EF Logo

Bobcat · Engine starting

Bobcat Glow plugs, starter and keyless start fault codes

These circuits get the engine turning and firing: the glow plug relay and plugs, the starter solenoid and relay, the wait-to-start lamp and the keyless entry and start module. A code names the output that is shorted, open or stuck, or the module that has lost communication.

FaultCheck22-03Bobcat · Glow plugs, starter and keyless start
Code shows hereFAULT22-03

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes VRY001-05 to M8303 are all about the glow plugs, starter and keyless start. The most common failure type is shorted low (6 of 33); none needs an immediate stop. Start with this check: load-test the battery and clean the cable ends and the engine ground strap before testing any starting circuit.

How urgent are they?

None of the 33 codes here means stop now; all 33 can wait until the shift ends, but find the cause before the next one.

  • Check soon33

What should I check first?

Load-test the battery and clean the cable ends and the engine ground strap before testing any starting circuit.

Shared checks

33 of 33

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat VRY001-05Glow plug relay, current below normal

    The controller measures less current than expected on the glow plug relay circuit.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin at the plug
    • Coil or element failed open
    • Corroded connector adding resistance

    Checks

    1. 1Unplug the glow plug relay and measure its coil resistance; open or very high means it has failed
    2. 2Check the plug pins for corrosion and push-out
    3. 3Check wire continuity from the plug to the controller
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VRY001-06Glow plug relay, current above normal

    The controller measures more current than expected on the glow plug relay circuit.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to the frame
    • Controller driver failed

    Checks

    1. 1Measure the glow plug relay coil resistance and compare with the same part on a good machine
    2. 2Test the output wire to ground with the plug off
    3. 3Inspect the harness for crush points and rubbed insulation
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VRY007-05Starter relay, current below normal

    The controller measures less current than expected on the starter relay circuit.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin at the plug
    • Coil or element failed open
    • Corroded connector adding resistance

    Checks

    1. 1Unplug the starter relay and measure its coil resistance; open or very high means it has failed
    2. 2Check the plug pins for corrosion and push-out
    3. 3Check wire continuity from the plug to the controller
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VRY007-06Starter relay, current above normal

    The controller measures more current than expected on the starter relay circuit.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to the frame
    • Controller driver failed

    Checks

    1. 1Measure the starter relay coil resistance and compare with the same part on a good machine
    2. 2Test the output wire to ground with the plug off
    3. 3Inspect the harness for crush points and rubbed insulation
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat VRY008-05Glow plug II relay, current below normal

    The controller measures less current than expected on the glow plug ii relay circuit.· Open circuit
    Check soon

    Causes

    • Broken wire or loose pin at the plug
    • Coil or element failed open
    • Corroded connector adding resistance

    Checks

    1. 1Unplug the glow plug ii relay and measure its coil resistance; open or very high means it has failed
    2. 2Check the plug pins for corrosion and push-out
    3. 3Check wire continuity from the plug to the controller
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat VRY008-06Glow plug II relay, current above normal

    The controller measures more current than expected on the glow plug ii relay circuit.· Shorted low
    Check soon

    Causes

    • Coil shorted between turns
    • Wire chafed to the frame
    • Controller driver failed

    Checks

    1. 1Measure the glow plug ii relay coil resistance and compare with the same part on a good machine
    2. 2Test the output wire to ground with the plug off
    3. 3Inspect the harness for crush points and rubbed insulation
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat 21-02Glow plug error on

    The controller sees the glow plug switched on when it was commanded off.· Shorted high
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck on
    • Controller output stage failed

    Checks

    1. 1Unplug the glow plug with the key on; if the controller still reads it on, the fault is in the wiring or controller
    2. 2Check the output wire for contact with a power wire along its run
    3. 3Listen and feel for the part energising while it should be off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat 21-03Glow plug error OFF

    The controller sees the glow plug output not energised when it has commanded it on.· Other
    Check soon

    Causes

    • Open coil
    • Blown fuse on the glow plug output feed
    • Output driver not switching

    Checks

    1. 1Check for glow plugs drawing too much current from age, which can make the coil draw wrongly
    2. 2Check the fuse that supplies the glow plug output circuit and replace it if blown, then look for the cause
    3. 3Measure the glow plug output coil resistance with the plug off; an open coil reads infinite
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 22-02Starter error ON

    The controller sees the starter output energised when it has commanded it off.· Other
    Check soon

    Causes

    • Coil or valve stuck on
    • Starter solenoid or motor drawing abnormal current
    • Controller output stuck on

