty
Checks
- 1Check the CAN high and low wiring and the 120 ohm termination
- 2Check that the sending module has power, earth and no active faults of its own
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
JCB P3421-87Timeout error for PROSCR3 regeneration frame
Timeout error for PROSCR3 regeneration frame. The controller did not receive a valid message or lost contact on the bus, so data for the diesel particulate filter regeneration is missing or unreliable.· Lost messageLost messageCheck soonCauses
- CAN wiring open, shorted or wet at a connector
- The sending module not powered, reset or faulty
Checks
- 1Check the CAN high and low wiring and the 120 ohm termination
- 2Check that the sending module has power, earth and no active faults of its own
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
JCB P3422-87Erroneous soot load message signal
Erroneous soot load message signal. The controller did not receive a valid message or lost contact on the bus, so data for the diesel particulate filter regeneration is missing or unreliable.· OtherOtherCheck soonCauses
- CAN wiring open, shorted or wet at a connector
- The sending module not powered, reset or faulty
Checks
- 1Check the CAN high and low wiring and the 120 ohm termination
- 2Check that the sending module has power, earth and no active faults of its own
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Check the sensor pipes for blockage or leaks (on the DPF differential pressure sensor, with the diagnostic tool and a multimeter)
- 2Check for other engine or sensor faults that stop regeneration
- 3Check the sensor resistance against the manual
- 4Compare the reading with the engine off, it should be near zero
- 5Run a forced regeneration with the diagnostic tool when allowed
- 6Check the connector and wiring (on the exhaust temperature sensors, with the diagnostic tool and a multimeter)
- 7Check the supply and signal at the plug (on the DPF differential pressure sensor, with the diagnostic tool and a multimeter)
Causes
- Sensor failed
- Machine used for short or light-load work so the DPF does not get hot enough
- Blocked or leaking sensor pipes
- Blocked or damaged DPF
Most common here: lost message (4 of 22)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: A DPF or check lamp may come on and regeneration may be requested too often.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Partao JCB fault code list, page 14 (code table)
- Partao JCB fault code list, page 13 (code table)
- Partao JCB fault code list, page 9 (code table)
- Partao JCB fault code P1471 page
- Partao JCB fault code list, page 11 (code table)
- Partao JCB fault code list, page 15 (code table)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.