Hyundai · Excavator pressure sensor codes (HCESPN)
Hyundai Excavator pump and control pressure sensors fault codes
These HCESPN codes cover the main pump P1 and P2 pressure sensors, the pilot pump P3 pressure sensor, the overload pressure sensor and the two negative feedback pressure sensors on -9 series excavators. The MCU uses them for pump flow control and engine speed matching.
Where this code shows
Turn the key on and open the fault code or diagnosis menu on the cluster.
What do these codes mean?
Hyundai codes 120-0 to 125-4 are all about the excavator pump and control pressure sensors. Most are lost message faults; none needs an immediate stop. Start with this check: compare the cluster reading with a test gauge on the matching pressure port before replacing a sensor.
How urgent are they?
None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.
- Check soon24
What should I check first?
Compare the cluster reading with a test gauge on the matching pressure port before replacing a sensor
Shared checks24 of 24
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Hyundai 120-0Main pump P1 pressure sensor data above normal range
The MCU reads the Main pump P1 pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It reports the front main pump outlet pressure. On a two-pump system this is the front pump line, so a bad reading can make the MCU cut flow or raise engine speed when it should not, and the circuits that sit on this pump feel slow. Typical clues are a machine that digs normally with the front pump circuits but lacks power when several functions are combined, and a P1 reading that sits well apart from P2 at the same engine speed. Also compare the reading at idle against a gauge at the same port. Plugged tubing, a collapsed hose, contaminated oil or a sticking swashplate regulator often hides behind a believable but wrong figure. Pump drive coupling slip or a damaged spline can also produce odd readings.· Lost messageLost messageCheck soonCauses
- Real P1 pressure above normal: regulator or relief stuck
- Open signal or ground wire at the the P1 pump pressure sensor connector
- the P1 pump pressure sensor failed and reading high
Checks
- 1Read the Main pump P1 value on the cluster and compare it with a test gauge on the P1 pump outlet before blaming the sensor
- 2Unplug the P1 pump pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Compare the P1 reading with P2 while working a function: two similar pumps should read similarly
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 120-1Main pump P1 pressure sensor data below normal range
The MCU reads the Main pump P1 pressure sensor below its normal range, so the pressure it expects on the P1 pump outlet is not showing up in the signal. It reports the front main pump outlet pressure. On a two-pump system this is the front pump line, so a bad reading can make the MCU cut flow or raise engine speed when it should not, and the circuits that sit on this pump feel slow. Typical clues are a machine that digs normally with the front pump circuits but lacks power when several functions are combined, and a P1 reading that sits well apart from P2 at the same engine speed. Also compare the reading at idle against a gauge at the same port. Plugged tubing, a collapsed hose, contaminated oil or a sticking swashplate regulator often hides behind a believable but wrong figure. Pump drive coupling slip or a damaged spline can also produce odd readings.· Lost messageLost messageCheck soonCauses
- Low real pressure on the P1 pump outlet: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at the P1 pump pressure sensor
- the P1 pump pressure sensor drifted or failed low
Checks
- 1Compare the cluster Main pump P1 reading with a mechanical gauge on the P1 pump outlet; if the gauge is good the sensor or wiring is at fault
- 2Check the the P1 pump pressure sensor connector for water or green corrosion that adds resistance to the signal
- 3Compare the P1 reading with P2 while working a function: two similar pumps should read similarly
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 120-2Main pump P1 pressure sensor data error
The MCU decides the Main pump P1 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It reports the front main pump outlet pressure. On a two-pump system this is the front pump line, so a bad reading can make the MCU cut flow or raise engine speed when it should not, and the circuits that sit on this pump feel slow. Typical clues are a machine that digs normally with the front pump circuits but lacks power when several functions are combined, and a P1 reading that sits well apart from P2 at the same engine speed. Also compare the reading at idle against a gauge at the same port. Plugged tubing, a collapsed hose, contaminated oil or a sticking swashplate regulator often hides behind a believable but wrong figure. Pump drive coupling slip or a damaged spline can also produce odd readings.· Lost messageLost messageCheck soonCauses
- Intermittent contact in the the P1 pump pressure sensor connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- the P1 pump pressure sensor failing intermittently
