Thermo King · Temperature control (SR-2/SR-3/SR-4)
Thermo King Temperature deviation, doors, defrost and fans fault codes
This page covers temperature control and airflow: temperature deviation alarms, door open alarms, the defrost cycle and damper, evaporator fan speeds and the remote evaporator and condenser fans. These alarms tell that the evaporator temperature is high or that the temperature difference between the return and discharge air is abnormal while the unit runs.
More about these partsLess
A door switch tells the controller when a compartment door is open. The controller starts a defrost to clear frost from the coil and ends it on coil temperature or on time. The evaporator fans run at low or high speed to move air through the box. Multi-temp units use remote evaporator fans and the unit uses condenser fans.
Where this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
What do these codes mean?
Thermo King codes dr1 to 506 are all about the temperature deviation, doors, defrost and fans. The most common failure type is lost message (2 of 18); none needs an immediate stop. Start with this check: check the doors and seals and any open air leak.
How urgent are they?
None of the 18 codes here means stop now; 14 can wait until the shift ends, but find the cause before the next one; 4 are information only.
- Check soon14
- Info4
What should I check first?
Check the doors and seals and any open air leak
Shared checks18 of 18
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Thermo King dr1Door 1 open or door switch 1 failure
Door switch 1 shows the door open or the switch has failed. Close the door and report the alarm at the end of the day.· OtherOtherCheck soonCauses
- Door open
- Door switch failed
Checks
- 1Close the door and see whether the alarm clears
- 2Check the door switch and wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King dr2Door 2 open or door switch 2 failure
Door switch 2 shows the door open or the switch has failed. Close the door and report the alarm at the end of the day.· OtherOtherCheck soonCauses
- Door open
- Door switch failed
Checks
- 1Close the door and see whether the alarm clears
- 2Check the door switch and wiring
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 09High evaporator temperature
The evaporator coil is warmer than expected while the unit is cooling or has been running a while, which indicates the cooling cycle is not pulling heat out of the coil as it should.· OtherOtherCheck soonCauses
- Refrigerant charge low from a slow leak
- Compressor not pumping because of worn valves
- Expansion valve stuck open or hunting
Checks
- 1Compare the coil temperature on the display with a probe thermometer on the coil
- 2Attach gauges and check suction and discharge pressure against the unit's normal range
- 3Check the sight glass for bubbles that mean low charge
- 4Check the compressor drive belt or clutch for slip
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 14Defrost terminated by time
A defrost cycle ended because the time limit ran out instead of the coil sensor reaching the termination temperature. That suggests the coil did not clear fully or the sensor is not reading right.· OtherOtherInfoCauses
- Coil sensor reading low or not attached to the coil
- Defrost heat (hot gas or electric heat) not strong enough
- Damaged or stuck defrost damper
- Very heavy frost build-up from a door left open
Checks
- 1Open the evaporator and see whether ice remains on the coil after a defrost
- 2Check the coil sensor is clamped to the coil and gives sensible readings
- 3Verify the hot gas valve or heater really operates during defrost
- 4Check the defrost damper moves freely by hand
- 5Look for causes of heavy icing such as a leaking door seal
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 29Defrost damper circuit check
The controller found a problem in the defrost damper circuit, the output that moves the damper door during defrost to keep warm air from the box.· OtherOtherCheck soonCauses
- Damper solenoid or motor open
- Connector pin loose at the damper
- Harness chafed near the evaporator
Checks
- 1Command defrost in a test mode and watch whether the damper moves
- 2Measure the resistance of the damper coil or motor
- 3Check voltage at the damper plug when energised
- 4Inspect the harness at the evaporator for rubbing
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 30Defrost damper stuck closed
The controller detects the defrost damper is not opening back up after defrost, which would block evaporator airflow.· OtherOtherCheck soonCauses
- Damper door frozen or physically jammed
- Linkage broken or off
- Actuator failed
Checks
- 1Open the evaporator and move the damper by hand to test for binding
- 2Look for ice packed around the damper hinge and the drain that may hold it shut
- 3Check the actuator or solenoid output when commanded
- 4Check the damper linkage clips and pins for breakage that leaves the door shut
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 46Check air flow
The controller thinks air flow across the evaporator is below what it should be, based on temperature difference and fan status.· OtherOtherCheck soonCauses
- Evaporator coil iced or blocked
- Fan belt or motor slow
- Load blocking the return air
Checks
- 1Check the coil for ice and run a defrost cycle
- 2Check the evaporator fan rotates in the right direction and at the right speed
- 3Look for load blocking the return air opening
- 4Check the air chute and ducting for damage, tears or loose sections
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 56Check evaporator fan low speed
The controller found a fault in the evaporator fan low speed circuit or motor, meaning low speed air flow may be weak or absent.· OtherOtherCheck soonCauses
- Fan motor failing
- Low speed relay or resistor failed
- Harness fault in the fan feed
Checks
- 1Run low speed and check the fan turns freely and is not rubbing the shroud
- 2Measure the fan motor current draw in low speed and compare with high speed
- 3Test the low speed relay or resistor for pull-in and for proper contact
- 4Inspect the fan plug for burnt pins and the wires for heat damage
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 57Check evaporator fan high speed
The controller found a fault in the evaporator fan high speed circuit or motor, so high speed air flow may be weak or absent and capacity suffers.· OtherOtherCheck soonCauses
- Fan motor bearings or windings failing
- High speed contactor or relay stuck
- Wire to the motor damaged
Checks
- 1Run high speed and listen for bearing noise at the fan
- 2Compare the motor current with the rated value in the manual
- 3Check the high speed contactor contacts for pitting or sticking when energised
- 4Inspect the fan wiring for chafing where it passes the evaporator frame
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 65Abnormal temperature differential
The temperature difference between return and discharge air is outside what is normal for the mode, meaning poor heat transfer or a sensor problem.· OtherOtherCheck soonCauses
- Air short-circuiting at the evaporator
- Faulty return or discharge sensor
- Loss of airflow
Checks
- 1Compare the two air sensors against a thermometer
- 2Check the evaporator airflow by feeling the discharge and looking at the fan
- 3Inspect the air chute for tears that let air short-circuit back to the coil
- 4Check the refrigeration cycle pressures against a known good running unit
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 104Remote fan speed check (zone)
The speed signal that a remote evaporator fan in a multi-temp zone returns to the controller is out of range, so the controller cannot confirm the fan is turning at the commanded speed.· OtherOtherCheck soonCauses
- Remote fan motor speed feedback failed
- Speed signal wire damaged between the zone fan and the controller
Checks
- 1Read the zone fan speed on the display and compare it with the commanded speed.
