EF Logo

JCB · Machine controller (MECU / DECU)

JCB Lights, indicators, alarms and relays fault codes

The controller drives the interior light, turn indicators, hazard, rear fog, reverse and brake lights, the travel alarm and the refuelling pump relay.

FaultCheckC132DJCB · Lights, indicators, alarms and relays
Code shows hereFAULTC132D

Where this code shows

Switch the key on and note any warning lamp or fault icon on the cluster.

What do these codes mean?

JCB codes C132D to C1348 are all about the lights, indicators, alarms and relays. The most common failure type is short circuit (9 of 18); none needs an immediate stop. Start with this check: check the bulb or device on the light, alarm or relay output output works when connected to a known good supply.

How urgent are they?

None of the 18 codes here means stop now; all 18 can wait until the shift ends, but find the cause before the next one.

  • Check soon18

What should I check first?

Check the bulb or device on the light, alarm or relay output output works when connected to a known good supply

Shared checks

18 of 18

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JCB C132DLeft turn indicator output open circuit

    The controller finds no current in the left turn indicator output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the left turn indicator circuit failed open
    • Wire broken or connector pin corroded
    • Left indicator flasher output weak
    • Steering column stalk contacts dirty

    Checks

    1. 1Check the left turn indicator bulb, buzzer or relay first, then the wiring to it
    2. 2Check the left turn indicator circuit feed and earth at the load
    3. 3Check the left front and left rear indicator bulbs separately
    4. 4Switch on the left indicator and measure the pulses at the lamp.
    5. 5Operate the stalk through its detents and watch the signal on live data
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C132ELeft turn indicator output short circuit

    The controller found the left turn indicator output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the left turn indicator lamps chafed against the body or frame
    • A lamp, buzzer or relay in the left turn indicator circuit shorted
    • Left indicator lamp base wet
    • Indicator lamp lens filled with water

    Checks

    1. 1Unplug the load of the left turn indicator circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the left turn indicator wiring for rubbed insulation or water in a connector
    3. 3Look at the left indicator lamp base for water, which gives a leak path
    4. 4Switch on the left indicator and measure the current drawn.
    5. 5Shake the lamp lens for water and look for a split gasket
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB C132FRight turn indicator output open circuit

    The controller finds no current in the right turn indicator output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the right turn indicator circuit failed open
    • Wire broken or connector pin corroded
    • Right indicator flasher output weak
    • Steering column stalk contacts dirty

    Checks

    1. 1Check the right turn indicator bulb, buzzer or relay first, then the wiring to it
    2. 2Check the right turn indicator circuit feed and earth at the load
    3. 3Check the right front and right rear indicator bulbs separately
    4. 4Switch on the right indicator and measure the pulses at the lamp.
    5. 5Operate the stalk through its detents and watch the signal on live data
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB B1307Short circuit in interior illumination circuit

    The controller found the interior illumination output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the cab interior lamp chafed against the body or frame
    • A lamp, buzzer or relay in the interior illumination circuit shorted
    • Interior lamp switch contacts worn
    • Roof console connector loosened by cab vibration

    Checks

    1. 1Unplug the load of the interior illumination circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the interior illumination wiring for rubbed insulation or water in a connector
    3. 3Check the interior lamp's own switch position and the dome lamp fuse
    4. 4Test the cab lamp with its own switch in all three positions.
    5. 5Open the roof console and reseat the lamp connector behind the headliner
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB B1308Interior illumination open circuit or bulb failure

    The controller finds no current in the interior illumination output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the interior illumination circuit failed open
    • Wire broken or connector pin corroded
    • Interior bulb filament broken
    • Courtesy lamp lens assembly with a dead LED board

    Checks

    1. 1Check the interior illumination bulb, buzzer or relay first, then the wiring to it
    2. 2Check the interior illumination circuit feed and earth at the load
    3. 3Replace the interior bulb with a known good one before chasing the wiring
    4. 4Look at the door switch signal, which brings the lamp on when the door opens.
    5. 5Swap the lamp assembly with a spare to separate lamp from wiring
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1311Travel alarm circuit short circuit

    The controller found the travel alarm output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the travel alarm that sounds when moving chafed against the body or frame
    • A lamp, buzzer or relay in the travel alarm circuit shorted
    • Travel alarm membrane or coil damaged
    • Horn-type sounder diaphragm cracked

