EF Logo

JLG · Platform / ground controls

JLG Function switches stuck selected (jib, telescope, tower lift, lift, swing, platform level, platform rotate) fault codes

Each boom and platform movement has a pair of direction inputs read by the JLG module as simply on or off: jib lift up/down, telescope in/out, tower lift up/down, main lift up/down, swing left/right, platform level up/down and platform rotate left/right. With every control released, the controller expects every one of these inputs to be off.

More about these parts

If an input stays on it reports "permanently selected" and names the direction that is held. The manual lists several of these pairs under two code numbers; the analyzer shows which input is really closed.

FaultCheck2247JLG · Function switches stuck selected (jib, telescope, tower lift, lift, swing, platform level, platform rotate)
Code shows hereFAULT2247

Where this code shows

Turn the key on and watch the fault lamp or platform display.

What do these codes mean?

JLG codes 2247 to 23114 are all about the function switches stuck selected (jib, telescope, tower lift, lift, swing, platform level, platform rotate). None needs an immediate stop. Start with this check: with every control released, read the direction inputs in the analyzer and note which one shows selected; the message names the same direction.

How urgent are they?

None of the 24 codes here means stop now; all 24 can wait until the shift ends, but find the cause before the next one.

  • Check soon24

What should I check first?

With every control released, read the direction inputs in the analyzer and note which one shows selected; the message names the same direction

Shared checks

24 of 24

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • JLG 2247Platform rotate left permanently selected

    The platform rotate left switch input stays closed with the control released.· Other
    Check soon

    Causes

    • Rotate switch jammed on its left side by a damaged lever or dirt
    • Rotate left wire chafed where the platform harness is twisted at the rotator
    • Rotate switch pin pushed back so it touches its neighbour in the connector

    Checks

    1. 1With the basket clear of obstructions, see whether it drifts left while all controls are released
    2. 2Press rotate right and read the left input in the analyzer; if it stays on, unplug the console switch and test again
    3. 3Inspect the rotate left terminal in the console plug for a pin pushed back or touching the next pin
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2248Platform rotate right permanently selected

    The platform rotate right switch input stays closed with the control released.· Other
    Check soon

    Causes

    • Rotate switch stuck on its right side from a cracked actuator
    • Rotate right wire shorted to a supply wire in the platform console
    • Rotate right switch bridged by silicone or cleaner left in the housing

    Checks

    1. 1Watch whether the basket creeps right with everything released and the boom still
    2. 2Disconnect the rotate switch and read the right input; if it clears the switch is at fault, if it stays the wiring or module is
    3. 3Look inside the rotate switch for residue or sticky film and clean it before you replace anything
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2249Jib lift up permanently selected

    The jib lift up rocker input stays closed with the control released.· Other
    Check soon

    Causes

    • Jib up rocker with a bent actuator tab that no longer centres
    • Jib up wire pinched against a supply wire where it leaves the platform console
    • Jib rocker boot split so wash water reaches the contacts

    Checks

    1. 1Push the jib down rocker: if the jib will not come down while jib up reads selected, the up input is really held and not just a display fault
    2. 2Unplug the jib rocker at the console; a clear jib up input in the analyzer clears the switch, a held one sends you into the harness along the boom
    3. 3Hold the jib rocker half way and watch whether the input flickers; a flickering input means worn contacts, a steady one means a short
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2250Jib lift down permanently selected

    The jib lift down rocker input stays closed with the control released.· Lost message
    Check soon

    Causes

    • Jib down side of the rocker sticking after dirt or spilt drink got into the housing
    • Jib down input pulled to supply by a damaged pin in the console connector
    • Jib cable crushed where the console lid closes on it

    Checks

    1. 1Watch the jib with the boom stopped: a jib that creeps down with no switch touched means the input is held, a steady jib means a false reading
    2. 2Press the jib up rocker and see whether the down input drops out in the analyzer; a down input that never drops points at the wiring or module
    3. 3Wiggle the jib cable at the console hinge with the analyzer open and watch the down input for changes
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • JLG 2251Telescope in permanently selected

    The telescope in input stays closed with the controls released.· Other
    Check soon

    Causes

    • Telescope switch jammed on its in side by dirt or a broken return spring
    • Telescope in wire shorted to a supply wire inside the control box
    • Telescope handle on the ground station bent so it rests against its stop

    Checks

    1. 1With the boom clear and stationary, note whether it draws in with nothing touched; if it does, the input is truly held
    2. 2Command telescope out and see whether it overrides the held in input; if not, unplug the switch and read the input again
    3. 3Look at the telescope lever at rest and check it sits centred and not leaning on its in stop
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2252Telescope out permanently selected

    The telescope out input stays closed with the controls released.· Other
    Check soon

    Causes

    • Telescope switch stuck on its out side from a cracked actuator
    • Moisture inside the switch housing bridging the telescope out contacts
    • Telescope out wire rubbing through at the boom base cable guide

