EF Logo

Bobcat · Controller

Bobcat Display, instrument panel, radio and telematics fault codes

The deluxe and standard display panels, panel buttons, IQ touch screen, left display, radio keypad, telematics module and the E145 gauge panel talk to the machine over CAN. Codes report no communication, software incompatible or outdated, CAN receive and transmit errors, or a display not programmed.

FaultCheckVCO001-11Bobcat · Display, instrument panel, radio and telematics
Code shows hereFAULTVCO001-11

Where this code shows

On touchscreen R-series machines, touch the screen and pick Service Codes from the menu.

What do these codes mean?

Bobcat codes VCO001-11 to R9604 are all about the display, instrument panel, radio and telematics. The most common failure type is lost message (10 of 20); none needs an immediate stop. Start with this check: measure supply and ground at the display connector with the key on.

How urgent are they?

None of the 20 codes here means stop now; all 20 can wait until the shift ends, but find the cause before the next one.

  • Check soon20

What should I check first?

Measure supply and ground at the display connector with the key on.

Shared checks

20 of 20

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Bobcat VCO001-11Gauge panel error

    The controller reports a failure on the gauge panel without saying whether it is open, shorted or stuck, so the display or panel shows no data or the wrong data.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the display connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the gauge panel; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the display connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat VCO002-11E-ECU error

    The controller reports a failure on the e ecu without saying whether it is open, shorted or stuck, so the display or panel shows no data or the wrong data.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the display connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the e ecu; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the display connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat L0102Standard panel button 1 error on

    The controller sees the standard panel button switched on when it was commanded off, so the standard panel button can stay active when nobody asked for it.· Lost message
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed
    • Controller output stage failed and cannot switch off

    Checks

    1. 1Unplug the standard panel button at the panel connector behind the instrument panel with the key on; if the controller still reads it on, the fault is in the wiring or controller.
    2. 2Check the output wire for contact with a power wire along its run.
    3. 3Listen and feel for the button contacts energising while it should be off.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat L0202Standard panel button 2 error on

    Standard panel button 2 error on: same fault as L0102 (the output reads on when it should be off), here on the standard panel button 2.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed

    Checks

    1. 1Unplug the standard panel button 2 with the key on and see whether the controller still reads it on.
    2. 2Test steps: see L0102.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat L0302Standard panel button 3 error on

    Standard panel button 3 error on: same fault as L0102 (the output reads on when it should be off), here on the standard panel button 3.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed

    Checks

    1. 1Unplug the standard panel button 3 with the key on and see whether the controller still reads it on.
    2. 2Test steps: see L0102.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat L0402Standard panel button 4 error on

    Standard panel button 4 error on: same fault as L0102 (the output reads on when it should be off), here on the standard panel button 4.· Other
    Check soon

    Causes

    • Output wire shorted to a live supply
    • Relay or driver stuck closed

    Checks

    1. 1Unplug the standard panel button 4 with the key on and see whether the controller still reads it on.
    2. 2Test steps: see L0102.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat U1011-08Options keypad no communication

    The controller has lost communication with the options keypad, so the display or panel shows no data or the wrong data.· Lost message
    Check soon

    Causes

    • Supply or ground to the unit missing
    • Data wire chafed, open or shorted
    • Unit failed or not programmed
    • Connector corroded at the display connector

    Checks

    1. 1Measure supply and ground at the options keypad connector with the key on.
    2. 2Check the data wires for continuity and shorts, flexing the harness at the display connector.
    3. 3Reseat the connector and clear the code to see whether communication returns.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat U1185-00Radio no communication

    Radio no communication: same fault as R9604 (the controller lost communication), here on the radio.· Lost message
    Check soon

    Causes

    • Supply or ground to the unit missing
    • Data wire chafed, open or shorted

    Checks

    1. 1Measure supply and ground at the radio connector and check its data wires.
    2. 2Test steps: see R9604.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M3304Deluxe panel (mseries) no communication

    The controller has lost communication with the deluxe panel mseries, so the display or panel shows no data or the wrong data.· Lost message
    Check soon

    Causes

    • Supply or ground to the unit missing
    • Data wire chafed, open or shorted
    • Unit failed or not programmed
    • Connector corroded at the display connector

    Checks

    1. 1Measure supply and ground at the deluxe panel mseries connector with the key on.
    2. 2Check the data wires for continuity and shorts, flexing the harness at the display connector.
    3. 3Reseat the connector and clear the code to see whether communication returns.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat R3327IQ touch CAN error

    The controller reports a failure on the iq touch can without saying whether it is open, shorted or stuck, so the display or panel shows no data or the wrong data.· Lost message
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the display connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the iq touch can; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the display connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat R3334IQ touch CAN RX error

    The controller reports a failure on the iq touch can rx without saying whether it is open, shorted or stuck, so the display or panel shows no data or the wrong data.· Lost message
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the display connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the iq touch can rx; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the display connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat R3335IQ touch CAN TX error

    The controller reports a failure on the iq touch can tx without saying whether it is open, shorted or stuck, so the display or panel shows no data or the wrong data.· Lost message
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the display connector
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the iq touch can tx; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the display connector and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat M3372Display software incompatible

