Genie · Platform load sense faults (S-60 HC)

Genie Load sense boom position sensors (string potentiometer and boom angle sensor) fault codes

The string potentiometer measures boom length for the load sense system. Error source 21 is the operational sensor and error source 22 the safety sensor; the safety sensor also has a cross check.

More about these parts

The boom angle sensor reports boom angle to the load sense controllers. Error source 31 is the operational sensor and error source 32 the safety sensor.

FaultStopLS 21-5Genie · Load sense boom position sensors (string potentiometer and boom angle sensor)
Code shows hereFAULTLS 21-5

Where this code shows

Scissors: read the code on the platform LED display or the ground control LCD.

What do these codes mean?

Genie codes LS 21-5 to LS 32-21 are all about the load sense boom position sensors (string potentiometer and boom angle sensor). The most common failure type is real condition (8 of 30); 22 need an immediate stop. Start with this check: check the sensor wiring and connector for damage and corrosion.

How urgent are they?

22 of 30 codes here mean stop now; 8 are information only.

  • Stop now22
  • Info8

What should I check first?

Check the sensor wiring and connector for damage and corrosion.

Shared checks

30 of 30

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Genie LS 21-5String potentiometer (operational): sensor tolerance fault

    String potentiometer (operational): The reading is outside the sensor tolerance band without being a clean short or open.· Other
    Stop now

    Causes

    • String potentiometer (operational): sensor drifted, damaged or mechanically misaligned, so it still reports but outside tolerance
    • Wiring or connector fault on this channel

    Checks

    1. 1Compare the live reading with the real position of the boom (angle, length or platform load); a steady offset points at the sensor or its mounting, a reading that jumps when the harness is moved points at the connector.
    2. 2Inspect the string potentiometer for proper operation and connection to the boom, and check that its cable runs freely and is not kinked.
    3. 3Cycle the key switch after the repair and confirm the code does not return; the safety channel of the same sensor is cross-checked against this one, so a repair here can also clear its twin code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 21-11String potentiometer (operational): output short high

    String potentiometer (operational): The sensor output is stuck at the top of its range, as if shorted high.· Shorted high
    Stop now

    Causes

    • String potentiometer (operational): signal wire shorted to the sensor supply
    • Wiring or connector fault on this channel

    Checks

    1. 1Unplug the sensor and read its signal pin with the key on; supply voltage there means the harness is shorted high, while a normal reading means the sensor itself is pinned.
    2. 2Inspect the string potentiometer for proper operation and connection to the boom, and check that its cable runs freely and is not kinked.
    3. 3Cycle the key switch after the repair and confirm the code does not return; the safety channel of the same sensor is cross-checked against this one, so a repair here can also clear its twin code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Genie LS 21-12String potentiometer (operational): value too high

    Same failure as LS 21-11 (signal high), here on the string potentiometer (operational): value too high.· Real condition
    Stop now

    Causes

    • String potentiometer (operational): open sensor ground or a partly shorted signal wire letting the value float up
    • Wiring or connector fault on this channel

    Checks

    1. 1Read the value across the working range; a value that is high everywhere but still moves points at an open ground or a worn sensor rather than a hard short.
    2. 2Inspect the string potentiometer for proper operation and connection to the boom, and check that its cable runs freely and is not kinked.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie LS 21-15String potentiometer (operational): value too low

    String potentiometer (operational): The sensor value is below the allowed window but not necessarily at zero.· Real condition
    Stop now

    Causes

    • String potentiometer (operational): weak or high-resistance sensor supply, or a partly grounded signal wire
    • Wiring or connector fault on this channel

    Checks

    1. 1Check the sensor supply voltage at the plug first, since a low supply drags the whole reading down.
    2. 2Inspect the string potentiometer for proper operation and connection to the boom, and check that its cable runs freely and is not kinked.
    3. 3Cycle the key switch after the repair and confirm the code does not return; the safety channel of the same sensor is cross-checked against this one, so a repair here can also clear its twin code.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie LS 21-16String potentiometer (operational): output short low

    Same failure as LS 21-15 (signal low), here on the string potentiometer (operational): output short low.· Shorted low
    Stop now

    Causes

    • String potentiometer (operational): signal wire shorted to ground or the sensor supply lost
    • Wiring or connector fault on this channel

    Checks

    1. 1Check the signal wire for continuity to ground with the sensor unplugged; an open and a short to ground both read low but need different repairs.
    2. 2Inspect the string potentiometer for proper operation and connection to the boom, and check that its cable runs freely and is not kinked.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Genie LS 21-17String potentiometer (operational): not calibrated

