Genie · Switch and joystick faults at startup (U)
Genie Fault Code U033
PCON drive joystick not centred at startup
What does Genie code U033 mean?
The drive joystick signal was outside the calibration window when the machine started. Drive and steer from the platform are blocked until the joystick is centred and power is cycled. Urgency: check soon - the machine may derate or limit a function. Check first: let the joystick spring back to centre, cycle the key and see whether the code returns.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Let the joystick spring back to centre, cycle the key and see whether the code returns.
Then 4 more checksWhere this code shows
Scissors: read the code on the platform LED display or the ground control LCD.
Checks
0 of 5 done
Causes
- Joystick held or sitting off centre when the machine was switched on
- Joystick centre position drifted out of the calibration window
- Joystick replaced or the control box knocked without recalibrating
- GCON joystick input fault
How it failed
You'll notice: The drive joystick was off its centre calibration range at power-up, so platform drive and steer are blocked until it is centred and the key is cycled.
Part or controllerRead from how the source describes the code
The controller reports a part, module or its software as faulty or not responding.
- Meter test
- Check power and ground at the module connector with the key on, then its fuses.
- Good result
- Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
When to stop
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Control circuits: power, horn, alarm, foot switch and drive joystick
- P013PCON power return: short to battery negativeShorted highStop now
- P015PCON power return: short to battery positiveShorted highStop now
- P018PCON power: short to battery negativeShorted highStop now
- P019PCON power: short to battery positiveShorted highStop now
- U033PCON drive joystick not centred at startupPart or controllerCheck soon
- U034PCON drive joystick signal high at startupShorted highCheck soon
- U035PCON drive joystick signal low at startupShorted highCheck soon
- U037Foot switch pressed at startupReal conditionCheck soon
- U038Foot switch shorted to battery positiveShorted highCheck soon
Show the other 9 codesHide the other codes
- P001Switched power #1: short to battery negativeShorted highStop now
- P003Switched power #1: short to battery positiveShorted highStop now
- P004Horn: short to battery negativeShorted highInformation
- P005Horn: open circuitOpen circuitInformation
- P006Horn: short to battery positiveShorted highInformation
- P007Ground control alarm: short to battery negativeShorted highInformation
- P009Ground control alarm: short to battery positiveShorted highInformation
- U039Foot switch open or shorted negativeShorted highCheck soon
- U040Foot switch timeout or deck switch pressedLost messageCheck soon
Other Genie codes: Switch and joystick faults at startup (U)
Related on Equipments Finder
Source
This source lists U033 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Genie GS-1530/1532/1930/1932/2032/2632 slab scissors with SmartLink (GSDS) controls.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.