Thermo King · Controller (SR-2/SR-3/SR-4)
Thermo King Controller memory, software, status and resets fault codes
This page covers the unit controller itself: memory and software faults, status alarms, resets and unknown alarms. The controller runs memory tests and checks its software on start-up.
More about these partsLess
These alarms report the state of the controller: a clock reset, internal fault, reset to defaults, restart, forced operation, test mode timeout and unknown or multiple alarms.
Where this code shows
Press the alarm key or open the Alarms menu on the controller display to list active alarms.
What do these codes mean?
Thermo King codes SOF to 158 are all about the controller memory, software, status and resets. Most are part or controller faults; 7 need an immediate stop. Start with this check: cycle the unit power and see whether the alarm returns.
How urgent are they?
7 of 19 codes here mean stop now; 5 can wait until the shift ends, but find the cause before the next one; 7 are information only.
- Stop now7
- Check soon5
- Info7
What should I check first?
Cycle the unit power and see whether the alarm returns
Shared checks19 of 19
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Thermo King SOFMicroprocessor software failure
The controller microprocessor software has failed. The unit may stop.· Part or controllerPart or controllerStop nowCauses
- Software corruption
- Controller fault
Checks
- 1Cycle the unit power
- 2Reload the software or replace the controller
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King tCOElectronic control module internal temperature exceeds limit
The temperature inside the electronic control module is above its limit. The unit may stop to protect the controller.· Real conditionReal conditionStop nowCauses
- Controller in a hot spot or poor ventilation
- Controller internal fault
Checks
- 1Check the controller location and airflow around it
- 2Let it cool and restart
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Thermo King 28Pretrip or self check abort
A pretrip test or self check was started and then stopped before it finished, by a key press or by a fault that prevented completion.· OtherOtherInfoCauses
- Operator interrupted the pretrip
- Another active alarm aborted the test
- Engine or unit stopped during the test
Checks
- 1Clear all alarms and run the pretrip again from the start
- 2Watch for any alarm that appears during the test steps
- 3Check battery voltage holds up during the test
- 4Do not open doors or power down until it finishes
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 50Reset clock
The controller real time clock has lost its time, usually after a power loss, and needs to be set again.· OtherOtherInfoCauses
- Battery was disconnected
- Controller backup battery flat
- Controller reset
Checks
- 1Set the clock through the menu and confirm it holds
- 2Check the main battery connections are tight so the controller keeps its supply
- 3Replace the controller backup battery if it keeps resetting
- 4Watch the supply voltage while starting to check for drop-outs that reset the clock
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 54Test mode timeout
A diagnostic or test mode on the controller timed out and the unit left it. The source says to clear the alarm and restart the unit.· Lost messageLost messageInfoCauses
- Test mode left running too long
- Interrupted pretrip or test
Checks
- 1Clear the alarm and restart the unit
- 2Check that the unit goes back to normal control
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Thermo King 68Internal controller fault code
The microprocessor logged an internal fault code of its own. This points to the controller, not a sensor or valve, and often goes with erratic behaviour.· Erratic or implausibleErratic or implausibleCheck soonCauses
- Corrupted controller memory after a power spike
- Low or noisy supply voltage
- Failed controller board
Checks
- 1Check the battery voltage and ground connections to the controller
- 2Clear alarms and power-cycle the controller, then see whether the internal fault code repeats
- 3Reload or update the software if the alarm repeats
- 4Swap in a known-good controller to prove the fault
The reading against the band the controller allows. Meter test
Watch the live value on the service tool while you flex the harness and tap the connector.
Good: A steady value that tracks the real condition. A jump while flexing is the loose pin or wire.
