Detroit · Electrical
Detroit Sensor supply voltages fault codes
The MCM provides 5 V and 3 V supplies to its sensors on several banks. A short on one sensor pulls the whole bank down.
Where to read it
Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.
What do these codes mean?
Detroit codes SPN 3509 FMI 0 to SPN 3511 FMI 4 are all about the sensor supply voltages. The most common failure type is shorted high (3 of 8); none needs an immediate stop. Start with this check: unplug the sensors on the affected bank one at a time and see which one restores the supply.
How urgent are they?
None of the 8 codes here means stop now; all 8 can wait until the shift ends, but find the cause before the next one.
- Check soon8
What should I check first?
Unplug the sensors on the affected bank one at a time and see which one restores the supply.
Shared checks8 of 8
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Detroit SPN 3509 FMI 0Coolant Level Sensor Circuit Failed High
Detroit lists SPN 3509 FMI 0 as "Coolant Level Sensor Circuit Failed High". The MCM reports that the measured value itself is out of its normal range; the sensor supply may be correct and a real condition may exist. This 5 V supply feeds a group of sensors, such as the coolant level sensor; if one sensor shorts, the supply drops for all of them.· Real conditionReal conditionCheck soonCauses
- A real fault in the system the sensor supply measures
- Sensor reading skewed by a wiring or connector problem
Checks
- 1Confirm the real value with a mechanical gauge or an independent reading before replacing the sensor supply.
- 2Check the system for the condition the code describes and fix it first.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 3509 FMI 1Coolant Level Sensor Supply X3_01 - Circuit Failed Low
Detroit lists SPN 3509 FMI 1 as "Coolant Level Sensor Supply X3_01 - Circuit Failed Low". The MCM reports that the measured value itself is out of its normal range; the sensor supply may be correct and a real condition may exist. This 5 V supply feeds a group of sensors, such as the coolant level sensor; if one sensor shorts, the supply drops for all of them.· Real conditionReal conditionCheck soonCauses
- A real fault in the system the sensor supply measures
- Sensor reading skewed by a wiring or connector problem
Checks
- 1Confirm the real value with a mechanical gauge or an independent reading before replacing the sensor supply.
- 2Check the system for the condition the code describes and fix it first.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Detroit SPN 3509 FMI 3The 5V Sensor Supply Bank 1 Circuit Failed High
Same failure as SPN 3509 FMI 0 ("Coolant Level Sensor Circuit Failed High") on a sibling part: Detroit lists SPN 3509 FMI 3 as "The 5V Sensor Supply Bank 1 Circuit Failed High". This 5 V supply feeds a group of sensors, such as the coolant level sensor; if one sensor shorts, the supply drops for all of them.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3509 FMI 0, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3509 FMI 0, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3509 FMI 45V Sensor Supply Bank 1 Circuit Failed Low
Same failure as SPN 3509 FMI 1 ("Coolant Level Sensor Supply X3_01 - Circuit Failed Low") on a sibling part: Detroit lists SPN 3509 FMI 4 as "5V Sensor Supply Bank 1 Circuit Failed Low". This 5 V supply feeds a group of sensors, such as the coolant level sensor; if one sensor shorts, the supply drops for all of them.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3509 FMI 1, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3509 FMI 1, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3510 FMI 3Aftertreatment Control Module 2 Sensor Supply 2 Short to Battery
Same failure as SPN 3509 FMI 0 ("Coolant Level Sensor Circuit Failed High") on a sibling part: Detroit lists SPN 3510 FMI 3 as "Aftertreatment Control Module 2 Sensor Supply 2 Short to Battery". This is the second 5 V supply bank of the MCM; a short on any sensor on it pulls the whole bank down.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3509 FMI 0, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3509 FMI 0, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3510 FMI 45V Sensor Supply Bank 2 Circuit Failed Low
Same failure as SPN 3509 FMI 1 ("Coolant Level Sensor Supply X3_01 - Circuit Failed Low") on a sibling part: Detroit lists SPN 3510 FMI 4 as "5V Sensor Supply Bank 2 Circuit Failed Low". This is the second 5 V supply bank of the MCM; a short on any sensor on it pulls the whole bank down.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3509 FMI 1, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3509 FMI 1, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Detroit SPN 3511 FMI 33V Sensor Supply Bank 1 Circuit Failed High
Same failure as SPN 3509 FMI 0 ("Coolant Level Sensor Circuit Failed High") on a sibling part: Detroit lists SPN 3511 FMI 3 as "3V Sensor Supply Bank 1 Circuit Failed High". The 3 V supply feeds the low-voltage sensors on bank 1; a short here usually points to a connector or harness fault.· Shorted highShorted highCheck soonCauses
- The causes listed under SPN 3509 FMI 0, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3509 FMI 0, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Detroit SPN 3511 FMI 43V Sensor Supply Bank 1 Circuit Failed Low
Same failure as SPN 3509 FMI 1 ("Coolant Level Sensor Supply X3_01 - Circuit Failed Low") on a sibling part: Detroit lists SPN 3511 FMI 4 as "3V Sensor Supply Bank 1 Circuit Failed Low". The 3 V supply feeds the low-voltage sensors on bank 1; a short here usually points to a connector or harness fault.· Shorted lowShorted lowCheck soonCauses
- The causes listed under SPN 3509 FMI 1, found on this part and its own connector and harness leg
- A fault that affects only this channel and not the part that the first code names
Checks
- 1Run the checks listed under SPN 3509 FMI 1, but at this part and on its own wires.
- 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Shared checks
Checks, in order
- 1Unplug the sensors on the affected bank one at a time and see which one restores the supply.
- 2Check the supply wire for a short to ground along the harness.
- 3Inspect the sensor connectors for water and corrosion.
- 4Replace the MCM only after every sensor and the harness have been ruled out.
Causes
- A shorted sensor on the same supply
- Harness damage
- MCM supply fault
- Water in a connector
Most common here: shorted high (3 of 8)
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
When to stop
You'll notice: Several sensor codes at the same time on one bank of sensors, and a possible derate.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
- Detroit Diesel DD15 Gen 5 (2023) Fault Codes List, Diesel Repair (SPN/FMI with Detroit descriptions)
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.