    Checks

    1. 1Check for a sticking starter solenoid or a worn starter drawing too much current, which can hold the function on even with the coil off
    2. 2With the starter output unplugged and the output commanded off, check for voltage on the output pin; any voltage shows a stuck driver or a short to a live wire
    3. 3Test the starter output coil resistance with the plug off and compare it with a known good one
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 22-03Starter error OFF

    The controller sees the starter output not energised when it has commanded it on.· Other
    Check soon

    Causes

    • Starter solenoid or motor drawing abnormal current
    • Output driver not switching
    • Open coil
    • Broken wire or loose plug
    • Blown fuse on the starter output feed

    Checks

    1. 1Check for a sticking starter solenoid or a worn starter drawing too much current, which can make the coil draw wrongly
    2. 2Check the fuse that supplies the starter output circuit and replace it if blown, then look for the cause
    3. 3Measure the starter output coil resistance with the plug off; an open coil reads infinite
    4. 4Check the starter solenoid terminals and the battery cable to the starter for heat marks, loose nuts and green crust
    5. 5Check the wiring along the start circuit wire from the controller to the starter solenoid for continuity and for pins pushed back out of their housings
    6. 6With the key on and the function commanded, measure the voltage on the output wire at the plug. Then: turn the key to start with the bar down; the starter should engage on the first try and stop turning as soon as the engine fires
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat 34-04Keyless panel no communication to Bobcat controller

    The keyless panel cannot talk to the main controller.· Lost message
    Check soon

    Causes

    • Failed keyless panel
    • Loose or corroded keyless panel connector
    • Communication wire between the panel and the controller damaged

    Checks

    1. 1Check the keyless panel plug for pushed-back pins and corrosion and reseat it
    2. 2Check the communication wires between the panel and the main controller for continuity with the key off
    3. 3Check the panel supply and ground wires with the key on
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat P100A-11Starter output short to ground

    The controller reads the starter output circuit pulled to ground, so it cannot drive the load.· Shorted low
    Check soon

    Causes

    • Wire chafed against the frame or a bracket
    • Coil or element shorted to its housing
    • Water in the connector or a pin touching the shell

    Checks

    1. 1With the plug off, test the output wire to chassis ground; a reading near zero shows a harness short
    2. 2Measure from each coil pin to the body of the starter output; any continuity means the part is shorted
    3. 3Look for harness sections crushed under clamps or cut by sharp edges near the starter output
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat P100A-12Starter output short to battery

    The controller reads the starter output circuit as tied to battery voltage when it should be switched by the controller.· Shorted high
    Check soon

    Causes

    • Output wire rubbed through and touching a live supply wire
    • Water or corrosion in the plug bridging a pin to a power pin
    • Controller output stage failed shorted to supply

    Checks

    1. 1Unplug the starter output and check the output wire for voltage with the key on; any voltage with the load removed is a short to supply
    2. 2Trace the wire along the harness for chafing next to live supply wires and for melted insulation
    3. 3Replace the starter output only if the wire reads clean and the coil or element itself reads shorted
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat P100A-13Starter output open circuit

    The controller sees an open circuit on the starter output, meaning no current can flow through it.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched
    • Wire broken inside its insulation near a bend or clamp
    • Coil or element burnt open

    Checks

    1. 1Check the connector at the starter output is fully seated and its lock tab engaged
    2. 2Measure the resistance across the part with the plug off; infinite resistance confirms an open
    3. 3Check continuity of each wire from the plug back to the controller connector
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat P100B-16Starter output error off

    The controller sees the starter output off when it was commanded on.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • Coil or element failed
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the starter output circuit with the key on
    2. 2Measure the resistance of the part and look for an open or a short to its body
    3. 3Command the function and measure voltage at the plug; none means a wiring or controller fault
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Bobcat P100B-17Starter output error on

    The controller sees the starter output switched on when it was commanded off.· Shorted high
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck on
    • Controller output stage failed

    Checks

    1. 1Unplug the starter output with the key on; if the controller still reads it on, the fault is in the wiring or controller
    2. 2Check the output wire for contact with a power wire along its run
    3. 3Listen and feel for the part energising while it should be off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M2102Glow plug output error on

    The controller sees the glow plug output energised when it is commanded off.· Other
    Check soon

    Causes

    • Coil or housing stuck energised
    • Another circuit in the same plug shorting in
    • Latched output stage in the controller

    Checks

    1. 1Trace the harness through the heavy feed from the controller and relay to the glow plugs near the intake manifold looking for chafing against a power wire
    2. 2Inspect for glow plugs drawing too much current from age
    3. 3Unplug the glow plug output and measure the output wire voltage with the output off; it should read zero
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2103Glow plug output error off

    The controller sees the glow plug output not energised when it is commanded on.· Other
    Check soon

