EF Logo

Develon · Engine controller

Develon Engine controller and sensor supply voltage fault codes

Supply-voltage checks: battery voltage at the controller, the 5 V and 12 V sensor supply rails and the controller supply monitor. Low or noisy supply makes several sensors disagree at once.

FaultCheckE000158Develon · Engine controller and sensor supply voltage
Code shows hereFAULTE000158

Where this code shows

Switch the key on and open the monitor fault or service menu on the gauge panel to see active codes.

What do these codes mean?

Develon codes E000158 to E520644 are all about the engine controller and sensor supply voltage. None needs an immediate stop. Start with this check: measure battery voltage at rest, cranking and running against the 12-24 V system range.

How urgent are they?

None of the 13 codes here means stop now; all 13 can wait until the shift ends, but find the cause before the next one.

  • Check soon13

What should I check first?

Measure battery voltage at rest, cranking and running against the 12-24 V system range.

Shared checks

13 of 13

Stop nowshut down and fix before working onCheck soonfind the cause before the next shiftInfonothing is failing yet

  • Develon E000158Battery

    Battery voltage at the engine controller is outside the range it accepts.· Lost message
    Check soon

    Causes

    • Weak or sulphated battery
    • Charging fault at the alternator
    • Loose or corroded battery or ground connection
    • Voltage drop in the ECU supply fuse or relay

    Checks

    1. 1Measure battery voltage at rest, cranking and running against the 12-24 V system range.
    2. 2Check the battery terminals and the main ground for voltage drop under load.
    3. 3Test the alternator output with the engine running.
    4. 4Look at the ECU supply fuse and main relay for heat marks.
    Module AModule BCAN HCAN L120 Ω120 Ω
    Typical J1939 link: two modules, CAN high and low, a 120 Ω terminator at each end.

    Meter test

    Key off. Measure resistance between CAN high and CAN low at the diagnostic connector.

    Good: About 60 Ω on a two-terminator J1939 link. About 120 Ω means one terminator or one leg is open.

  • Develon E000168Battery voltage

    Same failure as E000158 on the battery voltage, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the battery voltage or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the battery voltage connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E000168 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E000627POWER SUPPLY

    Same failure as E000158 on the power supply, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the power supply or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the power supply connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E000627 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E0010795V Power Supply-6 Voltage Fault

    Same failure as E000158 on the 5v power supply-6 voltage fault, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the 5v power supply-6 voltage fault or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the 5v power supply-6 voltage fault connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E001079 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E0010805V Power Supply-2 Voltage Fault

    Same failure as E000158 on the 5v power supply-2 voltage fault, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the 5v power supply-2 voltage fault or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the 5v power supply-2 voltage fault connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E001080 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E003509Monitoring of 12V sensor supply voltage in ECU

    Same failure as E000158 on the monitoring of 12v sensor supply voltage in ecu, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the monitoring of 12v sensor supply voltage in ecu or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the monitoring of 12v sensor supply voltage in ecu connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E003509 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E003510Sensor supply 2 circuit

    Same failure as E000158 on the sensor supply 2 circuit, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the sensor supply 2 circuit or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the sensor supply 2 circuit connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E003510 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E003511Sensor supply 3 circuit

    Same failure as E000158 on the sensor supply 3 circuit, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the sensor supply 3 circuit or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the sensor supply 3 circuit connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E003511 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E0100095V Power Supply-3 Voltage Fault

    Same failure as E000158 on the 5v power supply-3 voltage fault, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the 5v power supply-3 voltage fault or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the 5v power supply-3 voltage fault connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E010009 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E0100105V Power Supply-4 Voltage Fault

    Same failure as E000158 on the 5v power supply-4 voltage fault, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the 5v power supply-4 voltage fault or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the 5v power supply-4 voltage fault connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E010010 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E0100115V Power Supply-5 Voltage Fault

    Same failure as E000158 on the 5v power supply-5 voltage fault, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the 5v power supply-5 voltage fault or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the 5v power supply-5 voltage fault connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E010011 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E01001212V Power Supply Voltage Fault

    Same failure as E000158 on the 12v power supply voltage fault, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the 12v power supply voltage fault or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the 12v power supply voltage fault connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E010012 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

  • Develon E520644Monitoring of voltage supply

    Same failure as E000158 on the monitoring of voltage supply, a different part of the same kind as the battery.· Other
    Check soon

    Causes

    • Fault in the monitoring of voltage supply or its wiring
    • Any cause listed under E000158

    Checks

    1. 1Check the monitoring of voltage supply connector and wiring first, then follow the checks listed under E000158.
    2. 2Clear the code and confirm whether E520644 returns on its own.
    ControllerPartSupplySignalGround
    Typical three-wire sensor or two-wire coil. Your wiring diagram has the real pins.

    Meter test

    Read the code with the service tool and note which other codes are active with it.

    Good: Codes that appear together usually share one cause - start with the wiring they share.

Shared checks

Checks, in order

  1. 1Measure battery voltage at rest, cranking and running against the 12-24 V system range.
  2. 2Check ECU supply fuses, main relay and grounds for voltage drop.
  3. 3Unplug sensors sharing the faulty rail one at a time to find a short.
  4. 4Inspect the alternator output and battery terminals.

Causes

  • Weak battery or poor charging
  • Short on a sensor harness loading the supply
  • High-resistance power or ground connection

When to stop

You'll notice: Several sensor codes may appear together; the engine may start hard or shut down on a weak battery.

Common-rail fuel runs at very high pressure. Never open a high-pressure line or fitting with the engine running or just after it stops - a fine fuel jet can pierce skin.

Each code above shows its own urgency. Call a technician if the checks above do not find the cause, if the code returns after clearing, or if the fix needs a service tool, a calibration or a software update.

Sources

Codes and meanings come from the sources above; short titles shorten the standard J1939 wording. Failure types, checks, meter tests and drawings are general workshop guidance, not the maker's. Codes can differ by serial number and software - confirm with the service manual or your dealer before replacing parts.

Machine down?

Get a replacement machine or a technician - suppliers in the UAE contact you.

Post a request
EquipmentsFinder

Need equipment? Have equipment?

Buyers post one request and get quotes from suppliers. Suppliers list free and reach active demand.