EF Logo

Genie · Control system fault codes (ALC-500 red/yellow LED)

Genie Fault Code 24‑17

Angle sensor not calibrated

What does Genie code 24-17 mean?

The boom angle sensor is not calibrated and boom speed is reduced. It usually follows a sensor or controller replacement. Urgency: check soon - the machine may derate or limit a function. Check first: run the boom angle sensor calibration from the service menu with the boom in the position the procedure calls for.

FaultCheck24-17Genie · Control system fault codes (ALC-500 red/yellow LED)

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Run the boom angle sensor calibration from the service menu with the boom in the position the procedure calls for.

Then 3 more checks
Code shows hereFAULT24-17

Where this code shows

Scissors: read the code on the platform LED display or the ground control LCD.

Checks

0 of 4 done

Causes

  • Angle sensor replaced without calibration
  • Controller reset or software updated
  • Calibration data lost
  • Sensor mounting moved

How it failed

You'll notice: Boom speed is reduced because the boom angle sensor has no calibration.

OtherRead from how the source describes the code

The source does not say how this one failed.

Meter test
Read the code with the service tool and note which other codes are active with it.
Good result
Codes that appear together usually share one cause - start with the wiring they share.

When to stop

Lower attachments to the ground and relieve hydraulic pressure before loosening any fitting. Never feel for a leak with your hand - oil under pressure can inject through skin.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Same part, other failures: ALC-500 boom angle, load cell, limit switches and overload relays

Show the other 16 codes
All 25 ALC-500 boom angle, load cell, limit switches and overload relays codes on one page

Source

Genie S-60/S-65 Service and Repair Manual 1268492, Control System Fault Codes

This source lists 24-17 and its meaning. The guidance on this page is general, not taken from it.

The source covers: Genie S-60, S-65, S-60 TRAX, S-65 TRAX, S-60 HC, S-60X/XC with ALC-500 controller.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.