Checks
- 1Watch the Main pump P1 reading while wiggling the harness at the P1 pump pressure sensor; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Compare the P1 reading with P2 while working a function: two similar pumps should read similarly
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 120-4Main pump P1 pressure sensor circuit voltage below normal
The MCU sees the Main pump P1 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It reports the front main pump outlet pressure. On a two-pump system this is the front pump line, so a bad reading can make the MCU cut flow or raise engine speed when it should not, and the circuits that sit on this pump feel slow. Typical clues are a machine that digs normally with the front pump circuits but lacks power when several functions are combined, and a P1 reading that sits well apart from P2 at the same engine speed. Also compare the reading at idle against a gauge at the same port. Plugged tubing, a collapsed hose, contaminated oil or a sticking swashplate regulator often hides behind a believable but wrong figure. Pump drive coupling slip or a damaged spline can also produce odd readings.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near the P1 pump pressure sensor
- the P1 pump pressure sensor shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug the P1 pump pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the the P1 pump pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
- 3Compare the P1 reading with P2 while working a function: two similar pumps should read similarly
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 121-0Main pump P2 pressure sensor data above normal range
The MCU reads the Main pump P2 pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It reports the rear main pump outlet pressure. This is the second pump line, so a bad reading mostly shows as weak swing or travel on the circuits fed by this pump while the front pump circuits still feel normal. Typical clues are normal front attachment speed with a weak travel or swing circuit, and a P2 reading that sits far from P1 when both pumps should be matched. Also compare the reading at idle against a gauge at the same port on the rear pump. Cavitation noise, overheated oil, worn pistons or a lazy flow regulator can produce a figure that disagrees with the demand. Swash plate bearing wear or a loose regulator linkage may play a part.· Lost messageLost messageCheck soonCauses
- Real P2 pressure above normal: regulator or relief stuck
- Open signal or ground wire at the the P2 pump pressure sensor connector
- the P2 pump pressure sensor failed and reading high
Checks
- 1Read the Main pump P2 value on the cluster and compare it with a test gauge on the P2 pump outlet before blaming the sensor
- 2Unplug the P2 pump pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Compare the P2 reading with P1 while working a function
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 121-1Main pump P2 pressure sensor data below normal range
The MCU reads the Main pump P2 pressure sensor below its normal range, so the pressure it expects on the P2 pump outlet is not showing up in the signal. It reports the rear main pump outlet pressure. This is the second pump line, so a bad reading mostly shows as weak swing or travel on the circuits fed by this pump while the front pump circuits still feel normal. Typical clues are normal front attachment speed with a weak travel or swing circuit, and a P2 reading that sits far from P1 when both pumps should be matched. Also compare the reading at idle against a gauge at the same port on the rear pump. Cavitation noise, overheated oil, worn pistons or a lazy flow regulator can produce a figure that disagrees with the demand. Swash plate bearing wear or a loose regulator linkage may play a part.· Lost messageLost messageCheck soonCauses
- Low real pressure on the P2 pump outlet: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at the P2 pump pressure sensor
- the P2 pump pressure sensor drifted or failed low
Checks
- 1Compare the cluster Main pump P2 reading with a mechanical gauge on the P2 pump outlet; if the gauge is good the sensor or wiring is at fault
- 2Check the the P2 pump pressure sensor connector for water or green corrosion that adds resistance to the signal
- 3Compare the P2 reading with P1 while working a function
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 121-2Main pump P2 pressure sensor data error
The MCU decides the Main pump P2 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It reports the rear main pump outlet pressure. This is the second pump line, so a bad reading mostly shows as weak swing or travel on the circuits fed by this pump while the front pump circuits still feel normal. Typical clues are normal front attachment speed with a weak travel or swing circuit, and a P2 reading that sits far from P1 when both pumps should be matched. Also compare the reading at idle against a gauge at the same port on the rear pump. Cavitation noise, overheated oil, worn pistons or a lazy flow regulator can produce a figure that disagrees with the demand. Swash plate bearing wear or a loose regulator linkage may play a part.· Lost messageLost messageCheck soonCauses
