Skyjack · On-board battery charger codes
Skyjack On-board battery charger codes fault codes
This page covers the on-board battery charger: its internal F-0-0-x faults, the E-0-0-x charge errors and what the LED blink patterns mean. The on-board charger shows F-0-0-x for faults found inside its own power stages: the DC-DC (LLC) converter, the PFC input stage, the DC relay and the current sensing.
More about these partsLess
The charger shows E-0-0-x when the charge cycle itself cannot start or finish: battery voltage out of range, a time or amp-hour limit reached, or a trickle charge that fails. On the operating-manual charger the three charge-state LEDs blink in patterns to report a connection, AC supply, temperature or current problem, and a blinking 100 percent LED reports the 18 hour timer.
Where this code shows
Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).
What do these codes mean?
Skyjack codes E-0-0-1 to 100% LED blinking are all about the on-board battery charger codes. The most common failure type is shorted low (2 of 16); 6 need an immediate stop. Start with this check: disconnect AC and the battery from the charger for at least 30 seconds, then reconnect.
How urgent are they?
6 of 16 codes here mean stop now; the other 10 can wait until the shift ends, but find the cause before the next one.
- Stop now6
- Check soon10
What should I check first?
Disconnect AC and the battery from the charger for at least 30 seconds, then reconnect
Shared checks16 of 16
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Skyjack E-0-0-1Charger error: battery voltage over limit
The charger saw battery voltage above its software limit at the start of a charge cycle, typically 2.5 V per cell on lead-acid batteries. Skyjack says this clears itself once the voltage is back in range.· Part or controllerPart or controllerCheck soonCauses
- Batteries already fully charged or just charged
- Charger voltage model does not match the battery pack
- Poor battery connection giving a false high reading
Checks
- 1Check the battery voltage and cable connections at the charger output
- 2Confirm the charger voltage rating suits the battery pack
- 3Let the batteries rest after a recent charge and try again
- 4Check that no battery of the wrong voltage has been fitted
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F-0-0-1Charger fault: DC-DC (LLC) excessive leakage
The charger's DC-DC stage reported excessive leakage in its LLC section and shut itself down. Skyjack lists this as an internal charger fault, so the fix is a power reset first and the charger itself if it returns.· OtherOtherStop nowCauses
- Failed component in the charger's DC-DC (LLC) power stage
- A one-off fault that clears with a power reset
- Damp or contaminated charger board
Checks
- 1Unplug the AC supply and disconnect the battery from the charger
- 2Leave both disconnected for at least 30 seconds, as the manual says
- 3Reconnect and start a charge to see if F-0-0-1 returns
- 4Look inside the charger area for water, dirt or heat damage
- 5If it returns, contact Skyjack service for a replacement charger
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack E-0-0-2Charger error: battery voltage too low to start
The battery voltage is below the level needed to start a charge, typically 0.1 V per cell. The error clears itself once the condition is corrected.· Shorted lowShorted lowCheck soonCauses
- Batteries deeply discharged
- Battery cable disconnected or loose
- Charger voltage does not match the batteries
- Dead cell in the pack
Checks
- 1Check the battery voltage and cable connections at the charger output
- 2Check the charger is the correct voltage for the battery pack
- 3Check battery size and condition; use another charger to lift an over-discharged pack above the minimum
- 4Wait for the error to clear after the fix, as it resets itself
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Skyjack F-0-0-2Charger fault: PFC excessive leakage
The charger's power factor correction (PFC) stage detected excessive leakage and tripped. It is the PFC counterpart of F-0-0-1, and Skyjack gives the same reset-and-contact-service action.· OtherOtherStop nowCauses
- Failed component in the PFC stage on the AC input side
- One-off fault caused by a supply surge
- Moisture inside the charger
Checks
- 1Disconnect AC and the battery from the charger for at least 30 seconds
- 2Check the AC supply and plug for burn marks or a damaged cord
- 3Reconnect and start a charge to see if the fault returns
- 4Check the AC source voltage is steady with a meter
- 5Contact Skyjack service if the code comes back
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack E-0-0-3Charger error: charge time limit reached
The charger ran for its maximum time without the batteries finishing. Skyjack lists reduced output from heat or low AC, damaged cells, tired batteries and extra loads as causes. It resets by cycling DC or losing AC for over 10 minutes.· OtherOtherCheck soonCauses