    Checks

    1. 1Unplug the load of the travel alarm circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the travel alarm wiring for rubbed insulation or water in a connector
    3. 3Check the alarm's mounting and its sound outlet for a blockage
    4. 4Move the machine slowly and listen for the alarm tone at the rear.
    5. 5Remove the sounder, bench-power it from a battery and listen
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB C1312Travel alarm circuit open circuit

    The controller finds no current in the travel alarm output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the travel alarm circuit failed open
    • Wire broken or connector pin corroded
    • Travel alarm lead pulled out at the alarm
    • Sounder plug corroded at the rear bracket

    Checks

    1. 1Check the travel alarm bulb, buzzer or relay first, then the wiring to it
    2. 2Check the travel alarm circuit feed and earth at the load
    3. 3Test the alarm by feeding it 12 V directly from a fused lead
    4. 4Check the alarm tone at the rear while an assistant selects reverse.
    5. 5Clean the sounder plug and apply contact grease
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1313Refuelling pump relay short circuit

    The controller found the refuelling pump relay output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the relay that powers the refuelling pump chafed against the body or frame
    • A lamp, buzzer or relay in the refuelling pump relay circuit shorted
    • Refuelling relay contacts welded by repeated load
    • Pump motor winding drawing high current

    Checks

    1. 1Unplug the load of the refuelling pump relay circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the refuelling pump relay wiring for rubbed insulation or water in a connector
    3. 3Check the pump relay base and the pump motor brushes
    4. 4Test the refuelling pump relay with the pump switch while listening for a click.
    5. 5Measure the pump motor current when it runs from a separate supply
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB C1314Refuelling pump relay open circuit

    The controller finds no current in the refuelling pump relay output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the refuelling pump relay circuit failed open
    • Wire broken or connector pin corroded
    • Refuelling relay coil burnt out
    • Fuel pump fuse of the wrong rating or blown

    Checks

    1. 1Check the refuelling pump relay bulb, buzzer or relay first, then the wiring to it
    2. 2Check the refuelling pump relay circuit feed and earth at the load
    3. 3Swap the refuelling relay with an identical relay from another circuit
    4. 4Measure the relay coil while the pump switch is on.
    5. 5Replace the pump fuse and look for what blew it
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1330Right turn indicator output short circuit

    The controller found the right turn indicator output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the right turn indicator lamps chafed against the body or frame
    • A lamp, buzzer or relay in the right turn indicator circuit shorted
    • Right indicator lamp base wet
    • Indicator lamp lens filled with water

    Checks

    1. 1Unplug the load of the right turn indicator circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the right turn indicator wiring for rubbed insulation or water in a connector
    3. 3Look at the right indicator lamp base for water, which gives a leak path
    4. 4Switch on the right indicator and measure the current drawn.
    5. 5Shake the lamp lens for water and look for a split gasket
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB C1331Rear fog lights output open circuit

    The controller finds no current in the rear fog light output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the rear fog light circuit failed open
    • Wire broken or connector pin corroded
    • Fog lamp bulb broken by vibration
    • Fog lamp mounted on a flexing bracket that fatigues the lead

    Checks

    1. 1Check the rear fog light bulb, buzzer or relay first, then the wiring to it
    2. 2Check the rear fog light circuit feed and earth at the load
    3. 3Check the fog lamp bulb type and the lamp earth
    4. 4Switch on the fog lights and measure voltage at the lamp socket.
    5. 5Flex the fog lamp lead at the bracket while the lamp is switched on
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1332Rear fog lights output short circuit

    The controller found the rear fog light output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the rear fog lights chafed against the body or frame
    • A lamp, buzzer or relay in the rear fog light circuit shorted
    • Fog lamp lead pinched at the lamp cluster
    • Fog lamp lead rubbing on the engine cover edge

    Checks

    1. 1Unplug the load of the rear fog light circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the rear fog light wiring for rubbed insulation or water in a connector
    3. 3Inspect the fog lamp wiring at the rear lamp cluster for a pinched lead
    4. 4Switch on the fog lights and check whether the fuse blows.
    5. 5Run the fog lamp lead by hand along the engine cover edge for damage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB C1333Reverse lights output open circuit

    The controller finds no current in the reverse light output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the reverse light circuit failed open
    • Wire broken or connector pin corroded
    • Reverse lamp bulb blown
    • Reverse lamp plug filled with mud from the track

