DPF outlet temperature sensor voltage high

What does SPN 3246 FMI 3 mean?

The DPF outlet temperature sensor signal reads above its valid range, which the ECM sees as a short to supply or an open signal line. Urgency: check soon - the machine may derate or limit a function. Check first: key on, engine off: read the DPF outlet temperature sensor in the service tool; a reading far below any real temperature, or at its minimum, means the ECM sees an open or high-voltage circuit.

FaultCheckSPN 3246FMI 3J1939 engine ECU
FMI 3
Voltage above normal or shorted high

Can I keep running with it?

Check soon

The machine may derate or limit a function. Find the cause before the next shift.

What should I check first?

Key on, engine off: read the DPF outlet temperature sensor in the service tool; a reading far below any real temperature, or at its minimum, means the ECM sees an open or high-voltage circuit

Then 4 more checks
Plug the service tool in hereDiagnosticport, 9-pin

Where to read it

Connect a J1939-capable scan tool to the 9-pin diagnostic port.

Checks

0 of 5 done

Causes

  • Open circuit between the DPF outlet temperature sensor and the ECM, so the ECM sees full pull-up voltage and reads an extremely cold temperature
  • Signal wire shorted to a battery-voltage or 5 V wire in the harness, or an open sensor return
  • Sensor lead broken near the filter outlet cone after the canister was moved or cleaned
  • Plug off or hanging loose after DPF service
1 more cause
  • Sensor boss damaged by over-tightening, leaving the element open

How it failed

You'll notice: The ECM cannot see the gas temperature leaving the particulate filter, so it cannot tell whether a regeneration is burning soot safely.

Shorted highRead from FMI 3: voltage above normal or shorted high

The signal sits at or near the supply voltage - more than a working sensor can send.

ControllerPartSupplySignalGround
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.
Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good result
Open circuit (OL) between them. Any low reading is the short.

When to stop

Repeated aftertreatment faults lead to an engine derate. Parked regenerations and dosing tests are run with the service tool; do not remove or bypass DPF or SCR parts.

Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Source

Cummins ISX15 2013-2018 fault codes list (Diesel Laptops)

This list shows SPN 3246 with FMI 3. The guidance on this page is general, not taken from it.

Checks, causes, the drawing and the meter test are general workshop guidance, not the maker's procedure. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.