    String potentiometer (operational): The sensor has no calibration stored, so the boom range of motion is limited.· Part or controller
    Info

    Causes

    • String potentiometer (operational): sensor replaced or calibration lost after a reset
    • Controller reprogrammed or the sensor plug reseated during the repair

    Checks

    1. 1Run the platform load sense calibration for this sensor through its full range, then confirm the code is gone.
    2. 2Inspect the string potentiometer for proper operation and connection to the boom, and check that its cable runs freely and is not kinked.
    3. 3Cycle the key switch after the repair and confirm the code does not return; the safety channel of the same sensor is cross-checked against this one, so a repair here can also clear its twin code.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Genie LS 21-18String potentiometer (operational): just calibrated

    String potentiometer (operational): The sensor was just calibrated; this status is used to clear diagnostic codes and clears itself.· Other
    Info

    Causes

    • String potentiometer (operational): calibration just completed
    • Status reported once after the calibration routine and cleared on the next power cycle

    Checks

    1. 1This status needs no repair: cycle the power and confirm it does not return.
    2. 2Inspect the string potentiometer for proper operation and connection to the boom, and check that its cable runs freely and is not kinked.
    3. 3Cycle the key switch after the repair and confirm the code does not return; the safety channel of the same sensor is cross-checked against this one, so a repair here can also clear its twin code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 22-5String potentiometer (safety): sensor tolerance fault

    Same fault as LS 21-5, on the safety string potentiometer channel; read both channels.· Other
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 22-11String potentiometer (safety): output short high

    Same fault as LS 21-11, on the safety string potentiometer channel; read both channels.· Other
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 22-12String potentiometer (safety): value too high

    Same fault as LS 21-12, on the safety string potentiometer channel; read both channels.· Real condition
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie LS 22-15String potentiometer (safety): value too low

    Same fault as LS 21-15, on the safety string potentiometer channel; read both channels.· Real condition
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie LS 22-16String potentiometer (safety): output short low

    Same fault as LS 21-16, on the safety string potentiometer channel; read both channels.· Other
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 22-17String potentiometer (safety): not calibrated

    Same fault as LS 21-17, on the safety string potentiometer channel; read both channels.· Other
    Info

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 22-18String potentiometer (safety): just calibrated

    Same fault as LS 21-18, on the safety string potentiometer channel; read both channels.· Other
    Info

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 22-21String potentiometer (safety): inconsistent

    Same fault as LS 21-21, on the safety string potentiometer channel; read both channels.· Other
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 31-5Boom angle sensor (operational): sensor tolerance fault

    Same failure as LS 21-5 (out of range), here on the boom angle sensor (operational): sensor tolerance.· Other
    Stop now

    Causes

    • Boom angle sensor (operational): sensor drifted, damaged or mechanically misaligned, so it still reports but outside tolerance
    • Wiring or connector fault on this channel

    Checks

    1. 1Compare the live reading with the real position of the boom (angle, length or platform load); a steady offset points at the sensor or its mounting, a reading that jumps when the harness is moved points at the connector.
    2. 2Inspect the boom angle sensor and its mounting for a loose or knocked bracket, which shifts the reading without any wiring fault.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 31-11Boom angle sensor (operational): output short high

    Same failure as LS 21-11 (signal high), here on the boom angle sensor (operational): output short high.· Shorted high
    Stop now

    Causes

    • Boom angle sensor (operational): signal wire shorted to the sensor supply
    • Wiring or connector fault on this channel

    Checks

    1. 1Unplug the sensor and read its signal pin with the key on; supply voltage there means the harness is shorted high, while a normal reading means the sensor itself is pinned.
    2. 2Inspect the boom angle sensor and its mounting for a loose or knocked bracket, which shifts the reading without any wiring fault.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Genie LS 31-12Boom angle sensor (operational): value too high

    Same failure as LS 21-11 (signal high), here on the boom angle sensor (operational): value too high.· Real condition
    Stop now

    Causes

    • Boom angle sensor (operational): open sensor ground or a partly shorted signal wire letting the value float up
    • Wiring or connector fault on this channel

    Checks

    1. 1Read the value across the working range; a value that is high everywhere but still moves points at an open ground or a worn sensor rather than a hard short.
    2. 2Inspect the boom angle sensor and its mounting for a loose or knocked bracket, which shifts the reading without any wiring fault.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie LS 31-15Boom angle sensor (operational): value too low

    Same failure as LS 21-15 (signal low), here on the boom angle sensor (operational): value too low.· Real condition
    Stop now

