Genie · Battery charger codes
Genie Charger internal, CAN and USB faults fault codes
These codes come from the charger itself rather than the battery: the internal faults F-0-0-1 to F-0-0-5 (Genie fault ID 135 type 8), the CAN bus link and battery module communication, internal reference and start-up failures, and the problems that appear while updating charger software or selecting a profile from a USB drive.
Where this code shows
Scissors: read the code on the platform LED display or the ground control LCD.
What do these codes mean?
Genie codes F-0-0-1 to E-0-3-7 are all about the charger internal, CAN and USB faults. The most common failure type is part or controller (9 of 19); none needs an immediate stop. Start with this check: unplug the charger from AC and from the battery for 30 seconds, reconnect and see whether the code returns.
How urgent are they?
None of the 19 codes here means stop now; all 19 can wait until the shift ends, but find the cause before the next one.
- Check soon19
What should I check first?
Unplug the charger from AC and from the battery for 30 seconds, reconnect and see whether the code returns.
Shared checks19 of 19
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Genie F-0-0-1Internal fault (DC-DC)
The charger reports an internal DC-DC fault. Codes F-0-0-2 to F-0-0-5 are handled the same way. The charger will not charge until the fault is cleared.· Part or controllerPart or controllerCheck soonCauses
- Internal charger DC-DC converter fault
- Charger input power surge or poor AC supply
- Overheated charger
Checks
- 1Disconnect AC and the battery for 30 seconds, then reconnect and try again.
- 2Check the AC supply voltage is steady and within the charger rating.
- 3Check the charger vents are clear and the unit is not hot.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie F-0-0-2PFC excessive leakage
The charger found an excessive leakage fault in its power factor correction stage. It is an internal fault (Genie fault ID 135, type 8) that stops charging.· Part or controllerPart or controllerCheck soonCauses
- PFC stage damaged inside the charger
- Surge or water damage to the charger
Checks
- 1Disconnect the AC input and battery pack for 30 seconds and try again.
- 2Replace the charger if the fault returns.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie F-0-0-3PFC takes too long to boost
The PFC stage inside the charger took too long to reach its boost voltage. It is an internal fault (Genie fault ID 135, type 8) that stops charging.· Part or controllerPart or controllerCheck soonCauses
- PFC stage weak or failing
- Poor AC supply feeding the charger
Checks
- 1Check the AC supply, then disconnect AC and battery for 30 seconds and retry.
- 2Replace the charger if the fault returns.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie F-0-0-4Unable to calibrate current offset
The charger could not calibrate its current measurement offset at start-up. It is an internal fault (Genie fault ID 135, type 8) that stops charging.· Part or controllerPart or controllerCheck soonCauses
- Current sensing circuit failed
- Charger electronics damaged
Checks
- 1Disconnect the AC input and battery pack for 30 seconds and retry.
- 2Replace the charger if the fault returns.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie F-0-0-5Output relay voltage too high when closed
The charger measured too high a voltage across its output relay while the relay was closed. It is an internal fault (Genie fault ID 135, type 8) that stops charging.· Shorted highShorted highCheck soonCauses
- Output relay contacts worn or welded
- Charger electronics damaged
Checks
- 1Disconnect the AC input and battery pack for 30 seconds and retry.
- 2Replace the charger if the fault returns.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug the sensor and the controller. Measure resistance from the signal wire to the supply wire and to battery positive.
Good: Open circuit (OL) between them. Any low reading is the short.
Genie E-0-1-6Software update failed
A software update on the charger did not complete (Genie fault ID 135, type 8).· Part or controllerPart or controllerCheck soonCauses
- USB drive formatted with wrong software
- Update interrupted
- Wrong profile for the battery type
Checks
- 1Confirm the USB flash drive is formatted with the correct software.
- 2Retry; contact Genie support if it continues to fail.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie E-0-1-7USB error
The USB flash drive is not connected correctly to the charger (Genie fault ID 265, type 21).· Open circuitOpen circuitCheck soonCauses
- USB drive not seated
- Damaged USB drive or port
Checks
- 1Remove and re-insert the USB flash drive.
- 2Use a different USB flash drive.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Key off, unplug both ends. Measure each wire end to end, then the part itself across its pins.
Good: Near 0 Ω on each wire. The part reads its listed resistance, not OL.
Genie E-0-1-8Slot CRC error
The charger found a CRC error in a software slot during an update (Genie fault ID 135, type 8).· Part or controllerPart or controllerCheck soonCauses
- Corrupt software file on the drive
- Update interrupted
Checks
- 1Confirm the USB flash drive is formatted with the correct software.