    Checks

    1. 1Keep clear of the boom end and check whether it slowly extends with every control released
    2. 2Operate telescope in and read the out input in the analyzer; one that stays selected while in is commanded is held at the switch or its wiring
    3. 3Follow the telescope out wire through the boom base cable guide and look for bare copper
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2257Tower lift up permanently selected

    The tower lift up input stays closed with the controls released.· Other
    Check soon

    Causes

    • Tower lift up contact held by a worn switch or lever on the ground or platform station
    • Tower lift up wire damaged where the harness crosses the tower pivot
    • Tower lift switch contacts welded after a short on the supply feed

    Checks

    1. 1Watch the tower section with the boom stationary for slow upward drift that matches the selected input
    2. 2Unplug the tower lift switch and read the input; if it still shows selected, trace the wire to the module through the tower pivot area
    3. 3Check the fuse feeding the tower lift switch and the switch contacts for burn marks
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2258Tower lift down permanently selected

    The tower lift down input stays closed with the controls released.· Other
    Check soon

    Causes

    • Tower lift down side of the switch sticking after dirt or water got in
    • Tower lift down input touched by a neighbouring feed wire in the control box
    • Tower down input touched by water that ran down the platform support

    Checks

    1. 1Check that the tower section is not slowly lowering by itself before you reset anything
    2. 2Press tower lift up and see whether the down input clears in the analyzer; if it stays selected, replace or bypass-test the switch
    3. 3Dry the tower lift connector at the base of the tower and see whether the input drops out
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2262Platform level up permanently selected

    The platform level up switch input stays closed with the control released.· Other
    Check soon

    Causes

    • Platform level rocker sticking on its up side after water entered the basket console
    • Level up wire pinched between the console and the lid hinge
    • Level rocker cap loose so it presses on the switch body

    Checks

    1. 1Look at the basket angle with the boom still: a basket slowly tilting up means the input is held
    2. 2Open the console and unplug the level switch to see whether the level up input clears in the analyzer
    3. 3Press and release the level rocker cap gently and see whether it hangs on the body of the switch
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2263Platform level down permanently selected

    The platform level down switch input stays closed with the control released.· Other
    Check soon

    Causes

    • Platform level rocker stuck down from a bent actuator
    • Level down input held high by a corroded pin at the platform module
    • Basket level switch wiring pulled tight when the console was tilted for service

    Checks

    1. 1Watch the basket pitch with the boom stopped; a basket nosing forward points to a held level down input
    2. 2Compare the level down input in the analyzer with the switch at rest, then with the connector unplugged
    3. 3Check the console harness has slack at the hinge and the level wires are not under tension
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2370Jib lift up permanently selected

    Same fault as 2249: the jib lift up input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the jib lift up input closed, as listed under 2249
    • The second listing 2370 appearing together with 2249 confirms one held input, not two

    Checks

    1. 1Work through the 2249 checks for the jib lift up input and clear the cause there
    2. 2After repair confirm both 2249 and 2370 stay off in the analyzer with every control released
    3. 3Compare the jib up lever feel against 2249 to see which listing the analyzer is raising
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2371Jib lift down permanently selected

    Same fault as 2250: the jib lift down input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the jib lift down input closed, as listed under 2250
    • The second listing 2371 appearing together with 2250 confirms one held input, not two

    Checks

    1. 1Work through the 2250 checks for the jib lift down input and clear the cause there
    2. 2After repair confirm both 2250 and 2371 stay off in the analyzer with every control released
    3. 3Note whether jib down is the input held when both listings appear
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2372Swing left permanently selected

    The swing left input stays closed with the controls released.· Other
    Check soon

    Causes

    • Swing stick or switch not returning to centre on its left side
    • Swing left wire shorted to a supply or neighbouring input in the turret harness
    • Swing stick gaiter torn so the left side contact collects dirt

    Checks

    1. 1Make sure the turret path is clear, then watch whether the boom drifts left with every control released
    2. 2Release the swing control and read both swing inputs in the analyzer; the left input that stays selected is the one to chase
    3. 3Check the swing stick gaiter for tears and the stick shaft for grit at the left end of its travel
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 2373Swing right permanently selected

    The swing right input stays closed with the controls released.· Other
    Check soon

    Causes

    • Swing control not returning to centre on its right side after a bent lever
    • Swing right input pulled high by water in the connector
    • Swing right wire pinched under the turret cover plate

    Checks

    1. 1Clear the turret path and check whether the boom slowly swings right with nothing touched
    2. 2Unplug the swing control and recheck the right input; a clear input means the control, a held one means the wiring or module
    3. 3Lift the turret cover plate and look for the swing right wire pinched under its edge
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23105Tower lift up permanently selected

    Same fault as 2257: the tower lift up input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the tower lift up input closed, as listed under 2257
    • The second listing 23105 appearing together with 2257 confirms one held input, not two

    Checks

    1. 1Work through the 2257 checks for the tower lift up input and clear the cause there
    2. 2After repair confirm both 2257 and 23105 stay off in the analyzer with every control released
    3. 3Check that tower lift up is the input shown held when both numbers appear
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23106Tower lift down permanently selected