    Causes

    • Boom angle sensor (operational): weak or high-resistance sensor supply, or a partly grounded signal wire
    • Wiring or connector fault on this channel

    Checks

    1. 1Check the sensor supply voltage at the plug first, since a low supply drags the whole reading down.
    2. 2Inspect the boom angle sensor and its mounting for a loose or knocked bracket, which shifts the reading without any wiring fault.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie LS 31-16Boom angle sensor (operational): output short low

    Same failure as LS 21-15 (signal low), here on the boom angle sensor (operational): output short low.· Shorted low
    Stop now

    Causes

    • Boom angle sensor (operational): signal wire shorted to ground or the sensor supply lost
    • Wiring or connector fault on this channel

    Checks

    1. 1Check the signal wire for continuity to ground with the sensor unplugged; an open and a short to ground both read low but need different repairs.
    2. 2Inspect the boom angle sensor and its mounting for a loose or knocked bracket, which shifts the reading without any wiring fault.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Genie LS 31-17Boom angle sensor (operational): not calibrated

    Boom angle sensor (operational): The sensor has no calibration stored, so the boom range of motion is limited.· Part or controller
    Info

    Causes

    • Boom angle sensor (operational): sensor replaced or calibration lost after a reset
    • Controller reprogrammed or the sensor plug reseated during the repair

    Checks

    1. 1Run the platform load sense calibration for this sensor through its full range, then confirm the code is gone.
    2. 2Inspect the boom angle sensor and its mounting for a loose or knocked bracket, which shifts the reading without any wiring fault.
    3. 3Cycle the key switch after the repair and confirm the code does not return; the safety channel of the same sensor is cross-checked against this one, so a repair here can also clear its twin code.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Genie LS 31-18Boom angle sensor (operational): just calibrated

    Boom angle sensor (operational): The sensor was just calibrated; this status is used to clear diagnostic codes and clears itself.· Other
    Info

    Causes

    • Boom angle sensor (operational): calibration just completed
    • Status reported once after the calibration routine and cleared on the next power cycle

    Checks

    1. 1This status needs no repair: cycle the power and confirm it does not return.
    2. 2Inspect the boom angle sensor and its mounting for a loose or knocked bracket, which shifts the reading without any wiring fault.
    3. 3Cycle the key switch after the repair and confirm the code does not return; the safety channel of the same sensor is cross-checked against this one, so a repair here can also clear its twin code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 32-5Boom angle sensor (safety): sensor tolerance fault

    Same fault as LS 31-5, on the safety boom angle sensor channel; read both channels.· Other
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 32-11Boom angle sensor (safety): output short high

    Same fault as LS 31-11, on the safety boom angle sensor channel; read both channels.· Other
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 32-12Boom angle sensor (safety): value too high

    Same fault as LS 31-12, on the safety boom angle sensor channel; read both channels.· Real condition
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie LS 32-15Boom angle sensor (safety): value too low

    Same fault as LS 31-15, on the safety boom angle sensor channel; read both channels.· Real condition
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Genie LS 32-16Boom angle sensor (safety): output short low

    Same fault as LS 31-16, on the safety boom angle sensor channel; read both channels.· Other
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 32-17Boom angle sensor (safety): not calibrated

    Same fault as LS 31-17, on the safety boom angle sensor channel; read both channels.· Other
    Info

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 32-18Boom angle sensor (safety): just calibrated

    Same fault as LS 31-18, on the safety boom angle sensor channel; read both channels.· Other
    Info

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Genie LS 32-21Boom angle sensor (safety): inconsistent

    Same fault as LS 31-21, on the safety boom angle sensor channel; read both channels.· Other
    Stop now

    Causes

    • Safety channel wiring or connector fault
    • Safety sensor element drifted or damaged

    Checks

    1. 1Read both channels together.
    2. 2Repair the safety wiring, then cycle power.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Check the sensor wiring and connector for damage and corrosion.
  2. 2Inspect the string potentiometer or boom angle sensor and its mounting to the boom for proper operation.
  3. 3Repair the wiring and connections of the named sensor and channel.
  4. 4Replace the sensor and calibrate the overload system if the fault persists.
  5. 5Calibrate the platform load sense system after any replacement.

Causes

  • String potentiometer wiring open or shorted (load sense string potentiometer)
  • Sensor failed or out of tolerance
  • Sensor not calibrated (load sense string potentiometer)
  • Operational and safety sensor disagree

Most common here: real condition (8 of 30)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: Power relays disengage and boom range of motion may be limited until the potentiometer is repaired or calibrated.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.