- 2Retry the update with a different drive.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie E-0-1-9Hardware does not support software
The charger hardware does not support the software version being programmed (Genie fault ID 135, type 29).· Part or controllerPart or controllerCheck soonCauses
- Software file meant for other charger hardware
- Wrong update package
Checks
- 1Confirm the software matches the charger model.
- 2Contact Genie Product Support if the update continues to fail.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie E-0-2-0No algorithm selected
No charge profile (algorithm) has been programmed into the charger (Genie fault ID 266, type 31).· OtherOtherCheck soonCauses
- Charger new or replaced and not programmed
- Profile lost after a failed update
Checks
- 1Program the charger for the proper battery profile.
- 2Disconnect AC and battery for 30 seconds and retry.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Genie E-0-2-4Failure to initialize
The charger failed to turn on correctly during start-up (Genie fault ID 135, type 8).· OtherOtherCheck soonCauses
- Charger electronics fault
- Unstable supply at start-up
Checks
- 1Disconnect AC input and battery pack for 30 seconds.
- 2Contact Genie Product Support if the code returns.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Genie E-0-2-6Script failure
A script failed while the charger software was being updated (Genie fault ID 135, type 8).· Part or controllerPart or controllerCheck soonCauses
- Corrupt update package
- Update interrupted
Checks
- 1Confirm the USB flash drive is formatted with the correct software.
- 2Retry; contact Genie support if it fails again.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie E-0-2-7USB over current fault
USB over current protection in the charger has tripped (Genie fault ID 265, type 21).· OtherOtherCheck soonCauses
- Faulty USB drive drawing too much current
- Damaged USB port
Checks
- 1Remove and re-insert the USB flash drive, or use a different drive.
- 2Disconnect AC and battery for 30 seconds and retry.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Genie E-0-2-8Charge profile incompatibility
The selected charge profile is not compatible with the charger software (Genie fault ID 266, type 21).· Part or controllerPart or controllerCheck soonCauses
- Wrong profile for this software
- Software not updated
Checks
- 1Update the charger software.
- 2Confirm the charger profile is programmed correctly.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Check power and ground at the module connector with the key on, then its fuses.
Good: Battery voltage on power, under 0.2 V drop on ground. Then it needs the service tool.
Genie E-0-2-9CAN bus error
The charger reports a CAN bus network error (Genie fault ID 135, type 18).· Lost messageLost messageCheck soonCauses
- CAN wiring fault
- CAN module not working
Checks
- 1Check the CAN bus connections.
- 2Check the CAN termination resistance is about 60 ohms.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Genie E-0-3-0COMM battery module error
The charger reports a CAN bus battery module error (Genie fault ID 135, type 8).· Lost messageLost messageCheck soonCauses
- Battery module not communicating
- CAN wiring fault
Checks
- 1Check the CAN bus connections to the battery module.
- 2Disconnect AC and battery for 30 seconds.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Genie E-0-3-1Vref for ADC measurements triggered alarm
The reference voltage used for the charger's measurements raised an alarm. It is an internal charger error (Genie fault ID 135, type 8).· OtherOtherCheck soonCauses
- Internal reference circuit fault
- Charger electronics damaged
Checks
- 1Disconnect AC input and battery pack for 30 seconds.
- 2Contact Genie Product Support if the code returns.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Genie E-0-3-2CAN bus heartbeat error
The charger lost the regular CAN heartbeat message (Genie fault ID 135, type 13).· Lost messageLost messageCheck soonCauses
- CAN wiring fault
- Battery module not functioning
Checks
- 1Check the CAN bus connections.
- 2Check the battery module is working.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Genie E-0-3-7CAN Open error
A CAN Open reprogramming of the charger failed (Genie fault ID 135, type 8).· Lost messageLost messageCheck soonCauses
- CAN Open software missing
- Reprogramming interrupted
Checks
- 1Download the CAN Open software.
- 2Reprogram the charger using a USB flash drive.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Shared checks
Checks, in order
- 1Unplug the charger from AC and from the battery for 30 seconds, reconnect and see whether the code returns.
- 2Check the CAN connector between the charger and the battery module for corrosion and loose pins.
- 3For a USB or software code, repeat the update with a known good drive and the profile that matches the charger hardware.
- 4If an internal fault returns after a reset, replace the charger.
Causes
- Charger internal electronics failure
- CAN link to the battery module interrupted
- Software update interrupted or wrong profile file on the USB drive
- Hardware that does not support the loaded software
Most common here: part or controller (9 of 19)
Check power and ground at the module connector with the key on, then its fuses.
When to stop
You'll notice: Charging stops with a solid red fault light for the F codes or an amber flashing error for the E codes; the charger may need a reset or reprogramming.
Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.
Machine down?
Get a replacement machine or a technician - suppliers in the UAE contact you.