    Same fault as 2258: the tower lift down input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the tower lift down input closed, as listed under 2258
    • The second listing 23106 appearing together with 2258 confirms one held input, not two

    Checks

    1. 1Work through the 2258 checks for the tower lift down input and clear the cause there
    2. 2After repair confirm both 2258 and 23106 stay off in the analyzer with every control released
    3. 3Check that tower lift down is the input shown held when both numbers appear
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23107Lift up permanently selected

    The lift up input stays closed with the controls released.· Other
    Check soon

    Causes

    • Lift stick or rocker not returning from its up side
    • Lift up wire chafed against a supply wire at the boom base
    • Lift stick spring broken so it parks slightly up from centre

    Checks

    1. 1With the platform empty and the boom clear, watch whether it rises slowly with every control released
    2. 2Command lift down; if the boom will not come down while lift up reads selected, the up input is truly held
    3. 3Check the lift stick rests exactly at centre and that its return spring is intact
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23108Lift down permanently selected

    The lift down input stays closed with the controls released.· Other
    Check soon

    Causes

    • Lift stick or rocker stuck on its down side
    • Lift down input held by a corroded pin in the module connector
    • Lift down contact held by a stuck lever on the ground station

    Checks

    1. 1Watch whether the boom settles with every control released; steady means a false reading
    2. 2Press lift up, read the down input and unplug the control if it stays selected
    3. 3Operate the ground station lift lever slowly and see whether it releases fully at the down end
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23109Telescope in permanently selected

    Same fault as 2251: the telescope in input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the telescope in input closed, as listed under 2251
    • The second listing 23109 appearing together with 2251 confirms one held input, not two

    Checks

    1. 1Work through the 2251 checks for the telescope in input and clear the cause there
    2. 2After repair confirm both 2251 and 23109 stay off in the analyzer with every control released
    3. 3Confirm the telescope in input in the analyzer matches the number shown
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23110Telescope out permanently selected

    Same fault as 2252: the telescope out input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the telescope out input closed, as listed under 2252
    • The second listing 23110 appearing together with 2252 confirms one held input, not two

    Checks

    1. 1Work through the 2252 checks for the telescope out input and clear the cause there
    2. 2After repair confirm both 2252 and 23110 stay off in the analyzer with every control released
    3. 3Confirm the telescope out input in the analyzer matches the number shown
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23111Platform level up permanently selected

    Same fault as 2262: the platform level up input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the platform level up input closed, as listed under 2262
    • The second listing 23111 appearing together with 2262 confirms one held input, not two

    Checks

    1. 1Work through the 2262 checks for the platform level up input and clear the cause there
    2. 2After repair confirm both 2262 and 23111 stay off in the analyzer with every control released
    3. 3Verify platform level up reads held in the analyzer under this number
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23112Platform level down permanently selected

    Same fault as 2263: the platform level down input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the platform level down input closed, as listed under 2263
    • The second listing 23112 appearing together with 2263 confirms one held input, not two

    Checks

    1. 1Work through the 2263 checks for the platform level down input and clear the cause there
    2. 2After repair confirm both 2263 and 23112 stay off in the analyzer with every control released
    3. 3Verify platform level down reads held in the analyzer under this number
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23113Platform rotate left permanently selected

    Same fault as 2247: the platform rotate left input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the platform rotate left input closed, as listed under 2247
    • The second listing 23113 appearing together with 2247 confirms one held input, not two

    Checks

    1. 1Work through the 2247 checks for the platform rotate left input and clear the cause there
    2. 2After repair confirm both 2247 and 23113 stay off in the analyzer with every control released
    3. 3Verify rotate left reads held in the analyzer under this number
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • JLG 23114Platform rotate right permanently selected

    Same fault as 2248: the platform rotate right input reads as held.· Other
    Check soon

    Causes

    • Whatever holds the platform rotate right input closed, as listed under 2248
    • The second listing 23114 appearing together with 2248 confirms one held input, not two

    Checks

    1. 1Work through the 2248 checks for the platform rotate right input and clear the cause there
    2. 2After repair confirm both 2248 and 23114 stay off in the analyzer with every control released
    3. 3Verify rotate right reads held in the analyzer under this number
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1With every control released, read the direction inputs in the analyzer and note which one shows selected; the message names the same direction
  2. 2Feel whether the switch springs back firmly to centre when you release it; a lazy or gritty return points at the switch itself
  3. 3Unplug the named switch and watch the input: if it clears, replace the switch; if it stays on, suspect the wiring or the module
  4. 4Look along the harness to the switch for rub points, pinched wires and green pins at the connector
  5. 5After the repair, operate both directions in the analyzer and cycle EMS before driving or raising the boom

Causes

  • A rocker, toggle or stick lever jammed in one direction by dirt, a bent actuator or a weak return spring
  • A switch wire pinched against a supply wire or a neighbouring input in the control box or boom harness
  • Moisture bridging the switch contacts inside the housing
  • A corroded or pushed-back pin in the module connector that holds the input high

When to stop

You'll notice: The named movement either runs without being asked, will not answer the opposite direction, or the controller locks that function or blocks other boom functions while the input stays on.

Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.