EF Logo

Detroit · Controller faults

Detroit ACM internal faults and proportional valves fault codes

The Aftertreatment Control Module has internal checks, communication with its chips and proportional valve outputs. Detroit logs these as internal errors.

FaultCheckSPN 3597FMI 3Detroit · ACM internal faults and proportional valves
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a Detroit-capable diagnostic tool (Diagnostic Link or a compatible scan tool) to the vehicle diagnostic socket.

What do these codes mean?

Detroit codes SPN 3597 FMI 3 to SPN 520395 FMI 13 are all about the aCM internal faults and proportional valves. The most common failure type is part or controller (5 of 18); none needs an immediate stop. Start with this check: check the ACM supply and ground and look for a voltage drop under load.

How urgent are they?

None of the 18 codes here means stop now; all 18 can wait until the shift ends, but find the cause before the next one.

  • Check soon18

What should I check first?

Check the ACM supply and ground and look for a voltage drop under load.

Shared checks

18 of 18

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Detroit SPN 3597 FMI 3Proportional Valve Bank 1 Circuit Failed High

    Detroit lists SPN 3597 FMI 3 as "Proportional Valve Bank 1 Circuit Failed High".· Shorted high
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3Proportional valve bank 1 is shorted high; check the valve wiring for a short to supply.
    4. 4Bank 1 valve shorted high: check the valve wires for a short to supply.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 3597 FMI 4High Side Digital Output 1 Circuit Failed Low

    Detroit lists SPN 3597 FMI 4 as "High Side Digital Output 1 Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3High side digital output 1 is shorted low; check the output wiring for a short to ground.
    4. 4High side output 1 shorted low: check the output wire for a short to ground.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 3597 FMI 6Proportional Valve Bank 1 Circuit Failed Low

    Same failure as SPN 3597 FMI 4 ("High Side Digital Output 1 Circuit Failed Low") on a sibling part: Detroit lists SPN 3597 FMI 6 as "Proportional Valve Bank 1 Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • The causes listed under SPN 3597 FMI 4, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3597 FMI 4, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 3598 FMI 3Proportional Valve Bank 2 Circuit Failed High

    Same failure as SPN 3597 FMI 3 ("Proportional Valve Bank 1 Circuit Failed High") on a sibling part: Detroit lists SPN 3598 FMI 3 as "Proportional Valve Bank 2 Circuit Failed High".· Shorted high
    Check soon

    Causes

    • The causes listed under SPN 3597 FMI 3, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3597 FMI 3, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Detroit SPN 3598 FMI 4Proportional Valve Bank 2 Circuit Failed Low

    Same failure as SPN 3597 FMI 4 ("High Side Digital Output 1 Circuit Failed Low") on a sibling part: Detroit lists SPN 3598 FMI 4 as "Proportional Valve Bank 2 Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • The causes listed under SPN 3597 FMI 4, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3597 FMI 4, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 3598 FMI 6Proportional Valve Bank 2 Circuit Failed Low

    Same failure as SPN 3597 FMI 4 ("High Side Digital Output 1 Circuit Failed Low") on a sibling part: Detroit lists SPN 3598 FMI 6 as "Proportional Valve Bank 2 Circuit Failed Low".· Shorted low
    Check soon

    Causes

    • The causes listed under SPN 3597 FMI 4, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 3597 FMI 4, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Detroit SPN 520241 FMI 14ADC Check

    Detroit lists SPN 520241 FMI 14 as "ADC Check".· Other
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3The ADC check failed in the ACM; check the supply and replace the ACM if the code persists.
    4. 4ADC check failure in the ACM: check supply, then replace the ACM if it persists.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Detroit SPN 520242 FMI 11ACM Functional Safety Disabled Through Reprogramming

    Detroit lists SPN 520242 FMI 11 as "ACM Functional Safety Disabled Through Reprogramming".· Other
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3ACM functional safety is disabled by reprogramming; reflash the ACM with the correct software.
    4. 4Functional safety disabled by reprogramming: reflash the ACM correctly.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Detroit SPN 520242 FMI 31Black Channel Communication Interrupted

    Detroit lists SPN 520242 FMI 31 as "Black Channel Communication Interrupted".· Real condition
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3The black channel communication was interrupted; check the CAN link between the ACM and the safety partner.
    4. 4Black channel interrupted: check the CAN link to the safety partner.
    5. 5Black channel is the safety-related data path between the ACM and its partner controller; an interruption here is a bus or supply problem and not a sensor fault.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 520389 FMI 11Aftertreatment 1 ECU Internal Controller Root Cause Not Known