    Causes

    • Fuse or relay feeding the glow plug output circuit open
    • Controller output not switching
    • Glow plugs worn and drawing wrong current

    Checks

    1. 1Inspect the heavy feed from the controller and relay to the glow plugs near the intake manifold for breaks, rubbing and corrosion
    2. 2Check the fuse and relay for the glow plug output circuit and test the supply with the key on
    3. 3Measure the voltage at the glow plug output plug while the function is commanded; no voltage means a harness or controller fault
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2107Glow plug output open circuit

    The glow plug output circuit is open.· Open circuit
    Check soon

    Causes

    • Open coil
    • Fuse or feed missing on the supply side
    • Loose or corroded terminal in the plug

    Checks

    1. 1Look at the terminals inside the plug for corrosion, spread contacts or a loose crimp; read the glow plug relay codes on M-series machines for related faults
    2. 2Check the fuse for the glow plug output circuit and confirm it is the right rating
    3. 3Check the supply and return wires of the glow plug output for continuity, flexing the heavy feed from the controller and relay to the glow plugs near the intake manifold as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M2128Glow plug output failure

    The controller has flagged a failure of the glow plug output, which usually follows other output faults.· Other
    Check soon

    Causes

    • Poor connection at the plug
    • Output stage damaged by an earlier fault
    • Coil failed internally

    Checks

    1. 1Look for companion codes such as short, open or overcurrent on the same output, including the glow plug relay codes on M-series machines; they show how the output failed
    2. 2Inspect the heavy feed from the controller and relay to the glow plugs near the intake manifold for rubbing, heat damage and green corrosion in the plugs
    3. 3Check controller power and ground at the plug with the key on and the engine running
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2202Starter output error on

    The controller sees the starter output energised when it is commanded off.· Other
    Check soon

    Causes

    • Short to supply on the starter output output wire
    • Starter solenoid or motor drawing abnormal current
    • Coil or housing stuck energised

    Checks

    1. 1Trace the harness through the start circuit wire from the controller to the starter solenoid looking for chafing against a power wire
    2. 2Inspect for a sticking starter solenoid or a worn starter drawing too much current
    3. 3Unplug the starter output and measure the output wire voltage with the output off; it should read zero
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2203Starter output error off

    The controller sees the starter output not energised when it is commanded on.· Other
    Check soon

    Causes

    • Controller output not switching
    • Failed coil
    • Loose or broken connection
    • Starter solenoid or motor drawing abnormal current
    • Fuse or relay feeding the starter output circuit open

    Checks

    1. 1Inspect the start circuit wire from the controller to the starter solenoid for breaks, rubbing and corrosion
    2. 2Check the fuse and relay for the starter output circuit and test the supply with the key on
    3. 3Measure the voltage at the starter output plug while the function is commanded; no voltage means a harness or controller fault
    4. 4Check the coil resistance and compare it with the same coil on another unit; read the starter relay codes
    5. 5Check the starter solenoid terminals and the battery cable to the starter for heat marks, loose nuts and green crust
    6. 6Look for a sticking starter solenoid or a worn starter drawing too much current and clear it before replacing parts, then verify: turn the key to start with the bar down; the starter should engage on the first try and stop turning as soon as the engine fires
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2207Starter output open circuit

    The starter output circuit is open.· Open circuit
    Check soon

    Causes

    • Loose or corroded terminal in the plug
    • Starter solenoid or motor drawing abnormal current
    • Open coil

    Checks

    1. 1Look at the terminals inside the plug for corrosion, spread contacts or a loose crimp; read the starter relay codes for related faults
    2. 2Check the fuse for the starter output circuit and confirm it is the right rating
    3. 3Check the supply and return wires of the starter output for continuity, flexing the start circuit wire from the controller to the starter solenoid as you test
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat M2228Starter output failure

    The controller has flagged a failure of the starter output, which usually follows other output faults.· Other
    Check soon

    Causes

    • Coil failed internally
    • Poor connection at the plug
    • Wiring fault between the controller and the starter output

    Checks

    1. 1Look for companion codes such as short, open or overcurrent on the same output, including the starter relay codes; they show how the output failed
    2. 2Inspect the start circuit wire from the controller to the starter solenoid for rubbing, heat damage and green corrosion in the plugs
    3. 3Check controller power and ground at the plug with the key on and the engine running
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2302Starter relay error on

    The controller sees the starter relay energised when it is commanded off.· Other
    Check soon

    Causes

    • Driver in the controller latched on
    • Burnt relay contacts after long cranking
    • Contacts fused together after long cranking on a weak battery

