Develon · Aftertreatment
Develon Wheel loader SCR and aftertreatment (E044-E059) fault codes
Selective catalytic reduction (reagent or urea) system entries: tank level and temperature, dosing unit, reagent pump and line heater, pressure and NOx sensor limits.
Where this code shows
Switch the key on and open the monitor fault or service menu on the gauge panel to see active codes.
What do these codes mean?
Develon codes E044 to E059 are all about the wheel loader SCR and aftertreatment (E044-E059). The most common failure type is real condition (3 of 14); none needs an immediate stop. Start with this check: check the reagent level and quality and note what you find before replacing any part.
How urgent are they?
None of the 14 codes here means stop now; all 14 can wait until the shift ends, but find the cause before the next one.
- Check soon14
What should I check first?
Check the reagent level and quality and note what you find before replacing any part.
Shared checks14 of 14
Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet
Develon E044Aftertreatment 1 SCR Catalyst Tank Level
Same failure as E051 on the aftertreatment 1 scr catalyst tank level, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 SCR Catalyst Tank Level'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 scr catalyst tank level or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 scr catalyst tank level connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E044 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E047Aftertreatment 1 SCR Catalyst Tank Temperature
Same failure as E051 on the aftertreatment 1 scr catalyst tank temperature, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 SCR Catalyst Tank Temperature'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 scr catalyst tank temperature or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 scr catalyst tank temperature connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E047 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E048Aftertreatment 1 Outlet NOx
Same failure as E051 on the aftertreatment 1 outlet nox, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 Outlet NOx'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 outlet nox or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 outlet nox connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E048 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E049Aftertreatment 1 Exhaust Gas Temperature 1
Same failure as E051 on the aftertreatment 1 exhaust gas temperature 1, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 Exhaust Gas Temperature 1'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 exhaust gas temperature 1 or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 exhaust gas temperature 1 connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E049 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E050Aftertreatment 1 SCR Catalyst Tank Controller
Same failure as E051 on the aftertreatment 1 scr catalyst tank controller, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 SCR Catalyst Tank Controller'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 scr catalyst tank controller or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 scr catalyst tank controller connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E050 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E051Aftertreatment 1 SCR Catalyst Dosing Unit
The SCR dosing unit meters reagent into the exhaust. A fault here stops NOx reduction, so the controller can limit torque or speed.· Lost messageLost messageCheck soonCauses
- Faulty dosing unit or pump
- Frozen or blocked line
- Wiring fault
- Empty or poor reagent
Checks
- 1Check the reagent level and quality.
- 2Check the dosing line and heater for ice or blockage.
- 3Inspect the connector and wiring at the unit.
- 4Read the reagent pressure in the tool.
Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end. Meter test
Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.
Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.
Develon E052Aftertreatment 1 SCR Catalyst Tank Heater
Same failure as E051 on the aftertreatment 1 scr catalyst tank heater, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 SCR Catalyst Tank Heater'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 scr catalyst tank heater or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 scr catalyst tank heater connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E052 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E053NOx limits exceeded, root cause unknown
Same failure as E051 on the nox limits exceeded, root cause unknown, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'NOx limits exceeded, root cause unknown'.· Real conditionReal conditionCheck soonCauses
- Fault in the nox limits exceeded, root cause unknown or its wiring
- Any cause listed under E051
Checks
- 1Check the nox limits exceeded, root cause unknown connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E053 returns on its own.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Develon E054NOx limits exceeded due to Interrupted Reagent Dosing
Same failure as E051 on the nox limits exceeded due to interrupted reagent dosing, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'NOx limits exceeded due to Interrupted Reagent Dosing'.· Real conditionReal conditionCheck soonCauses
- Fault in the nox limits exceeded due to interrupted reagent dosing or its wiring
- Any cause listed under E051
Checks
- 1Check the nox limits exceeded due to interrupted reagent dosing connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E054 returns on its own.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Develon E055NOx limits exceeded due to Empty Reagent Tank
Same failure as E051 on the nox limits exceeded due to empty reagent tank, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'NOx limits exceeded due to Empty Reagent Tank'.· Real conditionReal conditionCheck soonCauses
- Fault in the nox limits exceeded due to empty reagent tank or its wiring
- Any cause listed under E051
Checks
- 1Check the nox limits exceeded due to empty reagent tank connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E055 returns on its own.
The reading against the band the controller allows. Meter test
Check the real value with a separate gauge or thermometer before blaming the sensor.
Good: If the gauge agrees with the display, fix the machine, not the sensor.
Develon E056Aftertreatment 1 SCR Dosing Reagent Absolute Pressure
Same failure as E051 on the aftertreatment 1 scr dosing reagent absolute pressure, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 SCR Dosing Reagent Absolute Pressure'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 scr dosing reagent absolute pressure or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 scr dosing reagent absolute pressure connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E056 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E057Aftertreatment 1 SCR Dosing Reagent Temperature
Same failure as E051 on the aftertreatment 1 scr dosing reagent temperature, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 SCR Dosing Reagent Temperature'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 scr dosing reagent temperature or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 scr dosing reagent temperature connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E057 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E058Aftertreatment 1 SCR Catalyst Reagent Line Heater 1 Preliminary FMI
Same failure as E051 on the aftertreatment 1 scr catalyst reagent line heater 1 preliminary fmi, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 SCR Catalyst Reagent Line Heater 1 Preliminary FMI'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 scr catalyst reagent line heater 1 preliminary fmi or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 scr catalyst reagent line heater 1 preliminary fmi connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E058 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Develon E059Aftertreatment 1 SCR Catalyst Reagent Pump Motor Speed
Same failure as E051 on the aftertreatment 1 scr catalyst reagent pump motor speed, a different part of the same kind as the aftertreatment 1 scr catalyst dosing unit. Specific to this code: the table names it 'Aftertreatment 1 SCR Catalyst Reagent Pump Motor Speed'.· OtherOtherCheck soonCauses
- Fault in the aftertreatment 1 scr catalyst reagent pump motor speed or its wiring
- Any cause listed under E051
Checks
- 1Check the aftertreatment 1 scr catalyst reagent pump motor speed connector and wiring first, then follow the checks listed under E051.
- 2Clear the code and confirm whether E059 returns on its own.
Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins. Meter test
Read the code with the service tool and note which other codes are active with it.
Good: Codes that appear together usually share one cause - start with the wiring they share.
Shared checks
Checks, in order
- 1Check the reagent level and quality and note what you find before replacing any part.
- 2Check the dosing line and heater for ice or blockage.
- 3Read NOx sensor and reagent pressure values and note what you find before replacing any part.
- 4Inspect the dosing unit and tank connectors and note what you find before replacing any part.
Causes
- Empty or contaminated reagent
- Frozen or blocked dosing line
- Faulty NOx sensor, pump or heater
- Wiring fault
Most common here: real condition (3 of 14)
Check the real value with a separate gauge or thermometer before blaming the sensor.
When to stop
You'll notice: Warning lamps, torque limit or a speed derate when reagent is empty, dosing is interrupted or NOx limits are exceeded.
Tilt, load and interlock cutouts are what keep a lift or telehandler from tipping. Never bypass or bridge one to keep working; get the fault found before anyone goes up or lifts again.
Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.
Related on Equipments Finder
Sources
Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.