- Intermittent contact in the the P2 pump pressure sensor connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- the P2 pump pressure sensor failing intermittently
Checks
- 1Watch the Main pump P2 reading while wiggling the harness at the P2 pump pressure sensor; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Compare the P2 reading with P1 while working a function
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 121-4Main pump P2 pressure sensor circuit voltage below normal
The MCU sees the Main pump P2 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It reports the rear main pump outlet pressure. This is the second pump line, so a bad reading mostly shows as weak swing or travel on the circuits fed by this pump while the front pump circuits still feel normal. Typical clues are normal front attachment speed with a weak travel or swing circuit, and a P2 reading that sits far from P1 when both pumps should be matched. Also compare the reading at idle against a gauge at the same port on the rear pump. Cavitation noise, overheated oil, worn pistons or a lazy flow regulator can produce a figure that disagrees with the demand. Swash plate bearing wear or a loose regulator linkage may play a part.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near the P2 pump pressure sensor
- the P2 pump pressure sensor shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug the P2 pump pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the the P2 pump pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
- 3Compare the P2 reading with P1 while working a function
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 122-0Overload pressure sensor data above normal range
The MCU reads the Overload pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It reads the pressure used for the overload warning. The value feeds the overload warning, so a false reading either hides the warning when lifting too heavy a load or keeps the alarm and lamp active on an unloaded machine. A sensible check is to lift a known light load and a heavy load in turn and watch whether the overload number climbs smoothly instead of jumping or staying flat. Also watch for a reading that stays pegged while the machine is empty. Cold thick oil, a kinked sensing hose or a partly blocked orifice can distort the number while the load is genuine. A weeping fitting at the sensor port can leave oily residue on the plug.· Lost messageLost messageCheck soonCauses
- Real overload circuit pressure high: line blocked or valve stuck
- Open signal or ground wire at the the overload pressure sensor connector
- the overload pressure sensor failed and reading high
Checks
- 1Read the Overload value on the cluster and compare it with a test gauge on the overload warning circuit before blaming the sensor
- 2Unplug the overload pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Lift a load and see whether the overload pressure value rises with it
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 122-1Overload pressure sensor data below normal range
The MCU reads the Overload pressure sensor below its normal range, so the pressure it expects on the overload warning circuit is not showing up in the signal. It reads the pressure used for the overload warning. The value feeds the overload warning, so a false reading either hides the warning when lifting too heavy a load or keeps the alarm and lamp active on an unloaded machine. A sensible check is to lift a known light load and a heavy load in turn and watch whether the overload number climbs smoothly instead of jumping or staying flat. Also watch for a reading that stays pegged while the machine is empty. Cold thick oil, a kinked sensing hose or a partly blocked orifice can distort the number while the load is genuine. A weeping fitting at the sensor port can leave oily residue on the plug.· Lost messageLost messageCheck soonCauses
- Low real pressure on the overload warning circuit: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at the overload pressure sensor
- the overload pressure sensor drifted or failed low
Checks
- 1Compare the cluster Overload reading with a mechanical gauge on the overload warning circuit; if the gauge is good the sensor or wiring is at fault
- 2Check the the overload pressure sensor connector for water or green corrosion that adds resistance to the signal
- 3Lift a load and see whether the overload pressure value rises with it
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 122-2Overload pressure sensor data error
The MCU decides the Overload pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It reads the pressure used for the overload warning. The value feeds the overload warning, so a false reading either hides the warning when lifting too heavy a load or keeps the alarm and lamp active on an unloaded machine. A sensible check is to lift a known light load and a heavy load in turn and watch whether the overload number climbs smoothly instead of jumping or staying flat. Also watch for a reading that stays pegged while the machine is empty. Cold thick oil, a kinked sensing hose or a partly blocked orifice can distort the number while the load is genuine. A weeping fitting at the sensor port can leave oily residue on the plug.· Lost messageLost messageCheck soonCauses
