EF Logo

Develon · Engine protection

Develon Engine protection, heaters, fan and starter fault codes

Engine protection logic (overspeed, performance limit, failed start), plus intake heater, glow, starter and fan clutch circuits. They are either protection triggers or on/off actuators with their own wiring.

FaultStopE000015Develon · Engine protection, heaters, fan and starter
Code shows hereFAULTE000015

Where this code shows

Switch the key on and open the monitor fault or service menu on the gauge panel to see active codes.

What do these codes mean?

Develon codes E000015 to E520648 are all about the engine protection, heaters, fan and starter. Most are real condition faults; 20 need an immediate stop. Start with this check: check basic engine condition (oil, coolant, air, fuel).

How urgent are they?

All 20 codes here mean stop now.

  • Stop now20

What should I check first?

Check basic engine condition (oil, coolant, air, fuel).

Shared checks

20 of 20

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Develon E000015Engine shut off request from EPOS

    Same failure as E000606 on the engine shut off request from epos, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the engine shut off request from epos or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the engine shut off request from epos connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000015 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000093Engine error lamp

    Same failure as E000606 on the engine error lamp, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the engine error lamp or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the engine error lamp connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000093 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000606Overspeed detection in component engine protection

    The overspeed monitor of engine protection triggered.· Real condition
    Stop now

    Causes

    • A real overspeed event (downhill load, driven wheels)
    • Faulty speed sensor signal
    • Wiring fault on the speed input

    Checks

    1. 1Review how the machine was being used when it happened.
    2. 2Check the crank and cam speed sensor readings for agreement.
    3. 3Inspect the sensor connectors and harness.
    4. 4Clear the code and check whether it returns.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000640Engine external protection input

    Same failure as E000606 on the engine external protection input, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the engine external protection input or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the engine external protection input connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000640 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000647FAN clutch control circuit

    Same failure as E000606 on the fan clutch control circuit, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the fan clutch control circuit or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the fan clutch control circuit connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000647 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000675Glow Plug Fault

    Same failure as E000606 on the glow plug fault, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the glow plug fault or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the glow plug fault connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000675 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000676Glow Relay Fault

    Same failure as E000606 on the glow relay fault, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the glow relay fault or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the glow relay fault connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000676 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000677Starter Cut Relay Fault

    Same failure as E000606 on the starter cut relay fault, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the starter cut relay fault or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the starter cut relay fault connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000677 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000729Intake air heater 1 circuit

    Same failure as E000606 on the intake air heater 1 circuit, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the intake air heater 1 circuit or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the intake air heater 1 circuit connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000729 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000977Auto fan clutch PWM out

    Same failure as E000606 on the auto fan clutch pwm out, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the auto fan clutch pwm out or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the auto fan clutch pwm out connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000977 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E000987Check Engine Lamp Fault

    Same failure as E000606 on the check engine lamp fault, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the check engine lamp fault or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the check engine lamp fault connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E000987 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E001639Auto fan clutch speed

    Same failure as E000606 on the auto fan clutch speed, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the auto fan clutch speed or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the auto fan clutch speed connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E001639 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E010030Starter Deterioration Warning

    Same failure as E000606 on the starter deterioration warning, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the starter deterioration warning or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the starter deterioration warning connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E010030 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E010031Starter Switch Fault

    Same failure as E000606 on the starter switch fault, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the starter switch fault or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the starter switch fault connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E010031 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E520610Power stage for intake air heater

    Same failure as E000606 on the power stage for intake air heater, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the power stage for intake air heater or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the power stage for intake air heater connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E520610 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E520613Vehicle cutoff switch error

    Same failure as E000606 on the vehicle cutoff switch error, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the vehicle cutoff switch error or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the vehicle cutoff switch error connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E520613 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E520615Performance limit activation

    Same failure as E000606 on the performance limit activation, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the performance limit activation or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the performance limit activation connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E520615 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E520625Detection of failed engine start

    Same failure as E000606 on the detection of failed engine start, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the detection of failed engine start or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the detection of failed engine start connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E520625 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E520643Monitoring of overrun

    Same failure as E000606 on the monitoring of overrun, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the monitoring of overrun or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the monitoring of overrun connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E520643 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

  • Develon E520648Monitoring of the engine protection

    Same failure as E000606 on the monitoring of the engine protection, a different part of the same kind as the overspeed detection in component engine protection.· Real condition
    Stop now

    Causes

    • Fault in the monitoring of the engine protection or its wiring
    • Any cause listed under E000606

    Checks

    1. 1Check the monitoring of the engine protection connector and wiring first, then follow the checks listed under E000606.
    2. 2Clear the code and confirm whether E520648 returns on its own.
    allowed rangetime
    The reading against the band the controller allows.

    Meter test

    Check the real value with a separate gauge or thermometer before blaming the sensor.

    Good: If the gauge agrees with the display, fix the machine, not the sensor.

Shared checks

Checks, in order

  1. 1Check basic engine condition (oil, coolant, air, fuel).
  2. 2Read companion codes for the trigger and note what you find before replacing any part.
  3. 3Test relays, heater and starter circuits for supply and ground.
  4. 4Check battery voltage under load and note what you find before replacing any part.

Causes

  • A real over-limit condition
  • Faulty relay, heater or switch
  • Wiring or supply fault

Most codes here: real condition (20 of 20)

Check the real value with a separate gauge or thermometer before blaming the sensor.

When to stop

You'll notice: The engine may derate, refuse to start or shut down; the lamp is on and the code is stored.

Most sensor and wiring faults can be traced with a multimeter and the wiring diagram. Disconnect the battery before unplugging controllers; if the controller itself is suspect or needs programming, that needs the dealer’s service tool.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.