Hyundai · Machine codes (MCU, HCESPN)
Hyundai Fault Code 301‑3
Fuel level sensor circuit voltage above normal
What does Hyundai code 301-3 mean?
The MCU sees the fuel level sender signal above its normal window, which it reads as a short to a high source or an open wire. Urgency: check soon - the machine may derate or limit a function. Check first: dip the tank or look at the level and compare it with the gauge to confirm the gauge is wrong.
- 301
- Which machine signal is at fault
- FMI 3
- Voltage above normal or shorted high
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Dip the tank or look at the level and compare it with the gauge to confirm the gauge is wrong
Then 4 more checksWhere this code shows
Turn the key on and open the fault code or diagnosis menu on the cluster.
Checks
0 of 5 done
Causes
- Fuel sender unplugged or connector corroded at the tank
- Signal wire open or shorted to supply
- Sender float arm or resistor failed
How it failed
You'll notice: The fuel gauge reads full or empty and the low fuel warning may not work.
Shorted highRead from how the source describes the code
The signal sits at or near the supply voltage - more than a working sensor can send.
- Meter test
- Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
- Good result
- Open circuit (OL) between them. Any low reading is the short.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Fuel level, engine speed and starting aid circuits
- 301-3Fuel level sensor circuit voltage above normalShorted highCheck soon
- 301-4Fuel level sensor circuit voltage below normalShorted lowCheck soon
- 310-8Engine speed signal error, abnormal frequency or pulse widthErratic or implausibleCheck soon
- 322-4Engine preheat relay circuit voltage below normal, shorted to low source or openShorted lowCheck soon
- 322-6Engine preheat relay circuit current above normalShorted lowCheck soon
- 325-4Fuel warmer relay circuit voltage below normal, shorted to low source or openShorted lowCheck soon
- 325-6Fuel warmer relay circuit current above normalShorted lowCheck soon
- 327-4Anti-restart relay circuit voltage below normal, shorted to low source or openShorted lowCheck soon
- 327-6Anti-restart relay circuit current above normalShorted lowCheck soon
Other Hyundai codes: Machine codes (MCU, HCESPN)
Related on Equipments Finder
Source
This source lists 301-3 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Hyundai HL757-9 wheel loader (manual covers the MCU machine table and the TCU transmission table).
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.