- Intermittent contact in the the overload pressure sensor connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- the overload pressure sensor failing intermittently
Checks
- 1Watch the Overload reading while wiggling the harness at the overload pressure sensor; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Lift a load and see whether the overload pressure value rises with it
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 122-4Overload pressure sensor circuit voltage below normal
The MCU sees the Overload pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It reads the pressure used for the overload warning. The value feeds the overload warning, so a false reading either hides the warning when lifting too heavy a load or keeps the alarm and lamp active on an unloaded machine. A sensible check is to lift a known light load and a heavy load in turn and watch whether the overload number climbs smoothly instead of jumping or staying flat. Also watch for a reading that stays pegged while the machine is empty. Cold thick oil, a kinked sensing hose or a partly blocked orifice can distort the number while the load is genuine. A weeping fitting at the sensor port can leave oily residue on the plug.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near the overload pressure sensor
- the overload pressure sensor shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug the overload pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the the overload pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
- 3Lift a load and see whether the overload pressure value rises with it
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 123-0Negative feedback 1 pressure sensor data above normal range
The MCU reads the Negative feedback 1 pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It reports negative control pressure used in pump flow control. The negative control signal tells the pump regulator how much flow to give, so a wrong value can leave a pump stuck at minimum flow with sluggish speed or at full flow with heavy fuel burn. Look for a reading that never changes when the levers move, since a live negative control signal normally rises when levers return to neutral and drops as spools open. Also confirm the control line is free of restriction by checking its tube and filter. A clogged centre bypass tube, contaminated pilot oil or a stuck regulator spool commonly sits behind implausible control numbers. Inspect the regulator control ports for varnish and metal flakes.· Lost messageLost messageCheck soonCauses
- Real negative control pressure high: restricted return or stuck valve
- Open signal or ground wire at the negative feedback pressure sensor 1 connector
- negative feedback pressure sensor 1 failed and reading high
Checks
- 1Read the Negative feedback 1 value on the cluster and compare it with a test gauge on the negative feedback line of pump 1 before blaming the sensor
- 2Unplug negative feedback pressure sensor 1 and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Check the return line from the main valve for restriction
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 123-1Negative feedback 1 pressure sensor data below normal range
The MCU reads the Negative feedback 1 pressure sensor below its normal range, so the pressure it expects on the negative feedback line of pump 1 is not showing up in the signal. It reports negative control pressure used in pump flow control. The negative control signal tells the pump regulator how much flow to give, so a wrong value can leave a pump stuck at minimum flow with sluggish speed or at full flow with heavy fuel burn. Look for a reading that never changes when the levers move, since a live negative control signal normally rises when levers return to neutral and drops as spools open. Also confirm the control line is free of restriction by checking its tube and filter. A clogged centre bypass tube, contaminated pilot oil or a stuck regulator spool commonly sits behind implausible control numbers. Inspect the regulator control ports for varnish and metal flakes.· Lost messageLost messageCheck soonCauses
- Low real pressure on the negative feedback line of pump 1: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at negative feedback pressure sensor 1
- negative feedback pressure sensor 1 drifted or failed low
Checks
- 1Compare the cluster Negative feedback 1 reading with a mechanical gauge on the negative feedback line of pump 1; if the gauge is good the sensor or wiring is at fault
- 2Check the negative feedback pressure sensor 1 connector for water or green corrosion that adds resistance to the signal
- 3Check the return line from the main valve for restriction
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 123-2Negative feedback 1 pressure sensor data error