- Output reduced by heat or low AC voltage
- Shorted or damaged cell, or a tired battery
- Batteries too large for the charger
- Loose or corroded connection or a parasitic load on the batteries
Checks
- 1Check the ambient temperature and AC voltage during charging
- 2Check for shorted or damaged cells and the battery health
- 3Check the batteries are not too large for the charger
- 4Check the battery connections for looseness or corrosion
- 5Turn off any other device running from the batteries
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack F-0-0-3Charger fault: PFC took too long to boost
The PFC stage did not reach its boost voltage in the time allowed. The cause can be low or unstable AC input or an internal PFC fault.· Lost messageLost messageStop nowCauses
- Weak or unstable AC supply
- Long extension lead dropping the voltage
- Failed PFC stage inside the charger
Checks
- 1Measure the AC voltage at the socket the charger is plugged into
- 2Remove any long or thin extension lead and plug in directly
- 3Disconnect AC and the battery for 30 seconds, then retry the charge
- 4Try a different outlet on another circuit to rule out the supply
- 5Contact Skyjack service if the fault persists on a good supply
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Skyjack E-0-0-4Charger error: batteries could not be trickle charged
The battery could not be brought up to the minimum voltage by trickle charge. It can also be a general battery fault depending on the algorithm.· Lost messageLost messageCheck soonCauses
- Shorted or damaged cell
- Battery worn out
- Poor DC connections
- High charger temperature cutting the output
Checks
- 1Check for shorted or damaged cells in the pack with a hydrometer or load test
- 2Replace the battery if its health is poor after testing it
- 3Check the DC connections for looseness or corrosion
- 4Check the charger is not overheating, which cuts its output
- 5Note that some new batteries trigger it as their voltage dips when charging starts
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Skyjack F-0-0-4Charger fault: current offset calibration failed
The charger could not calibrate its current offset at start-up. Skyjack lists it as an internal fault, so after a reset it points at the charger electronics.· Part or controllerPart or controllerStop nowCauses
- Failed current sensing inside the charger
- Charger started with the battery connected in an unusual state
- Internal board fault
Checks
- 1Disconnect AC and the battery for at least 30 seconds
- 2Reconnect the battery first, then AC, and start a charge
- 3Check the battery cable connections are clean and tight
- 4Contact Skyjack service if it repeats after the reset
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Skyjack F-0-0-5Charger fault: DC relay voltage drop too high
The charger measured too much voltage drop across its DC output relay while the relay was closed. The relay contacts or its connections are not passing current cleanly.· Real conditionReal conditionStop nowCauses
- Worn or burnt DC relay contacts inside the charger
- Poor connection on the charger's DC output
- Internal board fault
Checks
- 1Disconnect AC and the battery for at least 30 seconds, then retry the charge
- 2Check the DC output cables and battery terminals are clean and tight
- 3Look for heat discolouration on the charger output lead and plug
- 4Contact Skyjack service if the code repeats after the reset
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Skyjack F-0-0-6Charger fault: DC-DC and battery sense currents differ
The charger saw a large difference between the current measured inside its DC-DC stage and the current measured at the battery sense. That points at a current-sense fault or a bad connection at the battery.· OtherOtherStop nowCauses
- Loose or corroded battery connection upsetting the sense reading
- Failed current sensing inside the charger
- Damaged sense wire
Checks
- 1Disconnect AC and the battery for at least 30 seconds, then retry
- 2Clean and tighten both battery cable terminals at the batteries
- 3Inspect the charger output lead for damage or a loose crimp
- 4Contact Skyjack service if it repeats after the reset
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack E-0-0-7Charger error: amp-hour limit reached
The charger reached its limit for amp-hours delivered. The causes match E-0-0-3, and it resets by cycling DC or by losing AC for over 10 minutes.· OtherOtherCheck soonCauses
- Output cut back by heat or low AC volts, so the amp-hours ran out first
- Shorted or damaged cells soaking up the charge
- Deeply discharged battery needing more than the allowed amp-hours
- Loose or corroded connection or an extra load drawing from the pack
Checks
- 1Check ambient temperature and AC voltage while it charges