- 2Check the zone fan plug and the speed wire for chafing and corrosion.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 108Door open timeout
A door switch has reported the compartment door open longer than the allowed time, so the unit is stopped or held in door-open mode.· Lost messageLost messageInfoCauses
- Door really left open
- Door switch stuck or misadjusted
- Door switch wiring shorted
Checks
- 1Check the door is fully closed and latched, with the seal sitting properly
- 2Check the door switch is activating when the door closes by watching its input
- 3Test the door switch wiring for shorts to ground or an open circuit
- 4Replace the door switch if it stays open with the door shut
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Thermo King 112Remote fans check (zone)
A remote evaporator fan in a multi-temp zone is not running when the controller calls for it, so airflow and temperature control in that zone drop.· OtherOtherCheck soonCauses
- Remote fan motor failed or seized
- Fuse or relay of the zone fan circuit open
Checks
- 1Check the fuse and relay of the zone fan circuit.
- 2Run the remote fans from the diagnostics menu and see which one does not move.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 147Multi-temp fan speed control output check (zone)
The output that sets the speed of the zone fans on a multi-temp unit is open or shorted, so the fans cannot be set to the speed the controller wants.· OtherOtherCheck soonCauses
- Fan speed control wire open or shorted
- Controller speed output failed
Checks
- 1Check the speed control wire for a break or a short at the fan plug.
- 2Test the speed output in diagnostics with a meter while the fan is commanded.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 500Host evaporator blower low speed check
The low speed circuit of the host evaporator blower is flagged. The source lists the alarm as not implemented, so it is not expected on current units.· OtherOtherInfoCauses
- Blower low speed relay or wiring
- Blower motor winding
Checks
- 1Check the blower low-speed wiring and relay
- 2Confirm the unit software version supports the alarm
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 501Host evaporator blower high speed check
The high speed circuit of the host evaporator blower is flagged. The source lists the alarm as not implemented, so it is not expected on current units.· OtherOtherInfoCauses
- Blower high speed relay or wiring
- Blower motor winding
Checks
- 1Check the blower high-speed wiring and relay
- 2Confirm the unit software version supports the alarm
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 505Roadside condenser fan motor speed circuit check
The speed circuit of the roadside condenser fan motor is faulty, so the controller cannot regulate condenser airflow on that side. Head pressure control is lost on that side and the compressor can run hot.· Lost messageLost messageCheck soonCauses
- Roadside fan motor failed
- Speed signal wire to the roadside motor damaged
Checks
- 1Run the roadside condenser fan in diagnostics and see whether it turns.
- 2Check the roadside motor plug and wiring for corrosion and chafing.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Thermo King 506Curbside condenser fan motor speed circuit check
Same speed-circuit fault as alarm 505, but on the curbside condenser fan motor, so the controller cannot regulate condenser airflow on the curbside.· OtherOtherCheck soonCauses
- Curbside fan motor failed
- Speed signal wire to the curbside motor damaged
Checks
- 1Run the curbside condenser fan in diagnostics; if the roadside one runs, the fault is local to this side.
- 2Check the curbside motor plug and wiring for corrosion and chafing.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Check the doors and seals and any open air leak
- 2Check the door is fully closed and latched
- 3Start a manual defrost and watch whether it ends on coil temperature or on time
- 4Run the fans at each speed in diagnostics and listen for movement
- 5Run the fans in diagnostics and listen for movement
- 6Look at the evaporator coil for ice and the air path for blockage
- 7Watch the door switch input change when the door opens and closes
Causes
- Door left open or seal damaged
- Door left open or not latched
- Coil sensor reading wrongly so defrost ends on time
- Fan motor failed
Most common here: lost message (2 of 18)
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
When to stop
You'll notice: The load warms up or the controller shows an abnormal temperature split on the display.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.