The MCU decides the Negative feedback 1 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It reports negative control pressure used in pump flow control. The negative control signal tells the pump regulator how much flow to give, so a wrong value can leave a pump stuck at minimum flow with sluggish speed or at full flow with heavy fuel burn. Look for a reading that never changes when the levers move, since a live negative control signal normally rises when levers return to neutral and drops as spools open. Also confirm the control line is free of restriction by checking its tube and filter. A clogged centre bypass tube, contaminated pilot oil or a stuck regulator spool commonly sits behind implausible control numbers. Inspect the regulator control ports for varnish and metal flakes.· Lost messageLost messageCheck soonCauses
- Intermittent contact in the negative feedback pressure sensor 1 connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- negative feedback pressure sensor 1 failing intermittently
Checks
- 1Watch the Negative feedback 1 reading while wiggling the harness at negative feedback pressure sensor 1; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Check the return line from the main valve for restriction
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 123-4Negative feedback 1 pressure sensor circuit voltage below normal
The MCU sees the Negative feedback 1 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It reports negative control pressure used in pump flow control. The negative control signal tells the pump regulator how much flow to give, so a wrong value can leave a pump stuck at minimum flow with sluggish speed or at full flow with heavy fuel burn. Look for a reading that never changes when the levers move, since a live negative control signal normally rises when levers return to neutral and drops as spools open. Also confirm the control line is free of restriction by checking its tube and filter. A clogged centre bypass tube, contaminated pilot oil or a stuck regulator spool commonly sits behind implausible control numbers. Inspect the regulator control ports for varnish and metal flakes.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near negative feedback pressure sensor 1
- negative feedback pressure sensor 1 shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug negative feedback pressure sensor 1 and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the negative feedback pressure sensor 1 connector with key on and compare it with a neighbouring sensor on the same supply
- 3Check the return line from the main valve for restriction
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 124-0Negative feedback 2 pressure sensor data above normal range
The MCU reads the Negative feedback 2 pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It reports negative control pressure for the second pump. This is the matching signal for the second pump, so the symptoms mirror sensor 1 but affect only the circuits fed by the second pump, and a difference between the two readings at neutral is the giveaway. Compare it with its twin at neutral and while moving one lever, because the two negative control readings should behave alike when both main valve banks are idle. Also confirm the second control line is free of restriction. Mirror the investigation on the sibling circuit: sludge in the bypass, a worn orifice or a seized regulator spool. Inspect the second regulator control port for varnish and flakes.· Real conditionReal conditionCheck soonCauses
- Real negative control pressure high on pump 2: restricted return
- Open signal or ground wire at the negative feedback pressure sensor 2 connector
- negative feedback pressure sensor 2 failed and reading high
Checks
- 1Read the Negative feedback 2 value on the cluster and compare it with a test gauge on the negative feedback line of pump 2 before blaming the sensor
- 2Unplug negative feedback pressure sensor 2 and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Compare feedback sensor 2 with sensor 1 with all levers neutral
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Hyundai 124-1Negative feedback 2 pressure sensor data below normal range
The MCU reads the Negative feedback 2 pressure sensor below its normal range, so the pressure it expects on the negative feedback line of pump 2 is not showing up in the signal. It reports negative control pressure for the second pump. This is the matching signal for the second pump, so the symptoms mirror sensor 1 but affect only the circuits fed by the second pump, and a difference between the two readings at neutral is the giveaway. Compare it with its twin at neutral and while moving one lever, because the two negative control readings should behave alike when both main valve banks are idle. Also confirm the second control line is free of restriction. Mirror the investigation on the sibling circuit: sludge in the bypass, a worn orifice or a seized regulator spool. Inspect the second regulator control port for varnish and flakes.· Real conditionReal conditionCheck soonCauses