    Checks

    1. 1Inspect the base in the relay block beside the controller for heat marks, melted plastic and loose terminals; read the starter output codes
    2. 2Remove the starter relay and measure the coil pin voltage with the key on and the output off; any voltage is a driver or a wiring problem
    3. 3Look at the relay terminals and base for burn marks; a starter relay carries heavy current and shows heat first
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2303Starter relay error off

    The controller sees the starter relay not energised when it is commanded on.· Other
    Check soon

    Causes

    • Burnt relay contacts after long cranking
    • Starter relay coil failed, often after long cranking on a weak battery
    • Poor socket contact in the relay block beside the controller

    Checks

    1. 1Inspect the socket in the relay block beside the controller for burnt, loose or spread terminals; read the starter output codes
    2. 2Check the starter relay fuse and the feed along the heavy start feed through the relay block with a meter and a test light with the key on
    3. 3Test the relay coil out of the socket; it should show a steady resistance and click when energised
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2602Glow plug relay error on

    The controller sees the glow plug relay energised when it is commanded off.· Other
    Check soon

    Causes

    • Burnt glow relay contacts
    • Driver in the controller latched on
    • Contacts fused together after repeated glow cycles on cold mornings

    Checks

    1. 1Inspect the base in the relay block with the other engine relays for heat marks, melted plastic and loose terminals; read the glow plug output codes
    2. 2Trace the glow plug feed through the relay block for chafing against any live feed
    3. 3Remove the glow plug relay and measure the coil pin voltage with the key on and the output off; any voltage is a driver or a wiring problem
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M2603Glow plug relay error off

    The controller sees the glow plug relay not energised when it is commanded on.· Other
    Check soon

    Causes

    • Open glow plug feed fuse or a burnt heavy-current lug
    • Poor socket contact in the relay block with the other engine relays
    • Burnt glow relay contacts

    Checks

    1. 1Inspect the socket in the relay block with the other engine relays for burnt, loose or spread terminals; read the glow plug output codes
    2. 2Check the glow plug relay fuse and the feed along the glow plug feed through the relay block with a meter and a test light with the key on
    3. 3Test the relay coil out of the socket; it should show a steady resistance and click when energised
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M4204Keyless entry no communication

    The controller cannot talk to the keyless entry.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the keyless entry plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M4304Keyless start panel no communication

    The controller cannot talk to the keyless start panel.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the keyless start panel plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat R4304Keyless start panel no communication

    The controller cannot talk to the keyless start panel.· Lost message
    Check soon

    Causes

    • Loose or corroded CAN connector
    • CAN wire broken or shorted
    • Device without power or damaged

    Checks

    1. 1Check the supply and ground at the keyless start panel plug
    2. 2Check the CAN wires for continuity and for shorts to each other
    3. 3Reseat the connectors and cycle the key to see if communication returns
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M8302Wait to start lamp error on

    The controller sees the wait to start lamp switched on when it was commanded off.· Shorted high
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck on
    • Controller output stage failed

    Checks

    1. 1Unplug the wait to start lamp with the key on; if the controller still reads it on, the fault is in the wiring or controller
    2. 2Check the output wire for contact with a power wire along its run
    3. 3Listen and feel for the part energising while it should be off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.

    Good: Open circuit (OL) between them. Any low reading is the short.

  • Bobcat M8303Wait to start lamp error off

    The controller sees the wait to start lamp off when it was commanded on.· Shorted low
    Check soon

    Causes

    • Open or grounded output wire
    • Coil or element failed
    • Blown fuse or missing supply to the circuit

    Checks

    1. 1Check the fuse and supply to the wait to start lamp circuit with the key on
    2. 2Measure the resistance of the part and look for an open or a short to its body
    3. 3Command the function and measure voltage at the plug; none means a wiring or controller fault
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

Shared checks

Checks, in order

  1. 1Load-test the battery and clean the cable ends and the engine ground strap before testing any starting circuit.
  2. 2Key to start and measure voltage at the starter solenoid trigger terminal; voltage present and no crank points to the starter, none points to the relay or controller.
  3. 3Measure glow plug current draw or resistance of each plug, and check the glow relay by swapping it with an identical one.
  4. 4Look at the wait-to-start lamp and its bulb or LED circuit; an always-on lamp may be a lamp driver fault, not a real preheat condition.
  5. 5For keyless codes, check the module connector and supply, and re-pair the key before replacing hardware.

Causes

  • Weak or corroded battery cables and grounds
  • Starter or glow plug relay stuck, burnt or with a loose socket
  • Glow plug or starter solenoid open or shorted
  • Keyless module or key fob not communicating with the controller

Most common here: shorted low (6 of 33)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: The engine cranks slowly, does not crank, will not start cold, or the wait-to-start lamp behaves oddly; a keyless machine may not accept the start request.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.