    Checks

    1. 1Check the reverse light bulb, buzzer or relay first, then the wiring to it
    2. 2Check the reverse light circuit feed and earth at the load
    3. 3Check the reverse lamp bulb and the reverse switch signal from the transmission
    4. 4Select reverse and measure voltage at the reverse lamp plug.
    5. 5Wash and dry the reverse lamp plug and re-test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1334Reverse lights output short circuit

    The controller found the reverse light output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the reverse lights chafed against the body or frame
    • A lamp, buzzer or relay in the reverse light circuit shorted
    • Reverse lamp lead cut at the counterweight
    • Counterweight edge cutting the reverse lamp lead

    Checks

    1. 1Unplug the load of the reverse light circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the reverse light wiring for rubbed insulation or water in a connector
    3. 3Inspect the wiring in the rear of the machine where the reverse lamp lead passes the counterweight
    4. 4Select reverse and see whether the fuse for the reverse light blows.
    5. 5Check the lead where it passes the counterweight lip
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB C1341Hazard LED output open circuit

    The controller finds no current in the hazard LED output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the hazard LED circuit failed open
    • Wire broken or connector pin corroded
    • Hazard switch LED failed
    • Hazard switch bezel pressed too hard on its LED

    Checks

    1. 1Check the hazard LED bulb, buzzer or relay first, then the wiring to it
    2. 2Check the hazard LED circuit feed and earth at the load
    3. 3Check the hazard switch LED and its plug in the switch panel
    4. 4Press the hazard switch and measure the LED voltage at the switch plug.
    5. 5Remove the hazard switch from the panel and test the LED on the bench
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1342Hazard LED output short circuit

    The controller found the hazard LED output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the hazard switch indicator LED chafed against the body or frame
    • A lamp, buzzer or relay in the hazard LED circuit shorted
    • Hazard switch panel lead pinched
    • Panel wiring crushed by a switch refit

    Checks

    1. 1Unplug the load of the hazard LED circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the hazard LED wiring for rubbed insulation or water in a connector
    3. 3Look at the hazard switch panel for a pinched lead behind the switch
    4. 4Press the hazard switch and check the fuse.
    5. 5Look behind the switch panel for pinched wiring after any recent refit
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • JCB C1347Brake light output open circuit

    The controller finds no current in the brake light output, an open circuit or a failed load.· Open circuit
    Check soon

    Causes

    • A bulb, buzzer or relay in the brake light circuit failed open
    • Wire broken or connector pin corroded
    • Brake light bulb blown
    • Brake pedal switch out of adjustment

    Checks

    1. 1Check the brake light bulb, buzzer or relay first, then the wiring to it
    2. 2Check the brake light circuit feed and earth at the load
    3. 3Check the brake light switch operation on the pedal and the bulb
    4. 4Press the brake pedal and measure voltage at the brake lamp plug.
    5. 5Adjust or replace the brake pedal switch and recheck the signal
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • JCB C1348Brake light output short circuit

    The controller found the brake light output shorted and drawing too much current, so it shut the output off.· Short circuit
    Check soon

    Causes

    • Wire to the brake lights chafed against the body or frame
    • A lamp, buzzer or relay in the brake light circuit shorted
    • Brake light lead pinched near the lamp
    • Tail light assembly seal broken, letting water in

    Checks

    1. 1Unplug the load of the brake light circuit; if the fault clears, the load was shorted, if not, the wire is
    2. 2Inspect the brake light wiring for rubbed insulation or water in a connector
    3. 3Inspect the brake light wiring at the rear lamp cluster for a pinched lead
    4. 4Press the brake pedal and check whether the fuse blows.
    5. 5Open the tail light assembly and look for corrosion inside
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

Shared checks

Checks, in order

  1. 1Check the bulb or device on the light, alarm or relay output output works when connected to a known good supply
  2. 2Check the wiring to the light, alarm or relay output for opens, shorts to ground or battery, and chafing
  3. 3Check the light, alarm or relay output relay and its fuse and swap it with a known good relay
  4. 4Measure the light, alarm or relay output output at the plug while commanding it on the diagnostic tool

Causes

  • Bulb or device failed
  • Wiring fault
  • Relay failed
  • Output fault

Most common here: short circuit (9 of 18)

Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

When to stop

You'll notice: A light, alarm or the refuelling pump may not work.

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.