Thermo King · Cryogenic CR units
Thermo King Cryogenic CR coolant system fault codes
This page covers the cryogenic CR units that cool with CO2. Cryogenic CR units cool with a stored coolant such as CO2 instead of a compressor.
Where this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
What do these codes mean?
Thermo King codes 27 to 178 are all about the cryogenic CR coolant system. 1 needs an immediate stop. Start with this check: check the coolant tank level against the gauge.
How urgent are they?
1 of 12 codes here means stop now; 10 can wait until the shift ends, but find the cause before the next one; 1 is information only.
- Stop now1
- Check soon10
- Info1
What should I check first?
Check the coolant tank level against the gauge
Shared checks12 of 12
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Thermo King 27Vapor motor RPM high (CR)
On Thermo King cryogenic (CR) units, the vapor motor that drives the fans is spinning faster than allowed. The controller treats it as an overspeed fault.· Real conditionReal conditionStop nowCauses
- Speed control valve stuck open
- Excess CO2 or nitrogen vapor feeding the motor
- Speed sensor misreading
Checks
- 1Check the vapor motor speed on the display against a hand tachometer
- 2Inspect the vapor supply valve for sticking open
- 3Check the speed sensor and its wiring for noise or damage
- 4Clear the alarm and watch whether speed climbs again
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Thermo King 100Heater fan failure (CR)
The fan that moves air over the heater on a CR unit has failed or is drawing the wrong current. Heating performance falls.· OtherOtherCheck soonCauses
- Heater fan motor failed
- Blown fuse or loose plug
Checks
- 1Check the fan fuse and connector
- 2Run the fan from the diagnostics menu and listen for movement
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 101Controlling on evaporator coil outlet temperature (CR)
On a CR unit the controller is using the coil outlet temperature to control, because the normal sensor cannot be used. The operator should watch the box temperature by hand.· OtherOtherCheck soonCauses
- Return or discharge air sensor failed
- Sensor lead damaged
Checks
- 1Look for the sensor alarm that caused the fall-back and fix that first
- 2Compare the display with a hand thermometer in the load space
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 102Low evaporator coil temperature (CR)
The evaporator coil of a CR unit has dropped below its allowed temperature. The unit may shut down the zone to prevent freezing the coil or the load.· OtherOtherCheck soonCauses
- Too much cryogen flow through the coil
- Coil sensor reading low
Checks
- 1Check the coolant flow control and the coil temperature on the display
- 2Look for an iced or blocked coil
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 103Low heater fuel level (CR)
The fuel level for the heater on a CR unit has dropped to the low mark. The unit still runs but heating will stop when the tank is empty.· OtherOtherCheck soonCauses
- Heater tank low on fuel
- Fuel level sensor reading wrongly
Checks
- 1Top up the heater fuel and see whether the alarm clears
- 2Compare the gauge with a dipstick check
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 123Evaporator coil inlet temperature sensor check (CR)
On a cryogenic CR unit the sensor that reads the coolant temperature entering the evaporator coil is out of range. The controller loses part of its picture of the coil.· OtherOtherCheck soonCauses
- Sensor lead damaged at the coil
- Corroded sensor plug
Checks
- 1Compare the coil inlet reading with the outlet sensor on the display
- 2Check the sensor wiring for chafing and the plug for corrosion
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 124Evaporator coil outlet temperature sensor check (CR)
On a cryogenic CR unit the sensor that reads the temperature leaving the evaporator coil is out of range. Control continues on the other sensors, so the alarm is for the end-of-day report.· OtherOtherInfoCauses
- Sensor lead damaged near the coil
- Failed sensor
Checks
- 1Read the sensor resistance at the controller plug and compare with the inlet sensor
- 2Inspect the lead for chafing along its run
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 125Tank level sensor check (CR)
The level sensor in the cryogen tank of a CR unit is giving an out-of-range reading. The controller cannot tell how much coolant is left.· OtherOtherCheck soonCauses
- Level sensor wire open or shorted
- Sensor failed
Checks
- 1Check the level sensor plug and wiring
- 2Compare the display with the tank gauge if one is fitted
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 126Back pressure regulator check (CR)
The back pressure regulator that holds the pressure in the coil of a CR unit is not behaving as expected. Temperature control can become uneven.· Lost messageLost messageCheck soonCauses
- Regulator valve sticking
- Wiring fault to the regulator solenoid
Checks
- 1Check the regulator wiring and coil
- 2Watch the coil pressure while commanding the valve
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Thermo King 176Evaporator pressure sensor check (CR)
The sensor that measures evaporator pressure on a CR unit reports an unlikely value. The controller cannot regulate the coil pressure reliably.· OtherOtherCheck soonCauses
- Pressure sensor open or shorted
- Blocked sensor port
Checks
- 1Check the sensor plug and supply at the sensor
- 2Read the pressure on the display with the unit off
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 177CO2 tank pressure sensor check (CR)
The pressure sensor on the CO2 tank of a CR unit reports an unlikely value. The controller cannot judge how much coolant remains.· OtherOtherCheck soonCauses
- Sensor wiring damaged
- Sensor failed
Checks
- 1Check the sensor plug and wiring
- 2Compare the reading against the tank gauge
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 178Low CO2 fuel level (CR)
The CO2 tank of a CR unit is running low, so the unit may soon lose its cooling. This is a service reminder to refill the tank.· OtherOtherCheck soonCauses
- CO2 tank nearly empty
- Level sensor reading low
Checks
- 1Refill the tank and clear the alarm
- 2Check the level reading after refilling
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Check the coolant tank level against the gauge
- 2Check the sensors and their wiring for damage
- 3Check the valve operation from diagnostics
- 4Check the heater and its fan run when commanded
Causes
- Coolant tank low
- Sensor wiring damaged
- Valve stuck
- Heater or fan failed
When to stop
You'll notice: The CR unit may cool poorly or shut down the zone, with the alarm number on the display.
Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.