EF Logo

Thermo King · Charging system (SR-2/SR-3/SR-4)

Thermo King Alternator, battery and battery charger fault codes

This page covers the charging system: alternator and battery alarms, and the battery charger input, output, electrical, temperature and status alarms. The alternator charges the unit battery and the controller watches the voltage.

More about these parts

The on-board battery charger takes mains power and charges the unit battery. These alarms report electrical faults in the battery charger: shorts, overvoltage and out of range voltages. These alarms report the battery charger temperature and status: low temperature, derating, charging a low battery and sensor faults.

FaultCheck25Thermo King · Alternator, battery and battery charger
Code shows hereFAULT25

Where this code shows

Press the alarm key or open the Alarms menu on the controller display to list active alarms.

What do these codes mean?

Thermo King codes bAt to 553 are all about the alternator, battery and battery charger. The most common failure type is shorted low (2 of 22); 1 needs an immediate stop. Start with this check: measure the battery voltage at rest and with the engine running.

How urgent are they?

1 of 22 codes here means stop now; 11 can wait until the shift ends, but find the cause before the next one; 10 are information only.

  • Stop now1
  • Check soon11
  • Info10

What should I check first?

Measure the battery voltage at rest and with the engine running

Shared checks

22 of 22

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Thermo King bAtLow battery voltage

    The battery voltage is low.· Shorted low
    Stop now

    Causes

    • Weak battery
    • Alternator not charging

    Checks

    1. 1Measure the battery voltage
    2. 2Check the alternator output
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Thermo King 25Alternator check

    The charging output from the unit alternator is wrong, either not charging at all or giving a voltage the controller does not accept.· Other
    Check soon

    Causes

    • Alternator drive belt loose or broken
    • Alternator excite wire open or its fuse blown
    • Voltage regulator failed
    • Battery cables corroded

    Checks

    1. 1Check the alternator belt tension and condition
    2. 2Measure battery voltage with the engine running
    3. 3Watch battery voltage with the engine running; it should rise above its resting voltage
    4. 4Check the excite circuit wire and fuse at the alternator
    5. 5Clean the battery cables and the main alternator output lug
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 61Low battery voltage

    The battery voltage seen by the controller dropped below the minimum it needs, risking a failed start or controller reset.· Other
    Check soon

    Causes

    • Battery discharged or worn
    • Charging system not working
    • Corroded or loose cables

    Checks

    1. 1Load test the battery and check its age, since old batteries fail under cranking load
    2. 2Check the alternator output with the engine running
    3. 3Clean and tighten the battery cables and the engine ground strap
    4. 4Check for a parasitic drain with the unit off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 120Check alternator excite circuit

    A fault is found in the alternator excite circuit, which the controller uses to turn the alternator on.· Other
    Check soon

    Causes

    • Excite wire open or shorted
    • Fuse blown
    • Alternator regulator fault

    Checks

    1. 1Check the alternator excite wire and its fuse for continuity
    2. 2Measure the voltage at the alternator excite terminal with the key on
    3. 3Check the voltage regulator in the alternator for correct operation
    4. 4Inspect the alternator connector for corrosion and loose terminals
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 159Check battery condition

    The controller judged the battery condition to be poor, for example low voltage after starting or a battery that does not recover between starts.· Shorted low
    Check soon

    Causes

    • Battery aged and unable to hold charge
    • Charging system output low
    • Loose or corroded terminals
    • Parasitic load draining the battery

    Checks

    1. 1Load test the battery and check its state of charge
    2. 2Measure the alternator output with the engine running
    3. 3Clean the terminals and check cable lugs for heat discoloration
    4. 4Check for any accessory load left switched on while the unit is parked and off
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

    Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.

  • Thermo King 519Battery charger input power check

    The input power to the battery charger is out of range.· Other
    Check soon

    Causes

    • Supply plug or cable damaged
    • Low supply voltage

    Checks

    1. 1Check the supply voltage and cable to the charger
    2. 2Check the charger input fuse
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 520Battery charger output power check

    The output power of the battery charger is out of range.· Other
    Check soon

    Causes

    • Output cable damaged
    • Charger failure

    Checks

    1. 1Check the output cable and battery connection
    2. 2Measure the charger output voltage
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 521Battery charger external or environmental fault

    The charger reports an external or environmental cause such as heat or a wiring fault outside the charger.· Other
    Check soon

    Causes

    • High ambient temperature
    • Wiring fault

    Checks

    1. 1Check the charger surroundings and wiring
    2. 2Let it cool and recheck
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 522Battery temperature sensor alarm

