The formula
kW = kVA × power factor; kVA = kW ÷ power factor.
What it works out
Convert apparent power (kVA) and real power (kW).
Why it matters
Match generator ratings to the load.
How to use it
- Under Conversion Direction, choose kVA → kW or kW → kVA.
- Type the number in the Value field: the kVA if you chose kVA → kW, the kW if you chose kW → kVA.
- Set the Power Factor. Use 0.8 for a generator unless the nameplate says otherwise; the default is 0.8.
- Read kW and kVA. Use the table for a quick look at common generator sizes.
The formula
kW = kVA × power factor. kVA = kW ÷ power factor. The same formulas apply to single-phase and 3 phase ratings, as long as the kVA and kW are both total figures for the whole machine.
What power factor means
kVA is the apparent power the generator or transformer must supply, and kW is the useful power the load actually uses. Power factor is the ratio between them, always between 0 and 1. Motors, compressors and welders pull the power factor down, while resistive loads like heaters are close to 1. The lower the power factor, the more kVA you need for the same kW.
Generator ratings on UAE sites
Generators are normally rated in kVA at a power factor of 0.8, so a set quoted in kVA delivers 80% of that number in kW. Check whether a quoted figure is a prime or a standby rating, since they differ. To pick a generator for a whole site, including motor starting and spare capacity, use the generator size calculator rather than this conversion alone.
Worked examples
- A 100 kVA generator at a power factor of 0.8 delivers 80 kW.
- A 500 kVA site generator at 0.8 gives 400 kW of usable power.
- A 60 kW load at a power factor of 0.8 needs a generator of at least 75 kVA.
- The same 60 kW load at a better power factor of 0.9 needs only 66.67 kVA.
Frequently asked questions
How do I convert kVA to kW?
Multiply the kVA by the power factor. At a power factor of 0.8, 100 kVA is 80 kW.
How do I convert kW to kVA?
Divide the kW by the power factor. At 0.8, 80 kW is 100 kVA.
What power factor should I use for a generator?
Use 0.8, the standard rating for most generators, unless the nameplate or the supplier gives another value.
Is the conversion different for 3 phase?
No. For a 3 phase machine, kVA and kW are the total for all three phases, and kW = kVA × power factor in the same way.
Is kVA the same as kW?
Only at a power factor of 1. For most real loads kW is lower than kVA, which is why a generator in kVA can supply fewer kW than its number suggests.
Add this calculator to your website
Copy the code and paste it into your page. The calculator is free and works as it does here.
<iframe src="https://www.equipmentsfinder.com/embed/field-tools/kva-to-kw" title="kVA to kW calculator" width="100%" height="620" style="border:0;max-width:720px" loading="lazy"></iframe> <p style="font-size:12px"><a href="https://www.equipmentsfinder.com/field-tools/kva-to-kw">kVA to kW calculator</a> by <a href="https://www.equipmentsfinder.com">EquipmentsFinder</a></p>