    Detroit lists SPN 520389 FMI 11 as "Aftertreatment 1 ECU Internal Controller Root Cause Not Known".· Part or controller
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3The ACM reports an internal fault with an unknown root cause; check the supply and software first.
    4. 4Unknown root cause: check supply and software first.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 520389 FMI 14Aftertreatment 1 ECU Internal Controller Special Instructions

    Detroit lists SPN 520389 FMI 14 as "Aftertreatment 1 ECU Internal Controller Special Instructions".· Part or controller
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3The ACM internal fault carries special instructions; read the description in the tool and follow it.
    4. 4Special instructions: read the description and follow it.
    5. 5The ACM internal special-instruction fault carries a text that must be followed exactly; do not clear it before the stated action has been completed.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 520389 FMI 31Aftertreatment 1 ECU Internal Controller Condition Exists

    Detroit lists SPN 520389 FMI 31 as "Aftertreatment 1 ECU Internal Controller Condition Exists".· Real condition
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3The ACM reports that an internal condition exists; read the other ACM codes.
    4. 4Condition exists: read the other ACM codes.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 520390 FMI 0ECU Temperature From Microcontroller ‘Die Temperature Sensor’ - Too High

    Detroit lists SPN 520390 FMI 0 as "ECU Temperature From Microcontroller ‘Die Temperature Sensor’ - Too High".· Real condition
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3The ACM chip temperature is too high; check the ACM mounting and the heat sources nearby.
    4. 4ACM chip temperature too high: check mounting and heat.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 520390 FMI 11ADC check

    Same failure as SPN 520241 FMI 14 ("ADC Check") on a sibling part: Detroit lists SPN 520390 FMI 11 as "ADC check".· Real condition
    Check soon

    Causes

    • The causes listed under SPN 520241 FMI 14, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 520241 FMI 14, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Detroit SPN 520393 FMI 13Communication error with ATIC_235

    Detroit lists SPN 520393 FMI 13 as "Communication error with ATIC_235".· Part or controller
    Check soon

    Causes

    • Low supply voltage or a bad ground
    • Software or data mismatch

    Checks

    1. 1Check the supply and the ground of the ACM.
    2. 2Check the software and parameters in the tool.
    3. 3The ACM cannot talk to its internal ATIC chip; replace the ACM if the supply is good.
    4. 4ATIC 235 communication error: replace the ACM if the supply is good.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 520394 FMI 13Communication error with LM95071

    Same failure as SPN 520393 FMI 13 ("Communication error with ATIC_235") on a sibling part: Detroit lists SPN 520394 FMI 13 as "Communication error with LM95071".· Part or controller
    Check soon

    Causes

    • The causes listed under SPN 520393 FMI 13, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 520393 FMI 13, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Detroit SPN 520395 FMI 9Communication Error With First NCV7520

    Same failure as SPN 520393 FMI 13 ("Communication error with ATIC_235") on a sibling part: Detroit lists SPN 520395 FMI 9 as "Communication Error With First NCV7520".· Lost message
    Check soon

    Causes

    • The causes listed under SPN 520393 FMI 13, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 520393 FMI 13, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Detroit SPN 520395 FMI 13Communication error with ATIC_153

    Same failure as SPN 520393 FMI 13 ("Communication error with ATIC_235") on a sibling part: Detroit lists SPN 520395 FMI 13 as "Communication error with ATIC_153".· Part or controller
    Check soon

    Causes

    • The causes listed under SPN 520393 FMI 13, found on this part and its own connector and harness leg
    • A fault that affects only this channel and not the part that the first code names

    Checks

    1. 1Run the checks listed under SPN 520393 FMI 13, but at this part and on its own wires.
    2. 2Compare it with the sibling part that has no code; a reading that differs from it marks this one as the faulty part.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

Shared checks

Checks, in order

  1. 1Check the ACM supply and ground and look for a voltage drop under load.
  2. 2Check the ACM software version against the current release.
  3. 3Inspect the ACM connectors for bent pins and moisture.
  4. 4Replace the ACM only if the faults return after the wiring and software are ruled out.

Causes

  • ACM internal fault
  • Low supply voltage
  • Software mismatch
  • Connector damage

Most common here: part or controller (5 of 18)

Check power and ground at the module connector with the key on, then its fuses.

When to stop

You'll notice: A check-engine lamp and, in some cases, a derate or shutdown of the aftertreatment functions.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.