    The software in the display does not match the rest of the machine, so the display or panel shows no data or the wrong data.· Part or controller
    Check soon

    Causes

    • Controller replaced with a different software version
    • Update applied to one controller only
    • Wrong software file loaded

    Checks

    1. 1Read the software versions of each controller on the service screen.
    2. 2Update the display to the version that matches the machine through the dealer service tool.
    3. 3Clear the code and restart to confirm the versions agree.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat M3373Display software outdated

    The display is running older software than the machine now requires, so the display or panel shows no data or the wrong data until it is updated.· Part or controller
    Check soon

    Causes

    • Another controller was updated and this one was not
    • Old unit fitted as a replacement

    Checks

    1. 1Read the display software version on the service screen.
    2. 2Update it through the dealer service tool.
    3. 3Restart and confirm the code is gone.
    ControllerPartSupplySignalGround?
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Check power and ground at the module connector with the key on, then its fuses.

    Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.

  • Bobcat M3404Deluxe panel no communication

    The controller has lost communication with the deluxe panel, so the display or panel shows no data or the wrong data.· Lost message
    Check soon

    Causes

    • Supply or ground to the unit missing
    • Data wire chafed, open or shorted
    • Unit failed or not programmed
    • Connector corroded at the display connector

    Checks

    1. 1Measure supply and ground at the deluxe panel connector with the key on.
    2. 2Check the data wires for continuity and shorts, flexing the harness at the display connector.
    3. 3Reseat the connector and clear the code to see whether communication returns.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat R7423Display not programmed

    The display has no valid program loaded, so the controller will not run its functions and the display or panel shows no data or the wrong data.· Other
    Check soon

    Causes

    • New or replaced controller never programmed
    • Software update interrupted
    • Memory corrupted

    Checks

    1. 1Program the display with the dealer service tool and the correct software for the machine model.
    2. 2Check that supply stayed steady during the last update.
    3. 3After programming, calibrate and clear the code.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M7604Left display panel no communication

    The controller has lost communication with the left display panel, so the display or panel shows no data or the wrong data.· Lost message
    Check soon

    Causes

    • Supply or ground to the unit missing
    • Data wire chafed, open or shorted
    • Unit failed or not programmed
    • Connector corroded at the display connector

    Checks

    1. 1Measure supply and ground at the left display panel connector with the key on.
    2. 2Check the data wires for continuity and shorts, flexing the harness at the display connector.
    3. 3Reseat the connector and clear the code to see whether communication returns.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Bobcat L7672Standard panel programming error

    The controller reports a failure on the standard panel programming without saying whether it is open, shorted or stuck, so that panel button does nothing.· Other
    Check soon

    Causes

    • Driver damaged by an earlier short or overload
    • Corroded or loose connector at the panel connector behind the instrument panel
    • Intermittent break in the harness
    • Controller output stage failed

    Checks

    1. 1Read the other active codes for the standard panel programming; a short or open code beside this one narrows the cause.
    2. 2Reseat the connector at the panel connector behind the instrument panel and clear the code to see whether it returns.
    3. 3Measure voltage at the plug while the output is commanded to see whether the controller drives it at all.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Bobcat M8804Telematics not connected

    The controller sees an open circuit on the telematics, so no current can flow through it and the display or panel shows no data or the wrong data.· Open circuit
    Check soon

    Causes

    • Pin backed out of the connector or plug not latched at the display connector
    • Wire broken inside its insulation near a bend or clamp
    • The display supply burnt open or its internal lead broken

    Checks

    1. 1Check that the telematics connector at the display connector is fully seated and its lock tab engaged.
    2. 2Measure the resistance of the display supply with the plug off; an infinite reading confirms an open.
    3. 3Check continuity of each wire from the telematics plug back to the controller connector, flexing the harness as you go.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.

    Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.

  • Bobcat R9604Radio no communication

    The controller has lost communication with the radio, so the display or panel shows no data or the wrong data.· Lost message
    Check soon

    Causes

    • Supply or ground to the unit missing
    • Data wire chafed, open or shorted
    • Unit failed or not programmed
    • Connector corroded at the display connector

    Checks

    1. 1Measure supply and ground at the radio connector with the key on.
    2. 2Check the data wires for continuity and shorts, flexing the harness at the display connector.
    3. 3Reseat the connector and clear the code to see whether communication returns.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

Shared checks

Checks, in order

  1. 1Measure supply and ground at the display connector with the key on.
  2. 2Check CAN wires for chafing and water at the display and controller connectors.
  3. 3Update or program the display software when an incompatible or outdated message shows.
  4. 4Swap with a known good display if available to see whether the code moves.
  5. 5Check radio and telematics module power fuses.

Causes

  • Display supply or ground missing
  • CAN wiring damaged between the display and controller
  • Software mismatch after a controller update
  • Display or touch screen failed

Most common here: lost message (10 of 20)

Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

When to stop

You'll notice: The display goes blank or freezes, shows a software warning, or loses its menus and service codes screen.

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.