Thermo King 74Controller reset to defaults
The controller lost or rejected its stored settings and reloaded the factory default configuration, so setpoints, options and calibrations may all be gone.· Part or controllerPart or controllerCheck soonCauses
- Battery disconnected or dipped during cranking
- Corrupted memory in the controller
- Software update that did not finish
- Controller backup battery flat
Checks
- 1Check the configuration and setpoint and re-enter them
- 2Inspect battery terminals and supply to the controller
- 3Clear alarm in the maintenance or guarded access menu
- 4Re-flash the software if it repeats and test supply voltage during crank
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 75Controller RAM failure
The controller found a fault in its working memory (RAM) during its self test, so it cannot be trusted to run the unit.· Part or controllerPart or controllerStop nowCauses
- Failed controller board memory
- Voltage spike during jump start
- Moisture damage inside controller
Checks
- 1Power-cycle the controller and clear the alarm
- 2Check the supply voltage and ground at the controller plug
- 3Inspect the controller case and connector for water ingress and corrosion
- 4Replace the controller if the alarm returns after a power cycle
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 76Controller EPROM failure
The controller found a fault in its program memory (EPROM) during self test, meaning the stored software may be damaged.· Part or controllerPart or controllerStop nowCauses
- Software memory chip failed
- Interrupted software update
- Voltage spike during programming
Checks
- 1Clear the alarm and power-cycle the controller
- 2Reload the software with the service tool and confirm the load completes
- 3Check the supply voltage while loading, since a drop corrupts the memory
- 4Replace the controller if the software will not load or the alarm remains
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 77Controller EPROM checksum failure
The stored program in the controller failed its checksum, which means the software code has changed or is corrupted.· Part or controllerPart or controllerStop nowCauses
- Corrupted software load
- Controller memory fault
- Supply interruption during update
Checks
- 1Reload the correct software version with the service tool
- 2Confirm the software file matches the unit model and controller type
- 3Check the supply voltage during loading to avoid another bad checksum
- 4Replace the controller if the checksum fails again
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 78Data log EPROM failure
The memory that holds the data logger records is failing, so recorded temperatures and events may be lost or unreadable.· Part or controllerPart or controllerCheck soonCauses
- Data log memory chip failure
- Controller board damage
- Corrupt log data
Checks
- 1Try downloading the data log to see if it reads
- 2Clear the data log if the service tool allows it and see whether the memory recovers
- 3Check the supply and ground to the controller during the download attempt
- 4Replace the controller or logger module if memory stays faulty
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 79Internal data logger overflow
The data logger memory filled and began overwriting older records, so the oldest history is gone.· Part or controllerPart or controllerInfoCauses
- Log not downloaded for a long time
- Log memory full
- Log interval set very short
Checks
- 1Download the data log to the service tool or software
- 2Clear the stored data after downloading it so the logger starts fresh
- 3Review the logging interval, because a very short interval fills memory sooner
- 4Confirm the logger clock is correct so new records have the right time stamps
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 84Restart null
The unit stopped and restarted in null mode to protect itself, because the temperature is near setpoint and no heat or cool is needed.· OtherOtherInfoCauses
- Normal cycle sentry operation at setpoint
- Engine restarted after reaching null limits
- Controller set to cycle mode
Checks
- 1Check if the unit is in Cycle Sentry rather than continuous mode
- 2Check setpoint and box temperature are close to each other
- 3Look for other alarms in the log that may have caused the engine to restart
- 4Switch to continuous run if frequent cycling is unwanted
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 85Forced unit operation
The unit is running because someone forced it into operation, bypassing the normal control logic. It is a status note for the service record.· OtherOtherInfoCauses
- Service technician forced the operation
- Forced mode left on
Checks
- 1Check whether a forced mode is active in the menu
- 2Return the unit to normal control
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 114Multiple alarms, cannot run
The unit has so many active alarms that the controller cannot run it safely, and refuses to start until they are cleared.· OtherOtherStop nowCauses
- Several sensor failures together
- Major supply or ground fault
- Harness damage affecting many circuits
Checks
- 1Read all active alarms in the list and fix them in order, starting with the earliest
- 2Check the supply and ground to the controller
- 3Inspect the main harness for damage that can affect many circuits at once
- 4Clear the alarms and try a restart to see whether the unit can run
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 145Lost controller ON feedback signal
The controller no longer receives the ON feedback signal that confirms the unit is switched on from the control panel or remote switch.· OtherOtherCheck soonCauses
- ON switch contacts worn or dirty
- Wire between switch and controller broken
- Connector pin backed out
Checks
- 1Check the ON switch operates and gives continuity when closed
- 2Test the signal wire from the switch to the controller for an open
- 3Inspect the controller connector for backed-out pins
- 4Compare input state in the diagnostic menu while operating the switch
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Thermo King 149Alarm not identified
The controller raised an alarm it cannot name. Read the alarm list and the unit software version to find what was reported.· Part or controllerPart or controllerCheck soonCauses
- New alarm not in the controller table
- Software mismatch
Checks
- 1Read all active alarms from the controller
- 2Check the controller software version
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 153Expansion module flash load failure
The software load of the expansion module failed. The module may run old or incomplete software.· Part or controllerPart or controllerInfoCauses
- Interrupted software load
- Module fault
Checks
- 1Reload the software
- 2Replace the module if it fails again
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Thermo King 158Primary software failed to load
The controller could not load its main application software at start-up, so it cannot run the unit normally.· Part or controllerPart or controllerStop nowCauses
- Software file corrupted
- Update interrupted by loss of power
- Controller memory fault
Checks
- 1Reload the software with the service tool using a stable power supply
- 2Confirm the software version suits the unit and controller
- 3Check supply and ground voltage at the controller during the load
- 4Replace the controller if loading fails again
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Shared checks
Checks, in order
- 1Cycle the unit power and see whether the alarm returns
- 2Read the full alarm list and note the order they appeared
- 3Reload the controller software with the service tool
- 4Check the supply voltage at the controller with a meter
- 5Check the supply voltage at the controller
- 6Check the settings that were lost or changed after the reset
- 7Replace the controller if the memory test keeps failing
Causes
- Memory chip failed
- Power loss or supply dip
- Software load interrupted
- Controller internal fault
Most codes here: part or controller (10 of 19)
Check power and ground at the module connector with the key on, then its fuses.
When to stop
You'll notice: The unit may stop, reset to defaults or refuse to start until the controller software is fixed.
Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.