- Low real pressure on the negative feedback line of pump 2: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at negative feedback pressure sensor 2
- negative feedback pressure sensor 2 drifted or failed low
Checks
- 1Compare the cluster Negative feedback 2 reading with a mechanical gauge on the negative feedback line of pump 2; if the gauge is good the sensor or wiring is at fault
- 2Check the negative feedback pressure sensor 2 connector for water or green corrosion that adds resistance to the signal
- 3Compare feedback sensor 2 with sensor 1 with all levers neutral
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Hyundai 124-2Negative feedback 2 pressure sensor data error
The MCU decides the Negative feedback 2 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It reports negative control pressure for the second pump. This is the matching signal for the second pump, so the symptoms mirror sensor 1 but affect only the circuits fed by the second pump, and a difference between the two readings at neutral is the giveaway. Compare it with its twin at neutral and while moving one lever, because the two negative control readings should behave alike when both main valve banks are idle. Also confirm the second control line is free of restriction. Mirror the investigation on the sibling circuit: sludge in the bypass, a worn orifice or a seized regulator spool. Inspect the second regulator control port for varnish and flakes.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Intermittent contact in the negative feedback pressure sensor 2 connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- negative feedback pressure sensor 2 failing intermittently
Checks
- 1Watch the Negative feedback 2 reading while wiggling the harness at negative feedback pressure sensor 2; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Compare feedback sensor 2 with sensor 1 with all levers neutral
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Hyundai 124-4Negative feedback 2 pressure sensor circuit voltage below normal
The MCU sees the Negative feedback 2 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It reports negative control pressure for the second pump. This is the matching signal for the second pump, so the symptoms mirror sensor 1 but affect only the circuits fed by the second pump, and a difference between the two readings at neutral is the giveaway. Compare it with its twin at neutral and while moving one lever, because the two negative control readings should behave alike when both main valve banks are idle. Also confirm the second control line is free of restriction. Mirror the investigation on the sibling circuit: sludge in the bypass, a worn orifice or a seized regulator spool. Inspect the second regulator control port for varnish and flakes.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near negative feedback pressure sensor 2
- negative feedback pressure sensor 2 shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug negative feedback pressure sensor 2 and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the negative feedback pressure sensor 2 connector with key on and compare it with a neighbouring sensor on the same supply
- 3Compare feedback sensor 2 with sensor 1 with all levers neutral
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Hyundai 125-0Pilot pump P3 pressure sensor data above normal range
The MCU reads the Pilot pump P3 pressure sensor above its normal range, or the signal is floating open so the reading pegs high. It reports the pilot circuit supply pressure. Pilot supply feeds every lever and travel pedal, so a wrong value can make all controls feel dead or spongy together, which separates it from a fault in a single function. Watch it with the engine at working speed and then at idle, because pilot pressure should be steady and only dip noticeably when several pilot functions draw at once. Also check the pilot filter for blockage, which lowers pilot supply. Worn gear pump, collapsed suction hose, dirty strainer or an aerated tank can starve pilot supply and show a low figure. Inspect the pilot relief valve seat for scoring and wear.· Lost messageLost messageCheck soonCauses
- Real pilot pressure high: pilot relief stuck closed
- Open signal or ground wire at the the P3 pilot pump pressure sensor connector
- the P3 pilot pump pressure sensor failed and reading high
Checks
- 1Read the Pilot pump P3 value on the cluster and compare it with a test gauge on the pilot supply line before blaming the sensor
- 2Unplug the P3 pilot pump pressure sensor and inspect the connector and the wire run for a break; an open line makes the reading rail high
- 3Check pilot pressure with a gauge at the pilot test port with the engine at working speed
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 125-1Pilot pump P3 pressure sensor data below normal range