    The battery temperature sensor used by the charger gives an out-of-range reading.· Other
    Check soon

    Causes

    • Sensor wire damaged
    • Sensor failed

    Checks

    1. 1Check the sensor wire and plug
    2. 2Measure the sensor resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 523Battery charger indicated conditions

    The charger reports a general condition that the controller flags as an alarm.· Other
    Check soon

    Causes

    • Charger internal condition
    • Supply fault

    Checks

    1. 1Read the charger status and codes
    2. 2Check the supply
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 528Failed J1939 CAN communication base controller to charger

    The controller and the battery charger cannot talk over the J1939 CAN link.· Lost message
    Check soon

    Causes

    • CAN wire damaged
    • Charger supply lost

    Checks

    1. 1Check the CAN wires and plugs
    2. 2Check the charger supply
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Thermo King 542Battery charger fault: unit forced to low speed

    The battery charger has a fault that forces the unit to low speed.· Other
    Info

    Causes

    • Charger fault
    • Battery fault

    Checks

    1. 1Read the charger status
    2. 2Check the battery condition
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 543Battery charger internal short

    The battery charger reports an internal short circuit.· Short circuit
    Info

    Causes

    • Charger internal fault
    • Water in the charger

    Checks

    1. 1Check the charger for damage
    2. 2Replace the charger if the alarm remains
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • Thermo King 544Battery charger external short

    The battery charger reports a short circuit outside the charger on the output side.· Short circuit
    Info

    Causes

    • Output cable shorted
    • Battery terminal shorted

    Checks

    1. 1Check the output cable and terminals for shorts
    2. 2Measure the output resistance
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Key off, unplug the part and the controller. Measure from the output wire to ground and to battery positive, then across the part.

    Good: Open circuit (OL) to ground and to supply; the part reads its listed resistance, not near 0 Ω.

  • Thermo King 545Battery charger output voltage exceeded limit

    The battery charger output voltage went above its limit.· Real condition
    Info

    Causes

    • Charger regulator fault
    • Battery disconnected during charging

    Checks

    1. 1Check the battery connection
    2. 2Measure the charger output voltage
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Thermo King 546Battery charger operating bulk voltage out of range

    The bulk charging voltage of the charger is outside its range.· Other
    Info

    Causes

    • Charger regulator fault
    • Poor battery connection

    Checks

    1. 1Measure the charger bulk voltage
    2. 2Check the battery connection
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 548Battery charger temperature below operating range

    The temperature of the battery charger is below its operating range, as in cold weather.· Other
    Info

    Causes

    • Very low ambient temperature
    • Temperature sensor fault

    Checks

    1. 1Check the ambient temperature
    2. 2Check the charger sensor
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 549Battery charger AC input overvoltage

    The AC voltage to the charger is above its limit.· Other
    Info

    Causes

    • Supply voltage too high
    • Generator or site supply fault

    Checks

    1. 1Measure the AC supply voltage
    2. 2Check the source of the supply
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 550Battery charger internal overvoltage fault

    The charger detected an overvoltage inside itself.· Other
    Check soon

    Causes

    • Charger internal fault
    • Battery connection loose

    Checks

    1. 1Check the battery connection
    2. 2Replace the charger if the fault returns
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 551Battery charger internal temperature sensor fault

    The temperature sensor inside the charger is faulty.· Other
    Info

    Causes

    • Sensor failed
    • Charger internal fault

    Checks

    1. 1Check the charger for other alarms
    2. 2Replace the charger if the alarm remains
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 552Battery charger charging, low battery

    The charger reports that it is charging a low battery.· Other
    Info

    Causes

    • Battery discharged
    • Battery weak

    Checks

    1. 1Let the battery charge and recheck
    2. 2Test the battery
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Thermo King 553Battery charger operating derated due to high temperature

    The charger reduces its output because it is hot.· Real condition
    Info

    Causes

    • High ambient temperature
    • Charger cooling blocked

    Checks

    1. 1Check the charger cooling
    2. 2Allow it to cool
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Measure the battery voltage at rest and with the engine running
  2. 2Check the supply voltage at the charger input with a meter
  3. 3Check the output cable and terminals for shorts
  4. 4Check the ambient temperature around the charger
  5. 5Check the drive belt and the battery terminals
  6. 6Check the output cable and battery connection for corrosion
  7. 7Check the battery connection is secure and clean

Causes

  • Weak battery
  • Supply cable damaged
  • Short in the output
  • Extreme temperature

Most common here: shorted low (2 of 22)

Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.

When to stop

You'll notice: Low battery or alternator alarms and, in the worst case, the engine not starting.

Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.