- 2Check for shorted or damaged cells in the pack
- 3Retry charging a deeply discharged battery after a rest
- 4Check connections for looseness or corrosion at both ends
- 5Turn off any other devices running from the batteries
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 3 LEDs, 1 blinkCharger LEDs: 3 blinks, output connection error
All three charge-state LEDs blink once together. The charger cannot see a proper battery connection, or the output is shorted or reversed.· OtherOtherCheck soonCauses
- Charger not connected to the battery or connection loose
- Corroded battery terminals
- Output shorted by pinched wires
- Battery connected in reverse polarity
Checks
- 1Check the battery and charger connection at both ends
- 2Look for corrosion on the battery terminals and clean it off
- 3Check the cables for pinching or damage along their length
- 4Check the polarity of the connection to the battery
- 5Remember the charger itself is not damaged by these faults
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 3 LEDs, 2 blinkCharger LEDs: 2 blinks, AC voltage out of range
All three LEDs blink twice together; the charger is saying the AC input voltage is too low or too high.· Shorted lowShorted lowCheck soonCauses
- Low AC voltage at the supply
- High AC voltage at the supply
- Long or thin extension lead dropping the voltage
Checks
- 1Measure the AC voltage at the socket with a meter
- 2Remove any extension lead and plug in directly to the wall
- 3Try another outlet on a different circuit to rule out the supply
- 4Check the charger voltage setting matches the supply
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
Good: Open circuit (OL) to ground. A low reading means chafed insulation touching metal.
Skyjack 3 LEDs, 3 blinkCharger LEDs: 3 blinks, charger overheated
All three LEDs blink three times together because the charger is too hot. Skyjack says no action is needed as charging restarts when it cools.· Real conditionReal conditionCheck soonCauses
- Dirt or debris blocking the cooling fins
- High ambient temperature
- Charger in an enclosed space
Checks
- 1Wait for the charger to cool and restart by itself
- 2Clean dirt and debris from the charger cooling fins
- 3Move the machine to a cooler place to charge it
- 4Check airflow around the charger is not blocked
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Skyjack 3 LEDs, 4 blinkCharger LEDs: 4 blinks, over-current
All three LEDs blink four times together, an input or output over-current. Skyjack says no action is needed because the charger corrects and restarts by itself.· OtherOtherCheck soonCauses
- Momentary input or output over-current
- Fault in the battery connection
- Supply surge
Checks
- 1Wait for the charger to restart by itself after the over-current
- 2Check the battery connection is tight at both ends
- 3Check the AC supply voltage is steady with a meter
- 4Contact service if it keeps repeating after restarts
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Skyjack 100% LED blinkingCharger LEDs: 100% LED blinking, 18 hour timer
Only the 100% LED blinks. The charger's 18 hour timer ran out, which Skyjack says is due to a battery problem.· OtherOtherCheck soonCauses
- Worn or damaged battery
- Shorted cell
- Loose battery connection
- Battery too large for the charger
Checks
- 1Check the battery condition and test each cell
- 2Check the connections for looseness or corrosion
- 3Load test the batteries to see if they hold charge
- 4Replace the battery if it will not hold charge
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Disconnect AC and the battery from the charger for at least 30 seconds, then reconnect
- 2Measure the battery voltage and each battery in the string
- 3Check the battery and AC connections at both ends of each lead
- 4Check the AC supply and plug for burn marks or damage
- 5Check battery cables and terminals for corrosion and looseness
- 6Measure the AC supply voltage at the plug end
- 7Check the DC cable and battery connections for looseness
Causes
- Failed component inside the charger
- Battery voltage too low or too high
- Battery or AC connection loose
- Supply surge or poor AC supply
Most common here: shorted low (2 of 16)
Key off, unplug both ends. Measure resistance from the signal wire to ground and to the machine frame.
When to stop
You'll notice: The charger stops and shows an F-0-0-x fault.
Let the engine cool before opening the cooling system; a hot cap releases scalding coolant. Running on with an overheat warning risks a head gasket or seized engine.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Sources
- Skyjack SJIII 3220/3226/4620/4626/4632 Service Manual 157928AM (Apr 2019), section 5 Charger Troubleshooting, pp. 133-135
- Skyjack SJIII DC Electric Scissors Operating Manual 194849AGA (Nov 2022), section 3, battery charger, p. 57
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.