J1939 · Aftertreatment - DPF
SPN 3246 Fault Code
Aftertreatment 1 diesel particulate filter outlet gas temperature
What does SPN 3246 mean?
Exhaust temperature leaving the DPF, read by a sensor at the filter outlet. The ECM uses it to manage regeneration and to protect downstream parts. How urgent it is depends on the FMI after SPN 3246 - pick it below. Check first: compare the outlet temperature with the DPF inlet reading; outside a regeneration the two should be close.
- SPN 3246
- Aftertreatment 1 diesel particulate filter outlet gas temperature
- FMI ?
- How it failed - the number after the SPN
Can I keep running with it?
Depends on the FMI
How urgent it is depends on the FMI after SPN 3246 - pick it below.
What should I check first?
Compare the outlet temperature with the DPF inlet reading; outside a regeneration the two should be close
Then 4 more checksWhere to read it
Connect a J1939-capable scan tool to the 9-pin diagnostic port.
Which FMI shows after SPN 3246?
You'll notice: The ECM cannot see the gas temperature leaving the particulate filter, so it cannot tell whether a regeneration is burning soot safely.
Find the number shown after SPN 3246 on your display. 2 of them have their own page with causes and checks.
- 0SPN 3246 FMI 0: Value is above the normal range, most severe levelReal conditionCummins ISX15, Detroit DD15, Detroit DD13, Detroit DD13 Gen 5 and 1 more
- 2SPN 3246 FMI 2: Data is erratic, intermittent or incorrectErratic or implausibleCummins ISX15, Detroit DD15, Detroit DD13, Detroit DD13 Gen 5 and 1 more
- 3SPN 3246 FMI 3: Signal voltage is above normal, or the circuit is shorted to a high sourceShorted highCummins ISX15, Detroit DD15, Detroit DD13, Detroit DD13 Gen 5 and 1 more
- 4SPN 3246 FMI 4: Signal voltage is below normal, or the circuit is shorted to a low sourceShorted lowCummins ISX15, Detroit DD15, Detroit DD13, Detroit DD13 Gen 5 and 1 more
- 7SPN 3246 FMI 7: Outlet temperature sensor is not respondingPart or controllerDetroit DD15
- 8SPN 3246 FMI 8: Outlet temperature signal shows a spikeErratic or implausibleDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
- 15SPN 3246 FMI 15: Value is above the normal range, least severe levelReal conditionCummins ISX15
- 16SPN 3246 FMI 16: Value is above the normal range, moderately severe levelReal conditionCummins ISX15
- 20SPN 3246 FMI 20: Outlet temperature sensor is stuckErratic or implausibleDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
- 21SPN 3246 FMI 21: Outlet temperature sensor reading is not plausibleErratic or implausibleDetroit DD15, Detroit DD13, Detroit DD13 Gen 5, Detroit DD15 Gen 5
Checks
0 of 5 done
When to stop
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
How urgent SPN 3246 is depends on its FMI and whether the engine has derated. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Causes
- Reads cold: an open circuit or a short to supply in the DPF outlet temperature sensor wiring, which the ECM reads as an extremely low temperature
- Reads hot: signal wire shorted to ground or the DPF outlet temperature sensor element shorted, which the ECM reads as an extremely high temperature
- Real condition: regeneration not reaching full temperature, so the outlet stays cold and the soot is not burning
- Real condition: dPF canister damaged or melted, so outlet gas temperature runs off the expected curve
1 more causeFewer causes
- Sensor: outlet temperature lagging the inlet during regeneration because the filter holds heat
Other Aftertreatment - DPF codes
Source
Cummins ISX15 2013-2018 fault codes list (Diesel Laptops)
This list names SPN 3246 and the FMIs above for the engines it covers. The guidance on this page is general, not taken from it.
The source covers: Cummins ISX15 (2013-2018) and X15; same SPN on other J1939 engines.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.