The MCU reads the Pilot pump P3 pressure sensor below its normal range, so the pressure it expects on the pilot supply line is not showing up in the signal. It reports the pilot circuit supply pressure. Pilot supply feeds every lever and travel pedal, so a wrong value can make all controls feel dead or spongy together, which separates it from a fault in a single function. Watch it with the engine at working speed and then at idle, because pilot pressure should be steady and only dip noticeably when several pilot functions draw at once. Also check the pilot filter for blockage, which lowers pilot supply. Worn gear pump, collapsed suction hose, dirty strainer or an aerated tank can starve pilot supply and show a low figure. Inspect the pilot relief valve seat for scoring and wear.· Lost messageLost messageCheck soonCauses
- Low real pressure on the pilot supply line: weak pump, internal leak or a stuck-open relief
- Partly shorted or high-resistance signal wire at the P3 pilot pump pressure sensor
- the P3 pilot pump pressure sensor drifted or failed low
Checks
- 1Compare the cluster Pilot pump P3 reading with a mechanical gauge on the pilot supply line; if the gauge is good the sensor or wiring is at fault
- 2Check the the P3 pilot pump pressure sensor connector for water or green corrosion that adds resistance to the signal
- 3Check pilot pressure with a gauge at the pilot test port with the engine at working speed
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 125-2Pilot pump P3 pressure sensor data error
The MCU decides the Pilot pump P3 pressure sensor signal is not plausible, for example jumping or disagreeing with the rest of the system. It reports the pilot circuit supply pressure. Pilot supply feeds every lever and travel pedal, so a wrong value can make all controls feel dead or spongy together, which separates it from a fault in a single function. Watch it with the engine at working speed and then at idle, because pilot pressure should be steady and only dip noticeably when several pilot functions draw at once. Also check the pilot filter for blockage, which lowers pilot supply. Worn gear pump, collapsed suction hose, dirty strainer or an aerated tank can starve pilot supply and show a low figure. Inspect the pilot relief valve seat for scoring and wear.· Lost messageLost messageCheck soonCauses
- Intermittent contact in the the P3 pilot pump pressure sensor connector or harness
- Electrical noise or a weak chassis ground on the sensor supply
- the P3 pilot pump pressure sensor failing intermittently
Checks
- 1Watch the Pilot pump P3 reading while wiggling the harness at the P3 pilot pump pressure sensor; a jump when you move it means a connection fault
- 2Check the sensor ground and 5 V supply for steady values with the engine running and under load
- 3Check pilot pressure with a gauge at the pilot test port with the engine at working speed
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Hyundai 125-4Pilot pump P3 pressure sensor circuit voltage below normal
The MCU sees the Pilot pump P3 pressure sensor circuit pulled low, which it reads as a short to ground or a lost supply to the sensor. It reports the pilot circuit supply pressure. Pilot supply feeds every lever and travel pedal, so a wrong value can make all controls feel dead or spongy together, which separates it from a fault in a single function. Watch it with the engine at working speed and then at idle, because pilot pressure should be steady and only dip noticeably when several pilot functions draw at once. Also check the pilot filter for blockage, which lowers pilot supply. Worn gear pump, collapsed suction hose, dirty strainer or an aerated tank can starve pilot supply and show a low figure. Inspect the pilot relief valve seat for scoring and wear.· Shorted lowShorted lowCheck soonCauses
- Signal wire rubbed through to ground near the P3 pilot pump pressure sensor
- the P3 pilot pump pressure sensor shorted internally
- Sensor 5 V supply lost or pulled down by another shorted sensor on the same reference
Checks
- 1Unplug the P3 pilot pump pressure sensor and see whether the code changes from circuit low to an open-type code; if so the sensor was pulling the line down
- 2Measure the 5 V reference at the the P3 pilot pump pressure sensor connector with key on and compare it with a neighbouring sensor on the same supply
- 3Check pilot pressure with a gauge at the pilot test port with the engine at working speed
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Compare the cluster reading with a test gauge on the matching pressure port before replacing a sensor
- 2Check each sensor connector at the pump and valve bank for water and pushed-back pins
- 3Inspect the harness for chafing where it passes the pumps and valve bank
- 4Measure the sensor 5 V supply and ground at the plug with key on
- 5Compare with another sensor of the same type on the machine to confirm the fault is local
Causes
- Sensor connector corroded or loose at the pump or valve bank
- Hydraulic return restriction or relief fault on the pump circuit
- Harness chafed near the pump or control valve
- Failed sensor
Most codes here: lost message (15 of 24)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: The machine may feel slow or weak, pump control may be erratic, or an HCESPN number from 120 to 125 shows with an FMI of 0, 1, 2 or 4.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.