Skyjack · GP102 module LED flash codes
Skyjack Fault Code 6‑1
Height not calibrated
What does Skyjack code 6-1 mean?
The module has no valid height calibration stored, so it does not trust the height sensor. The manual says an EZcal is required. Urgency: check soon - the machine may derate or limit a function. Check first: confirm the height sensor and its wiring are good before calibrating anything.
Can I keep running with it?
Check soon
The machine may derate or limit a function. Find the cause before the next shift.
What should I check first?
Confirm the height sensor and its wiring are good before calibrating anything
Then 4 more checksWhere this code shows
Find the LED on the GP102 module (older SJIII scissors) or the display and keypad in the hydraulic tray (Skycoded machines).
Checks
0 of 5 done
Causes
- Controller replaced or reset
- Height sensor replaced
- Calibration data lost
- Calibration aborted part way
How it failed
You'll notice: Lift or drive may be limited and the LED shows six flashes then one.
Part or controllerRead from how the source describes the code
The controller reports a part, module or its software as faulty or not responding.
- Meter test
- Check power and ground at the module connector with the key on, then its fuses.
- Good result
- Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
When to stop
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Same part, other failures: Load and height sensors and load calibration
18 other codes on this part are also part or controller (F01, F03, F04, F05 and more). When they show together, start at the wiring and connector they share.
- F02Calibration F02: not in ground modeLost messageInformation
- F03Calibration F03: not stoppedPart or controllerInformation
- F04Calibration F04: tiltedPart or controllerCheck soon
- F05Calibration F05: bad height at startPart or controllerCheck soon
- 6-1Height not calibratedPart or controllerCheck soon
- 6-2Load not calibratedPart or controllerCheck soon
- 6-3No last calibration datePart or controllerCheck soon
- 6-4Invalid load, check sensorsOtherCheck soon
- 6-5Invalid height, check sensorOtherCheck soon
Show the other 16 codesHide the other codes
- F01Calibration F01: check HWFSPart or controllerInformation
- 6-6Overload functions disabledReal conditionInformation
- 6-7Factory overrideOtherInformation
- F09Calibration F09: bad height at start (second check)Lost messageCheck soon
- F10Calibration F10: bad height at endPart or controllerCheck soon
- F11Calibration F11: not upPart or controllerInformation
- F13Calibration F13: low height rangePart or controllerCheck soon
- F20Calibration F20: height not 0 percentPart or controllerCheck soon
- F28Calibration F28: bad height during runPart or controllerCheck soon
- F42Calibration F42: low pressure at startPart or controllerCheck soon
- F43Calibration F43: high pressure at startPart or controllerCheck soon
- F44Calibration F44: low pressure at a measurement pointPart or controllerCheck soon
- F45Calibration F45: high pressure at a measurement pointPart or controllerCheck soon
- F48Calibration F48: bad pressure at startPart or controllerCheck soon
- F52Calibration F52: too few measurementsPart or controllerCheck soon
- F98Calibration F98: fine tune out of rangePart or controllerCheck soon
Other Skyjack codes: GP102 module LED flash codes
Source
This source lists 6-1 and its meaning. The guidance on this page is general, not taken from it.
The source covers: Skyjack SJIII 3215 and 3219 DC electric scissors with the GP102 module (manual 155147AD, serials 10,000,574-10,000,630 and 22,019,597-22,022,792); later serial ranges can differ, check your own manual.
Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.